Fully automated laser ablation liquid capture surface analysis using nanoelectrospray ionization mass spectrometry
- 20 April 2014
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 28 (11) , 1312-1320
Abstract
RATIONALE: Laser ablation provides for the possibility of sampling a large variety of surfaces with high spatial resolution. This type of sampling when employed in conjunction with liquid capture followed by nanoelectrospray ionization provides the opportunity for sensitive and prolonged interrogation of samples by mass spectrometry as well as the ability to analyze surfaces not amenable to direct liquid extraction. METHODS: A fully automated, reflection geometry, laser ablation liquid capture spot sampling system was achieved by incorporating appropriate laser fiber optics and a focusing lens into a commercially available, liquid extraction surface analysis (LESA ® )‐ready Advion TriVersa NanoMate system. RESULTS: Under optimized conditions about 10% of laser‐ablated material could be captured in a droplet positioned vertically over the ablation region using the NanoMate robot‐controlled pipette. The sampling spot size area with this laser ablation liquid capture surface analysis (LA/LCSA) mode of operation (typically about 120 µm × 160 µm) was approximately 50 times smaller than that achievable by direct liquid extraction using LESA ® (ca 1 mm diameter liquid extraction spot). The setup was successfully applied for the analysis of ink on glass and paper as well as the endogenous components in Alstroemeria Yellow King flower petals. In a second mode of operation with a comparable sampling spot size, termed laser ablation/LESA ® , the laser system was used to drill through, penetrate, or otherwise expose material beneath a solvent resistant surface. Once drilled, LESA ® was effective in sampling soluble material exposed at that location on the surface. CONCLUSIONS: Incorporating the capability for different laser ablation liquid capture spot sampling modes of operation into a LESA ® ‐ready Advion TriVersa NanoMate enhanced the spot sampling spatial resolution of this device and broadened the surface types amenable to analysis to include absorbent and solvent‐resistant materials. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA.Keywords
This publication has 32 references indexed in Scilit:
- Laser Ablation Sampling of Materials Directly into the Formed Liquid Microjunction of a Continuous Flow Surface Sampling Probe/Electrospray Ionization Emitter for Mass Spectral Analysis and ImagingAnalytical Chemistry, 2013
- Ambient laser ablation sampling for capillary electrophoresis mass spectrometryRapid Communications in Mass Spectrometry, 2013
- Electric‐field‐enhanced collection of laser‐ablated materials onto a solvent bridge for electrospray ionization mass spectrometryRapid Communications in Mass Spectrometry, 2013
- Infrared laser ablation sample transfer for on‐line liquid chromatography electrospray ionization mass spectrometryJournal of Mass Spectrometry, 2012
- Infrared Laser Ablation Atmospheric Pressure Photoionization Mass SpectrometryAnalytical Chemistry, 2012
- Combining transmission geometry laser ablation and a non‐contact continuous flow surface sampling probe/electrospray emitter for mass spectrometry based chemical imagingRapid Communications in Mass Spectrometry, 2011
- Infrared Laser Ablation Sample Transfer for MALDI and ElectrosprayJournal of the American Society for Mass Spectrometry, 2011
- Combining Laser Ablation/Liquid Phase Collection Surface Sampling and High-Performance Liquid Chromatography−Electrospray Ionization-Mass SpectrometryAnalytical Chemistry, 2011
- Laser Ablation Electrospray Ionization for Atmospheric Pressure, in Vivo, and Imaging Mass SpectrometryAnalytical Chemistry, 2007
- Laser desorption‐atmospheric pressure chemical ionization: a novel ion source for the direct coupling of polyacrylamide gel electrophoresis to mass spectrometryJournal of Mass Spectrometry, 2002