Ho-Yun Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ho-Yun Lee has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Mansoor Asif
Department of Electronic Engineering, Hanyang University, Hanyangdaehak-ro 55, Ansan 15588, Korea
11 shared publications - Bang-Wook Lee
Department of Electronic Engineering, Hanyang University, Ansan 15588, Republic of Korea
9 shared publications - Kyu-Hoon Park
Department of Electronic Engineering, Hanyang University, Hanyangdaehak-ro 55, Ansan 15588, Korea
7 shared publications Bang-Wook Lee
Division of Electronic Engineering, Hanyang University, Ansan, South Korea
6 shared publicationsJong-Geon Lee
Department of Electronics & System Engineering, Hanyang University, Ansan-si, Republic of Korea
4 shared publicationsUmer Amir Khan
Department of Electronics & System Engineering, Hanyang University, Ansan-si, Republic of Korea
3 shared publications
Latest Publications
- Open Access
Assessment of Overvoltage and Insulation Coordination in Mixed HVDC Transmission Lines Exposed to Lightning Strikes
Many geographical constraints and aesthetic concerns necessitate the partial use of cable sections in the High Voltage DC (HVDC) transmission line, resulting in a mixed transmission line. The overhead sections of mixed lines are exposed to lightning strikes. The lightning strikes can not only result in flashover of overhead line (OHL) insulators but can enter the cable and permanently damage its insulation if adequate insulation coordination measures are not taken. In this work, we have analyzed the factors that affect the level of overvoltage inside the cable by simulating a fast front model in PSCAD. It has been determined that surge arresters must be provided at cable terminals when the length of cable sections is less than 16 km to limit the core-ground overvoltage within the lightning impulse protective level (LIPL). The level of sheath-ground overvoltage is independent of the length of cable; however, it can be limited within LIPL by lowering the sheath grounding impedance to 1.2 Ω. Insulation coordination measures do not impact the likelihood of OHL insulators’ flashover. The flashover performance of OHL can be improved by lowering the footing impedance of the second tower closest to the cable terminals, which is otherwise most likely to flashover.
Open AccessAssessment of Overvoltage and Insulation Coordination in Mixed HVDC Transmission Lines Exposed to Lightning Strikes
Many geographical constraints and aesthetic concerns necessitate the partial use of cable sections in the High Voltage DC (HVDC) transmission line, resulting in a mixed transmission line. The overhead sections of mixed lines are exposed to lightning strikes. The lightning strikes can not only result in flashover of overhead line (OHL) insulators but can enter the cable and permanently damage its insulation if adequate insulation coordination measures are not taken. In this work, we have analyzed the factors that affect the level of overvoltage inside the cable by simulating a fast front model in PSCAD. It has been determined that surge arresters must be provided at cable terminals when the length of cable sections is less than 16 km to limit the core-ground overvoltage within the lightning impulse protective level (LIPL). The level of sheath-ground overvoltage is independent of the length of cable; however, it can be limited within LIPL by lowering the sheath grounding impedance to 1.2 Ω. Insulation coordination measures do not impact the likelihood of OHL insulators’ flashover. The flashover performance of OHL can be improved by lowering the footing impedance of the second tower closest to the cable terminals, which is otherwise most likely to flashover.
- Open Access
Accurate Evaluation of Steady-State Sheath Voltage and Current in HVDC Cable Using Electromagnetic Transient Simulation
The current and voltage in High Voltage DC (HVDC) line is not pure DC but contain superimposed ripple components. The current ripple in core of HVDC cable magnetically induces a voltage in the sheath, whereas the voltage ripple causes the flow of charging current from core to sheath. The knowledge of sheath voltage is necessary to ensure compliance with the specification of utility companies. In this work, we have reported that the models available in commercial Electromagnetic Transient (EMT) simulation software erroneously introduce a DC bias in steady-state sheath voltage and sheath current. We have also demonstrated that by removing the DC bias accurate steady-state evaluation of sheath voltage and sheath current is possible. Additionally, we have analyzed the sheath voltage and currents in HVDC cable considering different cable lengths and sheath grounding schemes. It has been found that grounding the sheath at the terminal of HVDC cable can limit the sheath voltage to acceptable levels without causing substantial joule loss in the sheath.
Open AccessAccurate Evaluation of Steady-State Sheath Voltage and Current in HVDC Cable Using Electromagnetic Transient Simulation
The current and voltage in High Voltage DC (HVDC) line is not pure DC but contain superimposed ripple components. The current ripple in core of HVDC cable magnetically induces a voltage in the sheath, whereas the voltage ripple causes the flow of charging current from core to sheath. The knowledge of sheath voltage is necessary to ensure compliance with the specification of utility companies. In this work, we have reported that the models available in commercial Electromagnetic Transient (EMT) simulation software erroneously introduce a DC bias in steady-state sheath voltage and sheath current. We have also demonstrated that by removing the DC bias accurate steady-state evaluation of sheath voltage and sheath current is possible. Additionally, we have analyzed the sheath voltage and currents in HVDC cable considering different cable lengths and sheath grounding schemes. It has been found that grounding the sheath at the terminal of HVDC cable can limit the sheath voltage to acceptable levels without causing substantial joule loss in the sheath.
- Open Access
Appropriate Protection Scheme for DC Grid Based on the Half Bridge Modular Multilevel Converter System
The half bridge (HB) modular multilevel converter (MMC) technology is considered a breakthrough to mitigate the shortcomings of the conventional voltage source converter (VSC) in high-voltage direct-current (HVDC) grid application. However, interruption of the DC fault is still a challenge due to fast di/dt and extremely high levels of DC fault current. The fault interruption using a DC circuit breaker (DCCB) causes enormous energy dissipation and voltage stress across the DCCB. Therefore, the use of a fault current limiter is essential, and the superconducting fault current limiter (SFCL) is the most promising choice. Past literature has focused on the operating characteristics of DCCB or limiting characteristics of the SFCL. However, there is little understanding about the fault interruption and system recovery characteristics considering both DCCB and SFCL. In this paper, we have presented a comparative study on fault interruption and system recovery characteristics considering three types of fault limiting devices in combination with circuit breaker. The transient analyses of AC and DC system have been performed, to suggest the most preferable protection scheme. It has been concluded that, amongst the three fault limiting devices, the Hybrid SFCL in combination with circuit breaker, delivers the most desirable performance in terms of interruption time, recovery time, energy dissipation and voltage transients.
Open AccessAppropriate Protection Scheme for DC Grid Based on the Half Bridge Modular Multilevel Converter System
The half bridge (HB) modular multilevel converter (MMC) technology is considered a breakthrough to mitigate the shortcomings of the conventional voltage source converter (VSC) in high-voltage direct-current (HVDC) grid application. However, interruption of the DC fault is still a challenge due to fast di/dt and extremely high levels of DC fault current. The fault interruption using a DC circuit breaker (DCCB) causes enormous energy dissipation and voltage stress across the DCCB. Therefore, the use of a fault current limiter is essential, and the superconducting fault current limiter (SFCL) is the most promising choice. Past literature has focused on the operating characteristics of DCCB or limiting characteristics of the SFCL. However, there is little understanding about the fault interruption and system recovery characteristics considering both DCCB and SFCL. In this paper, we have presented a comparative study on fault interruption and system recovery characteristics considering three types of fault limiting devices in combination with circuit breaker. The transient analyses of AC and DC system have been performed, to suggest the most preferable protection scheme. It has been concluded that, amongst the three fault limiting devices, the Hybrid SFCL in combination with circuit breaker, delivers the most desirable performance in terms of interruption time, recovery time, energy dissipation and voltage transients.
- Open Access
- 27 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 7194-7205
Analysis of Transient Behavior of Mixed High Voltage DC Transmission Line Under Lightning Strikes
Growing urbanization coupled with increased power demands have led to an increasing use of mixed power transmission lines with sections of overhead lines (OHL) and the underground cables. Due to differences in surge impedance of cables and OHL, voltage surges experience reflections and refractions at their boundaries which make the transient behavior of mixed high voltage direct current (HVDC) line quite peculiar. Lightning strikes on overhead sections of lines induce voltage surges that travel along OHL and enter the cable section. Lightning overvoltage can cause OHL insulators to flashover and stress cable insulation or cause its permanent breakdown. In this paper we simulated a fast front model of a mixed HVDC transmission line using an electromagnetic transient (EMT) simulation program (PSCAD) to analyze its transient behavior under a lightning strike. The leader progression model (LPM) has been used to predict the dielectric performance of OHL insulators. It has been shown that transition towers adjacent to the cable section are much less vulnerable to flashover than subsequent towers. The length of a riser section (connecting OHL and cable) and tower footing impedance have shown to significantly influence the flashover performance of OHL insulators. In addition, the length of cable segments and sheath grounding impedance have been found to influence cable overvoltage. This study can be used to evaluate the insulation coordination and overvoltage protection requirements for a mixed HVDC transmission line.
- 27 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 7194-7205
Open AccessAnalysis of Transient Behavior of Mixed High Voltage DC Transmission Line Under Lightning Strikes
Growing urbanization coupled with increased power demands have led to an increasing use of mixed power transmission lines with sections of overhead lines (OHL) and the underground cables. Due to differences in surge impedance of cables and OHL, voltage surges experience reflections and refractions at their boundaries which make the transient behavior of mixed high voltage direct current (HVDC) line quite peculiar. Lightning strikes on overhead sections of lines induce voltage surges that travel along OHL and enter the cable section. Lightning overvoltage can cause OHL insulators to flashover and stress cable insulation or cause its permanent breakdown. In this paper we simulated a fast front model of a mixed HVDC transmission line using an electromagnetic transient (EMT) simulation program (PSCAD) to analyze its transient behavior under a lightning strike. The leader progression model (LPM) has been used to predict the dielectric performance of OHL insulators. It has been shown that transition towers adjacent to the cable section are much less vulnerable to flashover than subsequent towers. The length of a riser section (connecting OHL and cable) and tower footing impedance have shown to significantly influence the flashover performance of OHL insulators. In addition, the length of cable segments and sheath grounding impedance have been found to influence cable overvoltage. This study can be used to evaluate the insulation coordination and overvoltage protection requirements for a mixed HVDC transmission line.
- Open Access
- 10 December 2018
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 2202-2206
Parameter identification of dc black‐box arc model using non‐linear least squares
The black‐box arc model is known to be a useful technique to simulate dynamic arc‐circuit interaction by reflecting arc characteristics. Existing researches have shown that the black‐box model has been widely used to analyse the ac arc characteristics of SF 6 and air circuit breakers. Due to the enormous energy and steep rise rate (d i /d t ) during dc fault, it is important to consider dc arc characteristics. However, there are no examples of black‐box models for dc circuit breakers utilised in railway systems and dc microgrid. In this study, the applicability of the black‐box model, which was applied to the existing ac arc analysis, was verified for the dc arc analysis. Black‐box modelling is applied to datasheet of industrial low‐voltage circuit breakers and parametric sweep method was used to select Schwarz model parameters considering the tendency of dc arc current waveform for the dc pole‐to‐pole fault. The authors also applied the Levenberg–Marquardt algorithm, which is the most extensively used for the optimisation of functional parameters, to the Schwarz model for accurate and reliable arc modelling. As a result, the dc arc feasibility of the black‐box model was analysed through simulation results, and a model optimisation technique was proposed.
- 10 December 2018
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 2202-2206
Open AccessParameter identification of dc black‐box arc model using non‐linear least squares
The black‐box arc model is known to be a useful technique to simulate dynamic arc‐circuit interaction by reflecting arc characteristics. Existing researches have shown that the black‐box model has been widely used to analyse the ac arc characteristics of SF 6 and air circuit breakers. Due to the enormous energy and steep rise rate (d i /d t ) during dc fault, it is important to consider dc arc characteristics. However, there are no examples of black‐box models for dc circuit breakers utilised in railway systems and dc microgrid. In this study, the applicability of the black‐box model, which was applied to the existing ac arc analysis, was verified for the dc arc analysis. Black‐box modelling is applied to datasheet of industrial low‐voltage circuit breakers and parametric sweep method was used to select Schwarz model parameters considering the tendency of dc arc current waveform for the dc pole‐to‐pole fault. The authors also applied the Levenberg–Marquardt algorithm, which is the most extensively used for the optimisation of functional parameters, to the Schwarz model for accurate and reliable arc modelling. As a result, the dc arc feasibility of the black‐box model was analysed through simulation results, and a model optimisation technique was proposed.
- Open Access
- 26 November 2018
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 767-770
Feasible protection strategy for HVDC system by means of SFCL and passive resonance DC breaker
The key obstacle in implementing high‐voltage direct current (HVDC) grid, which is considered as the future of power grid, is the absence of effective DC circuit breaker (DCCB). At present, HVDC grid could be based on half‐bridge (HB) or full‐bridge (FB) voltage source converter (VSC). Among these two converter topologies, FB topology has an advantage of reverse current blocking at a much higher cost compared to HB technology and still requires a DCCB for isolating the faulty line. Therefore, HB technology is more realistic to implement HVDC grid economically if DC fault current could be controlled more effectively. In this respect, this article suggests feasible fault protection strategy based on superconducting fault current limiter (SFCL) and passive resonance circuit breaker (PRCB) which could be applied effectively to HB system. To evaluate the performance of suggested protection scheme, comparative study of full‐bridge modular multilevel converter (FB‐MMC) protection was performed. In addition, the process to determine the optimal range for quenching resistance of SFCL was also investigated. Consequently, the authors’ suggested protection scheme has shown remarkably improved fault current limiting and interruption performance compared to FB‐MMC protection scheme.
- 26 November 2018
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 767-770
Open AccessFeasible protection strategy for HVDC system by means of SFCL and passive resonance DC breaker
The key obstacle in implementing high‐voltage direct current (HVDC) grid, which is considered as the future of power grid, is the absence of effective DC circuit breaker (DCCB). At present, HVDC grid could be based on half‐bridge (HB) or full‐bridge (FB) voltage source converter (VSC). Among these two converter topologies, FB topology has an advantage of reverse current blocking at a much higher cost compared to HB technology and still requires a DCCB for isolating the faulty line. Therefore, HB technology is more realistic to implement HVDC grid economically if DC fault current could be controlled more effectively. In this respect, this article suggests feasible fault protection strategy based on superconducting fault current limiter (SFCL) and passive resonance circuit breaker (PRCB) which could be applied effectively to HB system. To evaluate the performance of suggested protection scheme, comparative study of full‐bridge modular multilevel converter (FB‐MMC) protection was performed. In addition, the process to determine the optimal range for quenching resistance of SFCL was also investigated. Consequently, the authors’ suggested protection scheme has shown remarkably improved fault current limiting and interruption performance compared to FB‐MMC protection scheme.
- Open Access
- 6 October 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (10) , 1834
Assessment of Appropriate MMC Topology Considering DC Fault Handling Performance of Fault Protection Devices
The eventual goal of high-voltage direct-voltage (HVDC) systems is to implement HVDC grids. The modular multilevel converter (MMC) has been identified as the best candidate for the realization of an HVDC grid by eliminating the shortcomings of conventional voltage source converter (VSC) technology. The related research has focused on efficient control schemes, new MMC topologies, and operational characteristics of an MMC in a DC grid, but there is little understanding about the fault handling capability of two mainstream MMC topologies, i.e., half bridge (HB) and full bridge (FB) MMCs in combination with an adequate protection device. Contrary to the existing research where the fault location is usually fixed (center of the line), this paper considered a variable fault location on the DC line, so as to compare the fault interruption time and maximum fault current magnitude. From the point of view of fault interruption, AC and DC side transient analyses were performed for both MMC topologies to suggest the appropriate topology. The simulation result confirmed that the fault handling performance of an HB-MMC with a DC circuit breaker is superior due to the smaller fault current magnitude, faster interruption time, lower overvoltage magnitude, and lesser stresses on the insulation of the DC grid.
- 6 October 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (10) , 1834
Open AccessAssessment of Appropriate MMC Topology Considering DC Fault Handling Performance of Fault Protection Devices
The eventual goal of high-voltage direct-voltage (HVDC) systems is to implement HVDC grids. The modular multilevel converter (MMC) has been identified as the best candidate for the realization of an HVDC grid by eliminating the shortcomings of conventional voltage source converter (VSC) technology. The related research has focused on efficient control schemes, new MMC topologies, and operational characteristics of an MMC in a DC grid, but there is little understanding about the fault handling capability of two mainstream MMC topologies, i.e., half bridge (HB) and full bridge (FB) MMCs in combination with an adequate protection device. Contrary to the existing research where the fault location is usually fixed (center of the line), this paper considered a variable fault location on the DC line, so as to compare the fault interruption time and maximum fault current magnitude. From the point of view of fault interruption, AC and DC side transient analyses were performed for both MMC topologies to suggest the appropriate topology. The simulation result confirmed that the fault handling performance of an HB-MMC with a DC circuit breaker is superior due to the smaller fault current magnitude, faster interruption time, lower overvoltage magnitude, and lesser stresses on the insulation of the DC grid.
- 18 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (6) , 2999-3008
Influence of Placement of Overhead Ground Wires on Steady State Induction in AC-DC Hybrid Transmission Corridor
To meet the growing power demand of the future, utilities and researchers have considered the addition of dc circuits in existing transmission corridors. The previous research has focused on analyzing the field environment, steady state induction and the negative effects of induction in the hybrid transmission lines. The overhead ground wires (OHGWs) have been used only for improving the lightning performance of overhead lines (OHL). In this paper, the spatial position of OHGWs have been studied with the objective of minimizing the steady state induction between power conductors as well as poorly grounded metallic objects like railroads and fences present near the ac-dc OHL. Candidate space for placement of OHGWs having shielding failure rate (SFR) of less than 4 is identified using the conventional electro-geometric model (EGM). The steady state induction in the power conductors and nearby metallic objects is studied as a function of position of OHGWs using electro-magnetic transient (EMT) simulation. The results indicate a strong correlation between the height of OHGWs and magnitude of induced voltage in power conductors, and metallic objects underneath the transmission line. The conscious effort in placement of OHGWs can reduce the magnitude of induced voltages while ensuring adequate lightning performance.
- 18 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (6) , 2999-3008
Influence of Placement of Overhead Ground Wires on Steady State Induction in AC-DC Hybrid Transmission Corridor
To meet the growing power demand of the future, utilities and researchers have considered the addition of dc circuits in existing transmission corridors. The previous research has focused on analyzing the field environment, steady state induction and the negative effects of induction in the hybrid transmission lines. The overhead ground wires (OHGWs) have been used only for improving the lightning performance of overhead lines (OHL). In this paper, the spatial position of OHGWs have been studied with the objective of minimizing the steady state induction between power conductors as well as poorly grounded metallic objects like railroads and fences present near the ac-dc OHL. Candidate space for placement of OHGWs having shielding failure rate (SFR) of less than 4 is identified using the conventional electro-geometric model (EGM). The steady state induction in the power conductors and nearby metallic objects is studied as a function of position of OHGWs using electro-magnetic transient (EMT) simulation. The results indicate a strong correlation between the height of OHGWs and magnitude of induced voltage in power conductors, and metallic objects underneath the transmission line. The conscious effort in placement of OHGWs can reduce the magnitude of induced voltages while ensuring adequate lightning performance.
- 30 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (4) , 1-5
Feasible Application Study of Several Types of Superconducting Fault Current Limiters in HVDC Grids
The eventual goal of high-voltage direct-voltage (HVDC) systems is to implement HVDC grids. One of the key obstacles in realization of the HVDC grid is the absence of a dc circuit breaker (DCCB). Several prototypes of DCCBs for the HVDC grid have been proposed, but no commercial solution has been developed yet due to insufficient dc fault current breaking capabilities and an unreliable protection-coordination scheme. In this respect, application of the suitable fault current limiter is necessary, and the use of a superconducting fault current limiter (SFCL), which has already been developed for the ac grid, is a viable solution, but there is no fundamental research about performance evaluation of SFCLs for the dc grid. Therefore, we aim to verify the applicability of the conventional SFCL in HVDC grids and perform a comparative analysis of the performance of several types of SFCLs. To analyze the performance of the conventional SFCL in the HVDC grid, three well-known representative types of SFCLs are modeled in MATLAB/Simulink, and their current limiting and recovery characteristics and energy dissipation are examined in voltage-source converter HVDC system application. From the simulation results, we deduced the strengths and the weakness of different types of SFCLs. Consequently, the likely SFCL candidate for commercialization in dc grid applications is suggested.
- 30 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (4) , 1-5
Feasible Application Study of Several Types of Superconducting Fault Current Limiters in HVDC Grids
The eventual goal of high-voltage direct-voltage (HVDC) systems is to implement HVDC grids. One of the key obstacles in realization of the HVDC grid is the absence of a dc circuit breaker (DCCB). Several prototypes of DCCBs for the HVDC grid have been proposed, but no commercial solution has been developed yet due to insufficient dc fault current breaking capabilities and an unreliable protection-coordination scheme. In this respect, application of the suitable fault current limiter is necessary, and the use of a superconducting fault current limiter (SFCL), which has already been developed for the ac grid, is a viable solution, but there is no fundamental research about performance evaluation of SFCLs for the dc grid. Therefore, we aim to verify the applicability of the conventional SFCL in HVDC grids and perform a comparative analysis of the performance of several types of SFCLs. To analyze the performance of the conventional SFCL in the HVDC grid, three well-known representative types of SFCLs are modeled in MATLAB/Simulink, and their current limiting and recovery characteristics and energy dissipation are examined in voltage-source converter HVDC system application. From the simulation results, we deduced the strengths and the weakness of different types of SFCLs. Consequently, the likely SFCL candidate for commercialization in dc grid applications is suggested.