A fractional motion diffusion model for a twice‐refocused spin‐echo pulse sequence
- 22 August 2018
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 31 (11) , e3960
Abstract
The purpose of this study was to develop an analytical expression for a fractional motion (FM) diffusion model to characterize diffusion‐induced signal attenuation in a twice‐refocused spin‐echo (TRSE) sequence that is resilient to eddy currents, and to demonstrate its applicability to human brain imaging in vivo. Based on the FM theory, which provides a unified statistical description for Langevin motions, the diffusion‐weighted (DW) MR signal was measured with a TRSE sequence that balances the concomitant gradients. The analytical expression was fitted to a set of DW images acquired with 14 b‐values (0–4000 s/mm2) from a total of 10 healthy human subjects at 3 T, yielding three FM parameter maps based on anomalous diffusion coefficient Dφ, ψ, diffusion increment variance φ, and diffusion correlation ψ, respectively. These parameters were used to characterize different brain regions in gray matter (GM), white matter (WM), and cerebrospinal fluid. The analytical expression for the TRSE‐based FM model accurately described diffusion signal attenuation in healthy brain tissues at high b‐values. TRSE's robustness against eddy currents was illustrated by comparing results from an expression for a conventional Stejskal‐Tanner sequence. The TRSE‐based FM model also produced consistent GM‐WM contrast (p < 0.01) across all brain regions studied, whereas the consistency was not observed with the Stejskal‐Tanner‐based FM model. This new analytical expression is expected to enable further investigations to probe tissue structures by exploiting anomalous diffusion properties without being hindered by eddy‐current perturbations at high b‐values.Keywords
Funding Information
- National Institutes of Health (1S10RR028898)
This publication has 55 references indexed in Scilit:
- Fractional Brownian motion in crowded fluidsSoft Matter, 2012
- Fractional Brownian Motion Versus the Continuous-Time Random Walk: A Simple Test for Subdiffusive DynamicsPhysical Review Letters, 2009
- Eddy‐current compensated diffusion weighting with a single refocusing RF pulseMagnetic Resonance in Medicine, 2009
- Integrated SENSE DTI with correction of susceptibility- and eddy current-induced geometric distortionsNeuroImage, 2008
- Physical Nature of Bacterial CytoplasmPhysical Review Letters, 2006
- New modeling and experimental framework to characterize hindered and restricted water diffusion in brain white matterMagnetic Resonance in Medicine, 2004
- High b‐value q‐space analyzed diffusion‐weighted MRS and MRI in neuronal tissues – a technical reviewNMR in Biomedicine, 2002
- Correction of concomitant magnetic field‐induced image artifacts in nonaxial echo‐planar imagingMagnetic Resonance in Medicine, 2002
- Diffusion imaging using stimulated echoesMagnetic Resonance in Medicine, 1991
- The Choice of Variables in Observational StudiesJournal of the Royal Statistical Society Series C: Applied Statistics, 1974