Naoto Yagi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Naoto Yagi has a total of 308 co-authors. Here are the top co-authors by number of shared publications:
Katsuaki Inoue
Japan Synchrotron Radiation Institute Spring-8
12 shared publications- Kentaro Uesugi
Japan Synchrotron Radiation Research Institute, Sayo-gun, JAPAN
11 shared publications - Masato Hoshino
Japan Synchrotron Radiation Research Institute, Spectroscopy and Imaging Division, Sayo, Japan
11 shared publications Kentaro Uesugi
Japan Synchrotron Radiation Research Institute, 133704 Sayo-gun, Hyogo Japan
10 shared publications- Tatsuhito Matsuo
Department of Medical Radiology, Faculty of Health and Medical Sciences, Hiroshima International University, Hiroshima, Japan
10 shared publications - Hiroyuki Iwamoto
SPring-8, Japan Synchrotron Radiation Research Institute
8 shared publications
Latest Publications
- Open Access
- 25 April 2025
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 58 (3) , 927-933
A SAXS/WAXD beamline with laboratory SAXS apparatus at NanoTerasu
NanoTerasu is a new 3 GeV synchrotron radiation facility in Sendai, Japan, which began user operation in April 2024. A station for small-angle X-ray scattering (SAXS) and wide-angle X-ray diffraction (WAXD) has been built at the wiggler beamline BL08W. The station was built in a branch for which an X-ray beam is provided by Bragg reflection from two Si crystals. The X-ray energy is 8.0 or 13.1 keV using either an Si(111) or an Si(220) crystal, respectively. The beam is focused with an Ru-coated bent cylindrical mirror. In the SAXS station, an Anton Paar SAXSpoint 5.0 laboratory X-ray apparatus has been installed. The original X-ray generator and focusing mirror in the laboratory equipment were removed and four-quadrant slits and an ion chamber have been installed. Low-scatter slits in SAXSpoint 5.0 are used as guard slits in front of the sample. The X-ray detector is a DECTRIS Eiger2 1M. The slits, sample and detector are enclosed in a vacuum chamber to reduce scattering from the air. The detector can be moved along the X-ray axis under vacuum to change the sample-to-detector distance between 53 and 1610 mm. The X-ray flux at 8.0 keV is 1.0 × 10 11 cps with a ring current of 200 mA, shortening the exposure time by nearly 1000 times compared with the original laboratory X-ray source. The purpose of employing SAXSpoint 5.0 is to provide a user-friendly SAXS/WAXD system. Anton Paar's measurement control system is employed in user operations. Many users utilize a multi-sample holder onto which 20 samples are fixed and measured in turn as programmed. The data analysis software is also provided by Anton Paar, but data can optionally be stored in TIFF format to be processed by any software that users are familiar with. Among the various sample attachments available from Anton Paar, a goniometer stage for grazing-incidence SAXS/WAXD is employed by many users.
- 25 April 2025
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 58 (3) , 927-933
Open AccessA SAXS/WAXD beamline with laboratory SAXS apparatus at NanoTerasu
NanoTerasu is a new 3 GeV synchrotron radiation facility in Sendai, Japan, which began user operation in April 2024. A station for small-angle X-ray scattering (SAXS) and wide-angle X-ray diffraction (WAXD) has been built at the wiggler beamline BL08W. The station was built in a branch for which an X-ray beam is provided by Bragg reflection from two Si crystals. The X-ray energy is 8.0 or 13.1 keV using either an Si(111) or an Si(220) crystal, respectively. The beam is focused with an Ru-coated bent cylindrical mirror. In the SAXS station, an Anton Paar SAXSpoint 5.0 laboratory X-ray apparatus has been installed. The original X-ray generator and focusing mirror in the laboratory equipment were removed and four-quadrant slits and an ion chamber have been installed. Low-scatter slits in SAXSpoint 5.0 are used as guard slits in front of the sample. The X-ray detector is a DECTRIS Eiger2 1M. The slits, sample and detector are enclosed in a vacuum chamber to reduce scattering from the air. The detector can be moved along the X-ray axis under vacuum to change the sample-to-detector distance between 53 and 1610 mm. The X-ray flux at 8.0 keV is 1.0 × 10 11 cps with a ring current of 200 mA, shortening the exposure time by nearly 1000 times compared with the original laboratory X-ray source. The purpose of employing SAXSpoint 5.0 is to provide a user-friendly SAXS/WAXD system. Anton Paar's measurement control system is employed in user operations. Many users utilize a multi-sample holder onto which 20 samples are fixed and measured in turn as programmed. The data analysis software is also provided by Anton Paar, but data can optionally be stored in TIFF format to be processed by any software that users are familiar with. Among the various sample attachments available from Anton Paar, a goniometer stage for grazing-incidence SAXS/WAXD is employed by many users.
- 11 March 2024
- Published by Elsevier in Experimental Eye Research
- Vol. 241, 109858
Optical development in the murine eye lens of accelerated senescence-prone SAMP8 and senescence-resistant SAMR1 strains
- 11 March 2024
- Published by Elsevier in Experimental Eye Research
- Vol. 241, 109858
Optical development in the murine eye lens of accelerated senescence-prone SAMP8 and senescence-resistant SAMR1 strains
- Open Access
- 18 August 2023
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 30 (5) , 995-1002
Structural properties in ruptured mitral chordae tendineae measured by synchrotron-based X-ray phase computed tomography
The link between the structural properties and the rupturing of chordae tendineae in the mitral valve complex is still unclear. Synchrotron-radiation-based X-ray phase computed tomography (SR-XPCT) imaging is an innovative way to quantitatively analyze three-dimensional morphology. XPCT has been employed in this study to evaluate the chordae tendineae from patients with mitral regurgitation and to analyze structural changes in the ruptured chordae tendineae in patients with this condition. Six ruptured mitral chordae tendineae were obtained during surgical repairs for mitral regurgitation and were fixed with formalin. In addition, 12 healthy chordae tendineae were obtained from autopsies. Employing XPCT (effective pixel size, 3.5 µm; density resolution, 1 mg cm−3), the density of the chordae tendineae in each sample was measured. The specimens were subsequently analyzed pathologically. The mean age was 70.2 ± 3.0 in the rupture group and 67.2 ± 14.1 years old in the control group (p = 0.4927). All scans of chorda tendineae with SR-XPCT were performed successfully. The mean densities were 1.029 ± 0.004 in the rupture group and 1.085 ± 0.015 g cm−3 in the control group (p < 0.0001). Density based on SR-XPCT in the ruptured mitral chordae tendineae was significantly lower compared with the healthy chorda tendinea. Histological examination revealed a change in the components of the connective tissues in ruptured chorda tendinea, in accordance with the low density measured by SR-XPCT. SR-XPCT made it possible to measure tissue density in mitral chordae tendineae. Low density in mitral chordae tendineae is associated with a greater fragility in ruptured mitral chordae tendineae.
- 18 August 2023
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 30 (5) , 995-1002
Open AccessStructural properties in ruptured mitral chordae tendineae measured by synchrotron-based X-ray phase computed tomography
The link between the structural properties and the rupturing of chordae tendineae in the mitral valve complex is still unclear. Synchrotron-radiation-based X-ray phase computed tomography (SR-XPCT) imaging is an innovative way to quantitatively analyze three-dimensional morphology. XPCT has been employed in this study to evaluate the chordae tendineae from patients with mitral regurgitation and to analyze structural changes in the ruptured chordae tendineae in patients with this condition. Six ruptured mitral chordae tendineae were obtained during surgical repairs for mitral regurgitation and were fixed with formalin. In addition, 12 healthy chordae tendineae were obtained from autopsies. Employing XPCT (effective pixel size, 3.5 µm; density resolution, 1 mg cm−3), the density of the chordae tendineae in each sample was measured. The specimens were subsequently analyzed pathologically. The mean age was 70.2 ± 3.0 in the rupture group and 67.2 ± 14.1 years old in the control group (p = 0.4927). All scans of chorda tendineae with SR-XPCT were performed successfully. The mean densities were 1.029 ± 0.004 in the rupture group and 1.085 ± 0.015 g cm−3 in the control group (p < 0.0001). Density based on SR-XPCT in the ruptured mitral chordae tendineae was significantly lower compared with the healthy chorda tendinea. Histological examination revealed a change in the components of the connective tissues in ruptured chorda tendinea, in accordance with the low density measured by SR-XPCT. SR-XPCT made it possible to measure tissue density in mitral chordae tendineae. Low density in mitral chordae tendineae is associated with a greater fragility in ruptured mitral chordae tendineae.
- Open Access
High-Resolution X-ray Phase-Contrast Imaging and Sensory and Rheometer Tests in Cooked Edamame
Although several reports exist on the use of X-ray analysis in vegetables and fruits to examine internal disorders, cavities, and porosity, information on X-ray analysis of qualities, such as texture, is lacking as well as information on X-ray analysis of legumes. Therefore, this study aimed to perform X-ray analysis with sensory and rheometer tests in cooked vegetable soybean (edamame). Edamame is popular worldwide due to its deliciousness and nutritional value. Vascular structures and cracks around them were clearly visualized using X-ray phase-contrast computed tomography (CT) imaging. In addition, we observed the fine structure of the seed coat, which could be important for seed development, germination, and processing. The density in the edamame beans declined as the boiling time increased, promoting a reduction in hardness described in sensory and rheometer tests. The reduction in density proceeded from the gap between cotyledons, the opposite side of the hypocotyl, and the crack. Collectively, the findings show that the high-resolution X-ray phase-contrast CT imaging conducted in a nondestructive manner may help in effectively evaluating the quality of vegetables and in observing the internal structures related to plant development.
Open AccessHigh-Resolution X-ray Phase-Contrast Imaging and Sensory and Rheometer Tests in Cooked Edamame
Although several reports exist on the use of X-ray analysis in vegetables and fruits to examine internal disorders, cavities, and porosity, information on X-ray analysis of qualities, such as texture, is lacking as well as information on X-ray analysis of legumes. Therefore, this study aimed to perform X-ray analysis with sensory and rheometer tests in cooked vegetable soybean (edamame). Edamame is popular worldwide due to its deliciousness and nutritional value. Vascular structures and cracks around them were clearly visualized using X-ray phase-contrast computed tomography (CT) imaging. In addition, we observed the fine structure of the seed coat, which could be important for seed development, germination, and processing. The density in the edamame beans declined as the boiling time increased, promoting a reduction in hardness described in sensory and rheometer tests. The reduction in density proceeded from the gap between cotyledons, the opposite side of the hypocotyl, and the crack. Collectively, the findings show that the high-resolution X-ray phase-contrast CT imaging conducted in a nondestructive manner may help in effectively evaluating the quality of vegetables and in observing the internal structures related to plant development.
- Open Access
- 1 August 2020
- Published by Elsevier in Experimental Eye Research
- Vol. 197, 108112
Cell compaction is not required for the development of gradient refractive index profiles in the embryonic chick lens
- 1 August 2020
- Published by Elsevier in Experimental Eye Research
- Vol. 197, 108112
Open AccessCell compaction is not required for the development of gradient refractive index profiles in the embryonic chick lens
- 19 May 2020
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 27 (4) , 934-940
Development of an X-ray imaging detector for high-energy X-ray microtomography
A dedicated X-ray imaging detector for 200 keV high-energy X-ray microtomography was developed. The novelty of the detector is a large-format camera lens employed for a wide field of view. Several scintillators were evaluated in terms of the degree of efficiency of detection for high-energy X-ray photons and the modulation transfer function. For tomographic measurement, a high-definition CMOS camera was incorporated in the detector to achieve a high spatial resolution while keeping the field of view wide. Rocks with fossil inclusions were imaged to demonstrate the applicability of the detector to high-energy X-ray microtomography.
- 19 May 2020
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 27 (4) , 934-940
Development of an X-ray imaging detector for high-energy X-ray microtomography
A dedicated X-ray imaging detector for 200 keV high-energy X-ray microtomography was developed. The novelty of the detector is a large-format camera lens employed for a wide field of view. Several scintillators were evaluated in terms of the degree of efficiency of detection for high-energy X-ray photons and the modulation transfer function. For tomographic measurement, a high-definition CMOS camera was incorporated in the detector to achieve a high spatial resolution while keeping the field of view wide. Rocks with fossil inclusions were imaged to demonstrate the applicability of the detector to high-energy X-ray microtomography.
- Open Access
- 15 May 2020
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 21 (10) , 3520
Crossbridge Recruitment Capacity of Wild-Type and Hypertrophic Cardiomyopathy-Related Mutant Troponin-T Evaluated by X-ray Diffraction and Mechanical Study of Cardiac Skinned Fibers
X-ray diffraction and tension measurement experiments were conducted on rat left ventricular skinned fibers with or without “troponin-T treatment,” which exchanges the endogenous troponin T/I/C complex with exogenous troponin-T. These experiments were performed to observe the structural changes in troponin-T within a fiber elicited by contractile crossbridge formation and investigate the abnormality of hypertrophic cardiomyopathy-related troponin-T mutants. The intensity of the troponin reflection at 1/38.5 nm−1 was decreased significantly by ATP addition after treatment with wild-type or mutant troponin-T, indicating that crossbridge formation affected the conformation of troponin-T. In experiments on cardiac fibers treated with the hypertrophic cardiomyopathy-related mutants E244D- and K247R-troponin-T, treatment with K247R-troponin-T did not recruit contracting actomyosin to a greater extent than wild-type-troponin-T, although a similar drop in the intensity of the troponin reflection occurred. Therefore, the conformational change in K247R-troponin-T was suggested to be unable to fully recruit actomyosin interaction, which may be the cause of cardiomyopathy.
- 15 May 2020
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 21 (10) , 3520
Open AccessCrossbridge Recruitment Capacity of Wild-Type and Hypertrophic Cardiomyopathy-Related Mutant Troponin-T Evaluated by X-ray Diffraction and Mechanical Study of Cardiac Skinned Fibers
X-ray diffraction and tension measurement experiments were conducted on rat left ventricular skinned fibers with or without “troponin-T treatment,” which exchanges the endogenous troponin T/I/C complex with exogenous troponin-T. These experiments were performed to observe the structural changes in troponin-T within a fiber elicited by contractile crossbridge formation and investigate the abnormality of hypertrophic cardiomyopathy-related troponin-T mutants. The intensity of the troponin reflection at 1/38.5 nm−1 was decreased significantly by ATP addition after treatment with wild-type or mutant troponin-T, indicating that crossbridge formation affected the conformation of troponin-T. In experiments on cardiac fibers treated with the hypertrophic cardiomyopathy-related mutants E244D- and K247R-troponin-T, treatment with K247R-troponin-T did not recruit contracting actomyosin to a greater extent than wild-type-troponin-T, although a similar drop in the intensity of the troponin reflection occurred. Therefore, the conformational change in K247R-troponin-T was suggested to be unable to fully recruit actomyosin interaction, which may be the cause of cardiomyopathy.
- Open Access
- 11 May 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (5) , e0233131
Microbeam X-ray diffraction study of lipid structure in stratum corneum of human skin
Human skin, not previously frozen, was studied by small-angle X-ray diffraction. The samples were folded so that a 6μm X-ray beam passed through the top layer of skin, stratum corneum. Diffraction patterns recorded with this method consisted of peaks at about q = 0.5, 1.0 and 1.4 nm-1 in the direction perpendicular to the skin surface more clearly than in previous studies. These peaks are interpreted to arise from lipids between corneocytes. A simple unit of a linear electron density profile with three minima was used to account for the observed intensity profiles. Combinations of calculated diffraction from models with one, two and three units accounted for the major part of the observed diffraction pattern, showing the diversity in the structure of the intercellular lipids.
- 11 May 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (5) , e0233131
Open AccessMicrobeam X-ray diffraction study of lipid structure in stratum corneum of human skin
Human skin, not previously frozen, was studied by small-angle X-ray diffraction. The samples were folded so that a 6μm X-ray beam passed through the top layer of skin, stratum corneum. Diffraction patterns recorded with this method consisted of peaks at about q = 0.5, 1.0 and 1.4 nm-1 in the direction perpendicular to the skin surface more clearly than in previous studies. These peaks are interpreted to arise from lipids between corneocytes. A simple unit of a linear electron density profile with three minima was used to account for the observed intensity profiles. Combinations of calculated diffraction from models with one, two and three units accounted for the major part of the observed diffraction pattern, showing the diversity in the structure of the intercellular lipids.
- Open Access
- 13 February 2020
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 21 (4) , 1244
X-ray Diffraction Studies on the Structural Origin of Dynamic Tension Recovery Following Ramp-Shaped Releases in High-Ca Rigor Muscle Fibers
It is generally believed that during muscle contraction, myosin heads (M) extending from myosin filament attaches to actin filaments (A) to perform power stroke, associated with the reaction, A-M-ADP-Pi → A-M + ADP + Pi, so that myosin heads pass through the state of A-M, i.e., rigor A-M complex. We have, however, recently found that: (1) an antibody to myosin head, completely covering actin-binding sites in myosin head, has no effect on Ca2+-activated tension in skinned muscle fibers; (2) skinned fibers exhibit distinct tension recovery following ramp-shaped releases (amplitude, 0.5% of Lo; complete in 5 ms); and (3) EDTA, chelating Mg ions, eliminate the tension recovery in low-Ca rigor fibers but not in high-Ca rigor fibers. These results suggest that A-M-ADP myosin heads in high-Ca rigor fibers have dynamic properties to produce the tension recovery following ramp-shaped releases, and that myosin heads do not pass through rigor A-M complex configuration during muscle contraction. To obtain information about the structural changes in A-M-ADP myosin heads during the tension recovery, we performed X-ray diffraction studies on high-Ca rigor skinned fibers subjected to ramp-shaped releases. X-ray diffraction patterns of the fibers were recorded before and after application of ramp-shaped releases. The results obtained indicate that during the initial drop in rigor tension coincident with the applied release, rigor myosin heads take up applied displacement by tilting from oblique to perpendicular configuration to myofilaments, and after the release myosin heads appear to rotate around the helical structure of actin filaments to produce the tension recovery.
- 13 February 2020
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 21 (4) , 1244
Open AccessX-ray Diffraction Studies on the Structural Origin of Dynamic Tension Recovery Following Ramp-Shaped Releases in High-Ca Rigor Muscle Fibers
It is generally believed that during muscle contraction, myosin heads (M) extending from myosin filament attaches to actin filaments (A) to perform power stroke, associated with the reaction, A-M-ADP-Pi → A-M + ADP + Pi, so that myosin heads pass through the state of A-M, i.e., rigor A-M complex. We have, however, recently found that: (1) an antibody to myosin head, completely covering actin-binding sites in myosin head, has no effect on Ca2+-activated tension in skinned muscle fibers; (2) skinned fibers exhibit distinct tension recovery following ramp-shaped releases (amplitude, 0.5% of Lo; complete in 5 ms); and (3) EDTA, chelating Mg ions, eliminate the tension recovery in low-Ca rigor fibers but not in high-Ca rigor fibers. These results suggest that A-M-ADP myosin heads in high-Ca rigor fibers have dynamic properties to produce the tension recovery following ramp-shaped releases, and that myosin heads do not pass through rigor A-M complex configuration during muscle contraction. To obtain information about the structural changes in A-M-ADP myosin heads during the tension recovery, we performed X-ray diffraction studies on high-Ca rigor skinned fibers subjected to ramp-shaped releases. X-ray diffraction patterns of the fibers were recorded before and after application of ramp-shaped releases. The results obtained indicate that during the initial drop in rigor tension coincident with the applied release, rigor myosin heads take up applied displacement by tilting from oblique to perpendicular configuration to myofilaments, and after the release myosin heads appear to rotate around the helical structure of actin filaments to produce the tension recovery.
- Open Access
- 31 January 2020
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 76 (2) , 155-165
Development of SPACE-II for rapid sample exchange at SPring-8 macromolecular crystallography beamlines
Reducing the sample-exchange time is a crucial issue in maximizing the throughput of macromolecular crystallography (MX) beamlines because the diffraction data collection itself is completed within a minute in the era of pixel-array detectors. To this end, an upgraded sample changer, SPACE-II, has been developed on the basis of the previous model, SPACE (SPring-8 Precise Automatic Cryo-sample Exchanger), at the BL41XU beamline at SPring-8. SPACE-II achieves one sample-exchange step within 16 s, of which its action accounts for only 11 s, because of three features: (i) the implementation of twin arms that enable samples to be exchanged in one cycle of mount-arm action, (ii) the implementation of long-stroke mount arms that allow samples to be exchanged without withdrawal of the detector and (iii) the use of a fast-moving translation and rotation stage for the mount arms. By pre-holding the next sample prior to the sample-exchange sequence, the time was further decreased to 11 s in the case of automatic data collection, of which the action of SPACE-II accounted for 8 s. Moreover, the sample capacity was expanded from four to eight Uni-Pucks. The performance of SPACE-II has been demonstrated in over two years of operation at BL41XU; the average number of samples mounted on the diffractometer in one day was increased from 132 to 185, with an error rate of 0.089%, which counted incidents in which users could not continue with an experiment without recovery work by entering the experimental hutch. On the basis of these results, SPACE-II has been installed at three other MX beamlines at SPring-8 as of July 2019. The fast and highly reliable SPACE-II is now one of the most important pieces of infrastructure for the MX beamlines at SPring-8, providing users with the opportunity to fully make use of limited beamtime with brilliant X-rays.
- 31 January 2020
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 76 (2) , 155-165
Open AccessDevelopment of SPACE-II for rapid sample exchange at SPring-8 macromolecular crystallography beamlines
Reducing the sample-exchange time is a crucial issue in maximizing the throughput of macromolecular crystallography (MX) beamlines because the diffraction data collection itself is completed within a minute in the era of pixel-array detectors. To this end, an upgraded sample changer, SPACE-II, has been developed on the basis of the previous model, SPACE (SPring-8 Precise Automatic Cryo-sample Exchanger), at the BL41XU beamline at SPring-8. SPACE-II achieves one sample-exchange step within 16 s, of which its action accounts for only 11 s, because of three features: (i) the implementation of twin arms that enable samples to be exchanged in one cycle of mount-arm action, (ii) the implementation of long-stroke mount arms that allow samples to be exchanged without withdrawal of the detector and (iii) the use of a fast-moving translation and rotation stage for the mount arms. By pre-holding the next sample prior to the sample-exchange sequence, the time was further decreased to 11 s in the case of automatic data collection, of which the action of SPACE-II accounted for 8 s. Moreover, the sample capacity was expanded from four to eight Uni-Pucks. The performance of SPACE-II has been demonstrated in over two years of operation at BL41XU; the average number of samples mounted on the diffractometer in one day was increased from 132 to 185, with an error rate of 0.089%, which counted incidents in which users could not continue with an experiment without recovery work by entering the experimental hutch. On the basis of these results, SPACE-II has been installed at three other MX beamlines at SPring-8 as of July 2019. The fast and highly reliable SPACE-II is now one of the most important pieces of infrastructure for the MX beamlines at SPring-8, providing users with the opportunity to fully make use of limited beamtime with brilliant X-rays.