Comparison of the use of AnaConDa® versus AnaConDa-S® during the post-operative period of cardiac surgery under standard conditions of practice
- 19 February 2019
- journal article
- research article
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 34 (1) , 89-95
Abstract
Changes have been made to the AnaConDa device (Sedana Medical, Stockholm, Sweden), decreasing its size to reduce dead space and carbon dioxide (CO2) retention. However, this also involves a decrease in the surface area of the activated carbon filter. The CO2 elimination and sevoflurane (SEV) reflection of the old device (ACD-100) were thus compared with the new version (ACD-50) in patients sedated after coronary artery bypass graft surgery. After ERC approval and written informed consent, 23 patients were sedated with SEV, using first the ACD-100 and then the ACD-50 for 60 min each. With each device, patients were ventilated with tidal volumes (TV) of 5 ml/kg of ideal body weight for the first 30 min, and with 7 ml/kg for the next 30 min. Ventilation parameters, arterial blood gases, Bispectral-Index™ (BIS, Aspect Medical Systems Inc., Newton, MA, USA), SEV concentrations exhaled by the patient (SEV-exhaled) and from the expiratory hose (SEV-lost) were recorded every 30 min. A SEV reflection index was calculated: SRI [%] = 100 × (1 − (SEV-lost/SEV-exhaled)). Data were compared using ANOVA with repeated measurements and Student’s T-tests for pairs. Respiratory rates, tidal and minute volumes were not significantly different between the two devices. End tidal and arterial CO2 partial pressures were significantly higher with the ACD-100 as compared with the ACD-50. SEV infusion rate remained constant. SEV reflection was higher (SRI: ACD-100 vs. ACD-50, TV 5 ml/kg: 95.29 ± 6.45 vs. 85.54 ± 11.15, p = 0.001; 7 ml/kg: 93.42 ± 6.55 vs. 88.77 ± 12.26, p = 0.003). BIS was significantly lower when using the higher TV (60.91 ± 9.99 vs. 66.57 ± 8.22, p = 0.012), although this difference was not clinically relevant. During postoperative sedation, the use of ACD-50 significantly reduced CO2 retention. SEV reflection was slightly reduced. However, patients remained sufficiently sedated without increasing SEV infusion.Keywords
This publication has 20 references indexed in Scilit:
- Halving the Volume of AnaConDa: Evaluation of a New Small-Volume Anesthetic Reflector in a Test Lung ModelAnesthesia & Analgesia, 2019
- Volumetric and reflective device dead space of anaesthetic reflectors under different conditionsJournal of Clinical Monitoring and Computing, 2018
- Efficient application of volatile anaesthetics: total rebreathing or specific reflection?Journal of Clinical Monitoring and Computing, 2018
- Sedation After Cardiac Surgery: Is One Drug Better Than Another?Anesthesia & Analgesia, 2017
- Evaluating the efficiency of desflurane reflection in two commercially available reflectorsJournal of Clinical Monitoring and Computing, 2016
- Effects of Volatile Anesthetics on Mortality and Postoperative Pulmonary and Other Complications in Patients Undergoing SurgeryAnesthesiology, 2016
- A novel device for target controlled administration and reflection of desflurane – the Mirus ™Anaesthesia, 2014
- Apparent Dead Space with the Anesthetic Conserving Device, AnaConDa®Anesthesia & Analgesia, 2013
- Carbon dioxide rebreathing with the anaesthetic conserving device, AnaConDa ®British Journal of Anaesthesia, 2012
- The Predictive Performance of a Pharmacokinetic Model for Manually Adjusted Infusion of Liquid Sevofluorane for Use with the Anesthetic-Conserving Device (AnaConDa): A Clinical StudyAnesthesia & Analgesia, 2008