Abstract
Objective — To evaluate the effect of the frequency of retinoprotective therapy courses on perimetry parameters, to compare Octopus 900 perimeter with Octopus 600 perimeter, and to assess threshold perimetry results of G-dynamic versus 24-2 programs. Material and Methods — The study involved 17 patients (34 eyes) diagnosed with primary open-angle glaucoma of advanced stage. Group 1 included subjects receiving a course of Retinalamin every 3 months. Group 2 comprised patients undergoing Retinalamin therapeutics every 6 months. Results — At the onset of the study via G-dynamic and 24-2 programs, we did not observe any statistically significant differences between the groups in mean deviation of retinal photosensitivity (MD) and pattern standard deviation of mean retinal photosensitivity (PSD). However, the absolute values differed between groups and between programs. On average, the differences in MD and PSD values obtained in the photosensitivity study with G-dynamic vs. 24-2 programs were -0.36 dB (CI 95%: -4.27; 3.54) and 0.63 dB (CI 95%: 2.37; -1.11), respectively. Hence, studies performed via 24-2 and G-dynamic programs yielded comparable results (no statistically significant differences). However, they could not be identical due to different spatial arrangement of points in different programs. Conclusion — As a result of conducted treatment, retinal photosensitivity did not exhibit statistically significant changes; however, we observed positive dynamics in both groups in MD and PSD parameters of mean retinal photosensitivity. Different devices (Octopus 600 and Octopus 900 perimeters) and different programs (24-2, G-dynamic) yielded different outcomes due to their technical features and capabilities of reproducibility; however, these differences were not statistically significant.Keywords
This publication has 16 references indexed in Scilit:
- The influence of long-term retinal protective therapy on glaucoma progression according to structural and functional testsRussian Annals of Ophthalmology, 2020
- [Effectiveness of antihypertensive conservative-free therapy with fixed combination of bimatoprost and timolol (intermediate results)].Russian Annals of Ophthalmology, 2020
- Spatial contrast sensitivity in patients with primary open-angle glaucoma and ocular hypertensionRussian Annals of Ophthalmology, 2020
- A New SITA Perimetric Threshold Testing Algorithm: Construction and a Multicenter Clinical StudyAmerican Journal of Ophthalmology, 2019
- [The effect of preservative-free treatment of primary open-angle glaucoma on the state of ocular surface in combination therapy (intermediate results)].Russian Annals of Ophthalmology, 2019
- Global Prevalence of Glaucoma and Projections of Glaucoma Burden through 2040Ophthalmology, 2014
- Definition of glaucoma: clinical and experimental conceptsClinical & Experimental Ophthalmology, 2012
- SITA Fast, a new rapid perimetric threshold test. Description of methods and evaluation in patients with manifest and suspect glaucomaActa Ophthalmologica Scandinavica, 1998
- Evaluation of a new perimetric threshold strategy, SITA, in patients with manifest and suspect glaucomaActa Ophthalmologica Scandinavica, 1998
- Optical coherence tomography: A new tool for glaucoma diagnosisCurrent Opinion in Ophthalmology, 1995