Abstract
To determine if residential water sampling corroborates the expectation that formation of stable PbO2 coatings on lead service lines (LSLs) provides an effective lead release control strategy, lead profile sampling was evaluated for eight home kitchen taps in three U.S. cities with observed PbO2-coated LSLs (Newport, Rhode Island; Cincinnati and Oakwood, Ohio). After various water standing times, these LSLs typically released similar or lower peak lead levels (1 to 18 μg/L) than the lead levels from the respective kitchen faucets (1 to 130 μg/L), and frequently 50–80% lower than the lead levels typically reported from Pb(II)-coated LSLs in comparable published sampling studies. Prolonged stagnation (10–101 h) at the Cincinnati sites produced varying results. One site showed minimal (0–4 μg/L) increase in lead release from the PbO2-coated LSL, and persistence of free chlorine residual. However, the other site showed up to a 3-fold increase proportional to standing time, with essentially full depletion of the chlorine residual. Overall, lead release was consistently much lower than that reported in studies of Pb(II)-coated LSL scales, suggesting that natural formation of PbO2 in LSLs is an effective lead “corrosion” control strategy.Keywords
Funding Information
- Office of Research and Development, U.S. Environmental Protection Agency
This publication has 17 references indexed in Scilit:
- Detection and Evaluation of Elevated Lead Release from Service Lines: A Field StudyEnvironmental Science & Technology, 2013
- Application of lead monitoring results to predict 0–7 year old children's exposure at the tapWater Research, 2013
- Potential Reversal and the Effects of Flow Pattern on Galvanic Corrosion of LeadEnvironmental Science & Technology, 2012
- Lead (Pb) in Tap Water and in Blood: Implications for Lead Exposure in the United StatesCritical Reviews in Environmental Science and Technology, 2012
- Effects of flow and water chemistry on lead release rates from pipe scalesWater Research, 2011
- Impact of Chlorine Disinfectants on Dissolution of the Lead Corrosion Product PbO2Environmental Science & Technology, 2010
- Effects of pH and Carbonate Concentration on Dissolution Rates of the Lead Corrosion Product PbO2Environmental Science & Technology, 2010
- Development of a convective diffusion model for lead pipe rigs operating in laminar flowWater Research, 2006
- Modelling the diffusion of lead into drinking waterApplied Mathematical Modelling, 2002
- Causes of temporal variability of lead in domestic plumbing systemsEnvironmental Monitoring and Assessment, 1990