Utility of Transesophageal Echocardiography for Transcatheter Occlusion of Patent Ductus Arteriosus in Dogs: Influence on the Decision-Making Process
Open Access
- 24 August 2010
- journal article
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 24 (6) , 1407-1413
Abstract
Background: Appropriate device selection for transcatheter occlusion of patent ductus arteriosus (PDA) is essential to procedural success. Objectives: To determine if transesophageal echocardiography (TEE) influences device selection for PDA occlusion and to report benefits, limitations, and complications associated with TEE. Animals: Twenty-two client-owned dogs with left-to-right shunting PDA. Methods: PDA dimensions were obtained via transthoracic echocardiography (TTE) and then TEE followed by angiography. Based solely on information from TTE and angiography, an initial device type and size were selected. After initial device selection, TEE measurements were disclosed and changes in device selection were recorded. After device release, angiography, TEE, or both were performed to assess occlusion. Results: An Amplatz canine duct occluder (ACDO) was securely positioned and released in 21 dogs and an embolization coil was deployed in 1 dog. Based on TEE evaluation, initial selected device type was unchanged but ACDO size was changed in 3 dogs. TEE was utilized throughout the procedure allowing real time visualization of device deployment, release and assessment of closure in 17 dogs. No complications occurred related to TEE. Complete PDA closure was achieved in all dogs. Conclusions and Clinical Importance: TEE provided anatomic information regarding PDA morphology that closely approximated angiographic ductal dimensions while aiding in device deployment, release and confirmation of closure. We conclude that TEE provides complementary anatomical and intraprocedural information and is well tolerated in dogs.Keywords
This publication has 14 references indexed in Scilit:
- Transarterial ductal occlusion using the Amplatz® Canine Duct Occluder in 40 dogsJournal of Veterinary Cardiology, 2010
- Transarterial Ductal Occlusion with the Amplatzer Vascular Plug in 31 DogsJournal of Veterinary Internal Medicine, 2008
- Minimally Invasive Per-Catheter Patent Ductus Arteriosus Occlusion in Dogs Using a Prototype Duct OccluderJournal of Veterinary Internal Medicine, 2008
- Transthoracic Echocardiographic Measurement of Patent Ductus Arteriosus in DogsJournal of Veterinary Internal Medicine, 2007
- Echocardiographic and Angiographic Comparison of Ductal Dimensions in Dogs with Patent Ductus ArteriosusJournal of Veterinary Internal Medicine, 2007
- Angiographic classification of patent ductus arteriosus morphology in the dogJournal of Veterinary Cardiology, 2006
- Catheter closure of patent ductus arteriosus in dogs: variation in ductal size requires different techniquesJournal of Veterinary Cardiology, 2003
- Etiology of Patent Ductus Arteriosus in DogsJournal of Veterinary Internal Medicine, 2003
- The Use of Transesophageal Echocardiography Monitoring of Transcatheter Closure of a Persistent Ductus ArteriosusEchocardiography, 2001
- Transcatheter Closure of Patent Ductus Arteriosus Using Occluding Spring CoilsJournal of Veterinary Internal Medicine, 2000