Ilya V. Kokorin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ilya V. Kokorin has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Anastasiya S. Chemyakina
S.N. Fyodorov National Medical Research Center for Eye Microsurgery, Moscow, Russia
1 shared publication - Artem Z. Tsyganov
S.N. Fyodorov National Medical Research Center for Eye Microsurgery, Moscow, Russia
1 shared publication - Dmitry A. Dorofeev
Krasnov Research Institute of Eye Diseases
1 shared publication - Elena V. Kirilik
Chelyabinsk Public Clinical Hospital No. 2, Chelyabinsk, Russia
1 shared publication - Olga B. Solovieva
GEROPHARM LLC, Moscow, Russia
1 shared publication - Polina A. Rakova
South Ural State Medical University, Chelyabinsk, Russia
1 shared publication
Latest Publications
- 20 March 2022
- Published by LLC Science and Innovations in Russian Open Medical Journal
- Vol. 11 (1)
Perimetry Criteria For Assessing The Effectiveness Of Retinoprotective Therapy
Objective — To evaluate the effect of the frequency of retinoprotective therapy courses on perimetry parameters, to compare Octopus 900 perimeter with Octopus 600 perimeter, and to assess threshold perimetry results of G-dynamic versus 24-2 programs. Material and Methods — The study involved 17 patients (34 eyes) diagnosed with primary open-angle glaucoma of advanced stage. Group 1 included subjects receiving a course of Retinalamin every 3 months. Group 2 comprised patients undergoing Retinalamin therapeutics every 6 months. Results — At the onset of the study via G-dynamic and 24-2 programs, we did not observe any statistically significant differences between the groups in mean deviation of retinal photosensitivity (MD) and pattern standard deviation of mean retinal photosensitivity (PSD). However, the absolute values differed between groups and between programs. On average, the differences in MD and PSD values obtained in the photosensitivity study with G-dynamic vs. 24-2 programs were -0.36 dB (CI 95%: -4.27; 3.54) and 0.63 dB (CI 95%: 2.37; -1.11), respectively. Hence, studies performed via 24-2 and G-dynamic programs yielded comparable results (no statistically significant differences). However, they could not be identical due to different spatial arrangement of points in different programs. Conclusion — As a result of conducted treatment, retinal photosensitivity did not exhibit statistically significant changes; however, we observed positive dynamics in both groups in MD and PSD parameters of mean retinal photosensitivity. Different devices (Octopus 600 and Octopus 900 perimeters) and different programs (24-2, G-dynamic) yielded different outcomes due to their technical features and capabilities of reproducibility; however, these differences were not statistically significant.
- 20 March 2022
- Published by LLC Science and Innovations in Russian Open Medical Journal
- Vol. 11 (1)
Perimetry Criteria For Assessing The Effectiveness Of Retinoprotective Therapy
Objective — To evaluate the effect of the frequency of retinoprotective therapy courses on perimetry parameters, to compare Octopus 900 perimeter with Octopus 600 perimeter, and to assess threshold perimetry results of G-dynamic versus 24-2 programs. Material and Methods — The study involved 17 patients (34 eyes) diagnosed with primary open-angle glaucoma of advanced stage. Group 1 included subjects receiving a course of Retinalamin every 3 months. Group 2 comprised patients undergoing Retinalamin therapeutics every 6 months. Results — At the onset of the study via G-dynamic and 24-2 programs, we did not observe any statistically significant differences between the groups in mean deviation of retinal photosensitivity (MD) and pattern standard deviation of mean retinal photosensitivity (PSD). However, the absolute values differed between groups and between programs. On average, the differences in MD and PSD values obtained in the photosensitivity study with G-dynamic vs. 24-2 programs were -0.36 dB (CI 95%: -4.27; 3.54) and 0.63 dB (CI 95%: 2.37; -1.11), respectively. Hence, studies performed via 24-2 and G-dynamic programs yielded comparable results (no statistically significant differences). However, they could not be identical due to different spatial arrangement of points in different programs. Conclusion — As a result of conducted treatment, retinal photosensitivity did not exhibit statistically significant changes; however, we observed positive dynamics in both groups in MD and PSD parameters of mean retinal photosensitivity. Different devices (Octopus 600 and Octopus 900 perimeters) and different programs (24-2, G-dynamic) yielded different outcomes due to their technical features and capabilities of reproducibility; however, these differences were not statistically significant.