Michal Zawada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Michal Zawada has a total of 416 co-authors. Here are the top co-authors by number of shared publications:
- Roman Ciurylo
Nicolaus Copernicus University in Torun
29 shared publications - Marcin Bober
Nicolaus Copernicus University
24 shared publications - Piotr Morzyński
Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Grudziadzka 5, PL-87-100 Toruń, Poland
23 shared publications - Marcin Witkowski
Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Grudziadzka 5, PL-87-100 Toruń, Poland
18 shared publications - Agata Cygan
Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University in Torun, Grudziadzka 5, 87-100 Torun, Poland
14 shared publications - Daniel Lisak
Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University in Torun, Grudziadzka 5, 87-100 Torun, Poland
14 shared publications
Latest Publications
- Open Access
- 15 November 2026
- Published by Elsevier in Measurement
- Vol. 295
Long distance optical frequency transfer with short-term phase noise suppressed by a clean-up-supported remote terminal
- 15 November 2026
- Published by Elsevier in Measurement
- Vol. 295
Open AccessLong distance optical frequency transfer with short-term phase noise suppressed by a clean-up-supported remote terminal
- Open Access
- 3 June 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (28) , 285003
A Zeeman slower based on permanent magnets for optical atomic clocks
We present a modular Zeeman slower based on permanent magnets, designed for miniaturized quantum sensor applications like Sr optical lattice clocks. Using a longitudinal magnetic field geometry, the 3D printed system replicates the field profile of traditional solenoid-based Zeeman slowers without power consumption or active cooling. The Zeeman slower achieves comparable performance to solenoidbased designs, with a similar number of Sr atoms loaded into the magneto-optical trap at 461 nm transition. This approach offers a low-cost, low-power solution for portable quantum technologies.
- 3 June 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (28) , 285003
Open AccessA Zeeman slower based on permanent magnets for optical atomic clocks
We present a modular Zeeman slower based on permanent magnets, designed for miniaturized quantum sensor applications like Sr optical lattice clocks. Using a longitudinal magnetic field geometry, the 3D printed system replicates the field profile of traditional solenoid-based Zeeman slowers without power consumption or active cooling. The Zeeman slower achieves comparable performance to solenoidbased designs, with a similar number of Sr atoms loaded into the magneto-optical trap at 461 nm transition. This approach offers a low-cost, low-power solution for portable quantum technologies.
- Open Access
- 22 May 2026
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 8 (2)
Spectrometry of captured highly charged ions produced following antiproton annihilations
We report the first capture and time-of-flight spectrometry of highly charged ions (HCIs) produced following annihilations of trapped antiprotons in a Penning-Malmberg trap. A multistep nested-trap technique was developed at the AEḡIS experiment at CERN to trap and identify the annihilation-linked ions using external scintillators. The successful capture and mass analysis of helium and argon ions confirm the viability of the approach. This proof-of-principle demonstration establishes the foundation for future high-resolution mass spectrometry of recoil-filtered nuclear annihilation fragments. This methodology could enable studies of antiprotonic atom formation and cascade dynamics, allow the in-trap synthesis of radioactive HCIs, and provide a particularly sensitive probe of the neutron-to-proton composition at the outer periphery of the nucleus.
- 22 May 2026
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 8 (2)
Open AccessSpectrometry of captured highly charged ions produced following antiproton annihilations
We report the first capture and time-of-flight spectrometry of highly charged ions (HCIs) produced following annihilations of trapped antiprotons in a Penning-Malmberg trap. A multistep nested-trap technique was developed at the AEḡIS experiment at CERN to trap and identify the annihilation-linked ions using external scintillators. The successful capture and mass analysis of helium and argon ions confirm the viability of the approach. This proof-of-principle demonstration establishes the foundation for future high-resolution mass spectrometry of recoil-filtered nuclear annihilation fragments. This methodology could enable studies of antiprotonic atom formation and cascade dynamics, allow the in-trap synthesis of radioactive HCIs, and provide a particularly sensitive probe of the neutron-to-proton composition at the outer periphery of the nucleus.
- Open Access
- 31 March 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 245
Production of negatively charged atomic ions inside a linear Paul trap for the formation of antiprotonic atoms
- 31 March 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 245
Open AccessProduction of negatively charged atomic ions inside a linear Paul trap for the formation of antiprotonic atoms
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 6, 307-313
Coherent Linking of 698- and 1542-nm Lasers via an Optical Frequency Comb With Automated Control
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 6, 307-313
Open AccessCoherent Linking of 698- and 1542-nm Lasers via an Optical Frequency Comb With Automated Control
- 14 November 2025
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 42 (12) , 2753
Modeling a convex–concave ultra-stable optical cavity
The current performance of the state-of-the-art Fabry–Pérot optical resonators is limited by thermal processes through an energy dissipation mechanism. The dominant source of noise in both long-range interferometers and table-top ultra-stable cavities is the µm thick layer of highly reflective Bragg mirrors. Depending on the material used in mirror substrates, reflective coatings, and cavity temperature, the dominant noises that limit the stability of the cavity include Brownian, thermoelastic, and thermo-optic noises. We propose enhancing the beam spot size on the mirror surface to overcome current thermal limitations by applying the convex–concave configuration. We present the theoretical investigations of the convex–concave mirrors design for ultra-stable cavity purposes and prove that this configuration can significantly reduce Brownian coating noise. We prove the feasibility of the proposed design by verifying its stability conditions.
- 14 November 2025
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 42 (12) , 2753
Modeling a convex–concave ultra-stable optical cavity
The current performance of the state-of-the-art Fabry–Pérot optical resonators is limited by thermal processes through an energy dissipation mechanism. The dominant source of noise in both long-range interferometers and table-top ultra-stable cavities is the µm thick layer of highly reflective Bragg mirrors. Depending on the material used in mirror substrates, reflective coatings, and cavity temperature, the dominant noises that limit the stability of the cavity include Brownian, thermoelastic, and thermo-optic noises. We propose enhancing the beam spot size on the mirror surface to overcome current thermal limitations by applying the convex–concave configuration. We present the theoretical investigations of the convex–concave mirrors design for ultra-stable cavity purposes and prove that this configuration can significantly reduce Brownian coating noise. We prove the feasibility of the proposed design by verifying its stability conditions.
- 14 October 2025
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 42 (11) , 2488
Mechanical loss and stability analysis of NEXCERA in ultra-stable optical cavities
NEXCERA has emerged as a ceramic-based material for spacers in ultra-stable optical cavities, with a coefficient of thermal expansion that crosses zero near room temperature. In such cavities, frequency stability is ultimately limited by Brownian thermal noise in the cavity components. A key parameter in this context is the mechanical loss, which has remained unknown for NEXCERA. In this work, we investigate the mechanical loss of NEXCERA N117B at room temperature for various resonances using the gentle nodal suspension technique. We measure a promising minimum mechanical loss of ϕ =1.89×10 −5 , indicating the suitability of NEXCERA for low-noise optical cavities. Using this value, we calculate the thermal noise of a cavity with a NEXCERA spacer and compare its performance to established materials such as ULE and Zerodur, taking into account different mirror substrate options. Our analysis shows that NEXCERA is a strong candidate for ultra-stable cavities due to its low thermal noise. Combined with its previously reported low linear drift, it offers a highly attractive option for long-term stable optical frequency references.
- 14 October 2025
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 42 (11) , 2488
Mechanical loss and stability analysis of NEXCERA in ultra-stable optical cavities
NEXCERA has emerged as a ceramic-based material for spacers in ultra-stable optical cavities, with a coefficient of thermal expansion that crosses zero near room temperature. In such cavities, frequency stability is ultimately limited by Brownian thermal noise in the cavity components. A key parameter in this context is the mechanical loss, which has remained unknown for NEXCERA. In this work, we investigate the mechanical loss of NEXCERA N117B at room temperature for various resonances using the gentle nodal suspension technique. We measure a promising minimum mechanical loss of ϕ =1.89×10 −5 , indicating the suitability of NEXCERA for low-noise optical cavities. Using this value, we calculate the thermal noise of a cavity with a NEXCERA spacer and compare its performance to established materials such as ULE and Zerodur, taking into account different mirror substrate options. Our analysis shows that NEXCERA is a strong candidate for ultra-stable cavities due to its low thermal noise. Combined with its previously reported low linear drift, it offers a highly attractive option for long-term stable optical frequency references.
- Open Access
- 4 April 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (14) , eads1176
Real-time antiproton annihilation vertexing with submicrometer resolution
Primary goal of the AEḡIS experiment is to precisely measure the free fall of antihydrogen within Earth’s gravitational field. To this end, cold (≈50 K) antihydrogen will traverse a two-grid moiré deflectometer before annihilating onto a position-sensitive detector, which shall determine the vertical position of the annihilation vertex relative to the grids with micrometric accuracy. Here, we introduce a vertexing detector based on a modified mobile camera sensor and experimentally demonstrate that it can measure the position of antiproton annihilations within 0.62 − 0.22 + 0.40 μm, a 35-fold improvement over the previous state of the art for real-time antiproton vertexing. These methods are directly applicable to antihydrogen. Moreover, the sensitivity to light of the sensor enables in situ calibration of the moiré deflectometer, substantially reducing systematic errors. This sensor emerges as a breakthrough technology toward the AEḡIS scientific goals and will constitute the basis for the development of a large-area detector for conducting antihydrogen gravity measurements.
- 4 April 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (14) , eads1176
Open AccessReal-time antiproton annihilation vertexing with submicrometer resolution
Primary goal of the AEḡIS experiment is to precisely measure the free fall of antihydrogen within Earth’s gravitational field. To this end, cold (≈50 K) antihydrogen will traverse a two-grid moiré deflectometer before annihilating onto a position-sensitive detector, which shall determine the vertical position of the annihilation vertex relative to the grids with micrometric accuracy. Here, we introduce a vertexing detector based on a modified mobile camera sensor and experimentally demonstrate that it can measure the position of antiproton annihilations within 0.62 − 0.22 + 0.40 μm, a 35-fold improvement over the previous state of the art for real-time antiproton vertexing. These methods are directly applicable to antihydrogen. Moreover, the sensitivity to light of the sensor enables in situ calibration of the moiré deflectometer, substantially reducing systematic errors. This sensor emerges as a breakthrough technology toward the AEḡIS scientific goals and will constitute the basis for the development of a large-area detector for conducting antihydrogen gravity measurements.
- Open Access
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
TALOS (Total Automation of LabVIEW Operations for Science): A framework for autonomous control systems for complex experiments
Modern physics experiments are frequently very complex, relying on multiple simultaneous events to happen in order to obtain the desired result. The experiment control system plays a central role in orchestrating the measurement setup: However, its development is often treated as secondary with respect to the hardware, its importance becoming evident only during the operational phase. Therefore, the AEḡIS (Antimatter Experiment: Gravity, Interferometry, Spectroscopy) collaboration has created a framework for easily coding control systems, specifically targeting atomic, quantum, and antimatter experiments. This framework, called Total Automation of LabVIEW Operations for Science (TALOS), unifies all the machines of the experiment in a single entity, thus enabling complex high-level decisions to be taken, and it is constituted by separate modules, called MicroServices, that run concurrently and asynchronously. This enhances the stability and reproducibility of the system while allowing for continuous integration and testing while the control system is running. The system demonstrated high stability and reproducibility, running completely unsupervised during the night and weekends of the data-taking campaigns. The results demonstrate the suitability of TALOS to manage an entire physics experiment in full autonomy: being open-source, experiments other than the AEḡIS experiment can benefit from it.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Open AccessTALOS (Total Automation of LabVIEW Operations for Science): A framework for autonomous control systems for complex experiments
Modern physics experiments are frequently very complex, relying on multiple simultaneous events to happen in order to obtain the desired result. The experiment control system plays a central role in orchestrating the measurement setup: However, its development is often treated as secondary with respect to the hardware, its importance becoming evident only during the operational phase. Therefore, the AEḡIS (Antimatter Experiment: Gravity, Interferometry, Spectroscopy) collaboration has created a framework for easily coding control systems, specifically targeting atomic, quantum, and antimatter experiments. This framework, called Total Automation of LabVIEW Operations for Science (TALOS), unifies all the machines of the experiment in a single entity, thus enabling complex high-level decisions to be taken, and it is constituted by separate modules, called MicroServices, that run concurrently and asynchronously. This enhances the stability and reproducibility of the system while allowing for continuous integration and testing while the control system is running. The system demonstrated high stability and reproducibility, running completely unsupervised during the night and weekends of the data-taking campaigns. The results demonstrate the suitability of TALOS to manage an entire physics experiment in full autonomy: being open-source, experiments other than the AEḡIS experiment can benefit from it.
- Open Access
- 1 August 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (4) , 045009
Intercontinental frequency ratio measurement of 171 Yb and 88 Sr optical lattice clocks
We report a remote, intercontinental frequency comparison between 171Yb (NMIJ) and 88Sr (UMK) optical lattice clocks. The frequencies were compared via the Global Positioning System Precise Point Positioning technique over the period from 10 March 2020, 00:00 UTC until 15 March 2020, 00:00 UTC. The comparison of the optical clocks yields results with a relative frequency uncertainty of 6.3 × 10 − 15 .
- 1 August 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (4) , 045009
Open AccessIntercontinental frequency ratio measurement of 171 Yb and 88 Sr optical lattice clocks
We report a remote, intercontinental frequency comparison between 171Yb (NMIJ) and 88Sr (UMK) optical lattice clocks. The frequencies were compared via the Global Positioning System Precise Point Positioning technique over the period from 10 March 2020, 00:00 UTC until 15 March 2020, 00:00 UTC. The comparison of the optical clocks yields results with a relative frequency uncertainty of 6.3 × 10 − 15 .