JCJosé Renato Coury

José Renato Coury

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


José Renato Coury has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Measurement of the electrostatic charge in airborne particles: II - particle charge distribution of different aerosols

    by M. V. Rodrigues, W. D. Marra Jr., R. G. Almeida, J. R. Coury

    This work gives sequence to the study on the measurement of the electrostatic charges in aerosols. The particle charge classifier developed for this purpose and presented in the previous paper (Marra and Coury, 2000) has been used here to measure the particle charge distribution of a number of different aerosols. The charges acquired by the particles were naturally derived from the aerosol generation procedure itself. Two types of aerosol generators were used: the vibrating orifice generator and turntable Venturi plate generator. In the vibrating orifice generator, mono-dispersed particles were generated by a solution of water/ethanol/methylene blue, while in the rotating plate generator, six different materials were utilized. The results showed no clear dependence between electric charge and particle diameter for the mono-dispersed aerosol. However, for the poly-dispersed aerosols, a linear dependence between particle size and charge could be noticed


  • Open Access

    Performance of a Venturi scrubber in the removal of fine powder from a confined gas stream

    by Maria Angélica Martins Costa, Ana Paula Rodrigues Alves Ribeiro, Érica Rodrigues Tognetti, Mônica Lopes Aguiar, José Antônio Silveira Gonçalves, José Renato Coury

    Experimental results on the performance of a laboratory scale rectangular Venturi scrubber in the removal of fine mineral particles from a confined air stream are presented, and a new correlation is proposed and evaluated. The scrubber was operated with air velocities in the throat varying from 58 m/s to 75 m/s and liquid flow rates varying from 280 ml/min to 900 ml/min. Liquid was injected as a jet emerging from a 1.0 mm orifice at the throat. Results for dust collection grade efficiency varied from 87% to 98% for particles from 0.1 µm to 2.0 µm


  • Open Access

    Filtração de aerossóis em altas temperaturas utilizando filtros cerâmicos de dupla camada: influência do diâmetro de partícula na eficiência de coleta

    by N. L de Freitas, M. G. Maniero, J. R. Coury

    Neste trabalho foram utilizados filtros cerâmicos para filtração de aerossóis, constituídos por dupla camada, onde a primeira camada é formada por um suporte celular de elevada porosidade com diâmetro de poro controlado e a segunda formada por uma película filtrante. A camada suporte foi obtida pela técnica de replicação cerâmica de espuma poliuretânica, por meio da impregnação de uma suspensão aquosa de Al2O3. Foram utilizados suportes de 45 e 75 poros/polegada. A membrana filtrante (Al2O3 e argila) foi a mesma para ambos os suportes, sendo composta por uma massa granular cerâmica de baixa porosidade. Os experimentos de filtração foram realizados em temperaturas de 25 a 700 ºC onde mediu-se a capacidade dos filtros de limpar um aerossol de partículas finas polidispersas (diâmetro mediano de 4,6 µm) e calculou-se a eficiência de coleta para diâmetros de partícula entre 0,4 e 8,5 µm. Os resultados mostraram que a eficiência diminuiu com o aumento da temperatura e aumentou com o diâmetro da partícula.


  • Open Access

    Espectro de gotas de bicos de pulverização hidráulicos de jato plano e de jato cônico vazio

    by João Paulo Arantes Rodrigues da Cunha, Mauri Martins Teixeira, Rogério Faria Vieira, Haroldo Carlos Fernandes, José Renato Coury

    A escolha e o uso adequado de bicos de pulverização são essenciais para a correta aplicação de agrotóxicos. Este trabalho teve como objetivo avaliar o espectro de gotas de bicos de pulverização hidráulicos de jato plano padrão e de jato cônico vazio, com diferentes vazões nominais. Em ambiente controlado, avaliou-se o espectro de gotas por meio de um analisador a laser de gotas em tempo real, nas faixas de pressão de 200 a 400 kPa para os bicos de jato plano, e de 400 a 600 kPa para os bicos de jato cônico vazio. Realizou-se também um estudo teórico sobre a distância horizontal percorrida por gotas de tamanho conhecido. Os bicos de jato cônico vazio apresentaram gotas de menor tamanho em relação aos de jato plano e, por isso, proporcionaram maior densidade de gotas depositadas sobre a superfície-alvo. Todos os bicos apresentaram densidade de gotas superior a 110 gotas cm-2. No entanto, o potencial de deriva foi alto, principalmente o dos bicos de jato cônico, requerendo estratégias para sua redução. É possível estimar a distância horizontal percorrida por gotas de tamanho conhecido.


  • Open Access

    A study of a wire-plate eletrostatic precipitator operating in the removal of polydispersed particles

    by S. W. Nóbrega, M. C. R. Falaguasta, J. R. Coury

    Performance of a wire-plate electrostatic precipitator in the removal of particles with a wide particle size distribution was evaluated. The experimental rig utilized consisted of a set of three precipitators whose dimensions could be varied. It was observed that precipitator performance increased with an increase in the gap between the collecting plates, which resulted in a substantial increase in energy consumption per volume of cleaned gas. The grade efficiency predicted by correlations from the literature did not match the experimental measurements, and a new correlation is proposed


  • Open Access

    Droplet size in a rectangular Venturi scrubber

    by M. A. M. Costa, P. R. Henrique, J. A. S. Gonçalves, J.R. Coury

    The Venturi scrubber is a device which uses liquid in the form of droplets to efficiently remove fine particulate matter from gaseous streams. Droplet size is of fundamental importance for the scrubber performance. In the present experimental study, a laser diffraction technique was used in order to measure droplet size in situ in a Venturi scrubber with a rectangular cross section. Droplet size distribution was measured as a function of gas velocity (58.3 to 74.9 m/s), liquid-to-gas ratio (0.07 to 0.27 l/m³), and distance from liquid injection point (64 to 173 mm). It was found that all these variables significantly affect droplet size. The results were compared with the predictions from correlations found in the literature.


  • Open Access

    The influence of structural parameters on the permeability of ceramic foams

    by E. A. Moreira, J. R. Coury

    Ceramic foams are a new structural material, characterized by a high porosity and a large surface area and made of megapores interconnected by filaments. This results in a structure with low resistance to fluid flow, making them appropriate for use as a filter. This work studies the influence of several structural parameters, such as porosity, tortuosity, surface area and pore diameter, in predicting the permeability of ceramic foams. Foams with different pore densities were used as porous media. Permeability was measured utilizing water as the flowing fluid. The results show that the predicted permeability scatters widely with the parameters under study. Pore diameter was the structural parameter that best represented the media. An Ergun-type correlation was fitted to the data and represented very well the permeability of the media in all foams under the experimental conditions studied.


  • Open Access

    Performance of cylindrical-conical cyclones with different geometrical configurations

    by J.D.A.M. Santana, S. Arnosti Jr., J.R. Coury

    The present work is a continuation of a study of the influence of geometric characteristics on the performance of reverse-flow cylindrical-conical cyclones. After studying the behavior of the pressure drop in previous work (Arnosti et al., 1998), here performance in terms of collection efficiency in the removal of particulate material is addressed. The independent variables considered in this study were inlet gas velocity (three velocities) and the following dimensions of the cyclone: the cylindrical section (three heights) and internal height of the gas exit duct (three heights). The tests were performed using an 3³ experimental design. Analysis of the results for overall efficiency was carried out using response surfaces and the statistical parameters were estimated from linear regression


  • Open Access

    Evaluation of the performance of a wire-plate electrostatic precipitator

    by S.W. Nóbrega, S. Arnosti Jr, J.R. Coury

    This work presents an analysis based on experimental measurement of the influence of gas velocity, applied potential, diameter of the active electrode and distance between two consecutive active electrodes in the performance of a wire-plate electrostatic precipitator. The dimensions of the experimental equipment were as follows: length = 0.5 m, height = 0.3 m, width = 0.3 m, number of ducts = 3, distance between the collection electrodes = 0.1 m and collection area = 0.9 m². The particulate material used in the tests was a phosphatic concentrate with a density of 3.0 x 10³ kg/m³ and a mean particle size of 8.0 mum. The performance of the precipitator was evaluated by measuring its overall collection efficiency, obtained by isokinetic sampling at the entrance and exit of the experimental system. The results were compared to predictions obtained using the classic Deutsch-Anderson equation as well as the one from Zhao et al. (1996). A correction factor is proposed.