Performance of a Venturi scrubber in the removal of fine powder from a confined gas stream
Open Access
- 1 June 2005
- journal article
- Published by FapUNIFESP (SciELO) in Materials Research
- Vol. 8 (2) , 177-179
Abstract
Experimental results on the performance of a laboratory scale rectangular Venturi scrubber in the removal of fine mineral particles from a confined air stream are presented, and a new correlation is proposed and evaluated. The scrubber was operated with air velocities in the throat varying from 58 m/s to 75 m/s and liquid flow rates varying from 280 ml/min to 900 ml/min. Liquid was injected as a jet emerging from a 1.0 mm orifice at the throat. Results for dust collection grade efficiency varied from 87% to 98% for particles from 0.1 µm to 2.0 µmKeywords
This publication has 3 references indexed in Scilit:
- Modeling of Venturi Scrubber PerformanceIndustrial & Engineering Chemistry Research, 1997
- Mathematical modeling of atomizing scrubbersAIChE Journal, 1975
- Mean Drop Size in a Full Scale Venturi Scrubber via TransmissometerJournal of the Air Pollution Control Association, 1974