Abstract
We present a modular Zeeman slower based on permanent magnets, designed for miniaturized quantum sensor applications like Sr optical lattice clocks. Using a longitudinal magnetic field geometry, the 3D printed system replicates the field profile of traditional solenoid-based Zeeman slowers without power consumption or active cooling. The Zeeman slower achieves comparable performance to solenoidbased designs, with a similar number of Sr atoms loaded into the magneto-optical trap at 461 nm transition. This approach offers a low-cost, low-power solution for portable quantum technologies.
Funding Information
  • Narodowe Centrum Badań i Rozwoju (QUANTERAII/1/921QuantumGuide/2022)
  • European Commission (101080166)
  • QuantERA grant QuantumGuide

This publication has 29 references indexed in Scilit: