Structural properties in ruptured mitral chordae tendineae measured by synchrotron-based X-ray phase computed tomography
Open Access
- 18 August 2023
- journal article
- research article
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 30 (5) , 995-1002
Abstract
The link between the structural properties and the rupturing of chordae tendineae in the mitral valve complex is still unclear. Synchrotron-radiation-based X-ray phase computed tomography (SR-XPCT) imaging is an innovative way to quantitatively analyze three-dimensional morphology. XPCT has been employed in this study to evaluate the chordae tendineae from patients with mitral regurgitation and to analyze structural changes in the ruptured chordae tendineae in patients with this condition. Six ruptured mitral chordae tendineae were obtained during surgical repairs for mitral regurgitation and were fixed with formalin. In addition, 12 healthy chordae tendineae were obtained from autopsies. Employing XPCT (effective pixel size, 3.5 µm; density resolution, 1 mg cm−3), the density of the chordae tendineae in each sample was measured. The specimens were subsequently analyzed pathologically. The mean age was 70.2 ± 3.0 in the rupture group and 67.2 ± 14.1 years old in the control group (p = 0.4927). All scans of chorda tendineae with SR-XPCT were performed successfully. The mean densities were 1.029 ± 0.004 in the rupture group and 1.085 ± 0.015 g cm−3 in the control group (p < 0.0001). Density based on SR-XPCT in the ruptured mitral chordae tendineae was significantly lower compared with the healthy chorda tendinea. Histological examination revealed a change in the components of the connective tissues in ruptured chorda tendinea, in accordance with the low density measured by SR-XPCT. SR-XPCT made it possible to measure tissue density in mitral chordae tendineae. Low density in mitral chordae tendineae is associated with a greater fragility in ruptured mitral chordae tendineae.Keywords
Funding Information
- Japan Society of the Promotion of Science (21K08843)
This publication has 28 references indexed in Scilit:
- Trimodal low-dose X-ray tomographyProceedings of the National Academy of Sciences, 2012
- Optical Properties of In Situ Eye Lenses Measured with X-Ray Talbot Interferometry: A Novel Measure of Growth ProcessesPLOS ONE, 2011
- Local Tenomodulin Absence, Angiogenesis, and Matrix Metalloproteinase Activation Are Associated With the Rupture of the Chordae Tendineae CordisCirculation, 2008
- Recent Advances in X-ray Phase ImagingJapanese Journal of Applied Physics, 2005
- Synchrotron radiation in radiology: novel X-ray sourcesEuropean Radiology, 2003
- Demonstration of X-Ray Talbot InterferometryJapanese Journal of Applied Physics, 2003
- Structure of chordae tendineae in the left ventricle of the human heartJournal of Anatomy, 1998
- Atrioventricular valves of the mouse: III. Collagenous skeleton and myotendinous junctionThe Anatomical Record, 1995
- Morphology and relationship to extensibility curves of human mitral valve chordae tendineae.Circulation Research, 1976
- Canine Mitral Complex: ULTRASTRUCTURE AND ELECTROMECHANICAL PROPERTIESCirculation Research, 1972