The utility of reverse distal femur locking compression plate in minimally invasive osteosynthesis for type C subtrochanteric fractures of the femur: technical description and a clinical series of 50 cases
- 7 September 2021
- journal article
- research article
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 32 (7) , 1423-1433
Abstract
Background Establishing fracture consolidation and avoiding postoperative complications of comminuted subtrochanteric fractures of the femur are technically challenging. The authors delineated a technical description of minimally invasive plate osteosynthesis (MIPO) by using a reverse distal femur locking compression plate (LCP-DF) and retrospectively reviewed the outcomes of these particular fractures. Methods Fifty patients with 51 type C subtrochanteric fractures of the femur were operated on by MIPO and reverse LCP-DF fixation. The collected data included postoperative complications, union times, and clinical outcomes. Results All fractures were united with a mean union time of 19.4 weeks (range 16–22). Regarding postoperative complications, asymptomatic valgus angulation occurred in five patients and trochanteric pain in six. According to Harris hip score, nine patients were determined to be excellent, 36 to be good and five to be fair. Conclusion MIPO by reverse LCP-DF is reliable and effective for type C subtrochanteric fractures of the femur particularly in situations where intramedullary nailing is not feasible.Keywords
This publication has 30 references indexed in Scilit:
- Comparison of proximal femoral nail antirotation (PFNA) with AO dynamic condylar screws (DCS) for the treatment for unstable peritrochanteric femoral fracturesEuropean Journal of Orthopaedic Surgery & Traumatology, 2013
- Reversed anatomic distal femur locking plate for periprosthetic hip fracture fixationOrthopaedics & Traumatology: Surgery & Research, 2011
- Comparison of proximal femoral nail antirotation blade and reverse less invasive stabilization system‐distal femur systems in the treatment of proximal femoral fracturesOrthopaedic Surgery, 2011
- The short-term functional and radiological outcome of patients treated with the Synthes proximal femoral nail antirotation (PFNA) for unstable proximal femoral fracturesEuropean Journal of Orthopaedic Surgery & Traumatology, 2011
- A Biomechanical Analysis of Locking Plate Fixation With Minimally Invasive Plate Osteosynthesis in a Subtrochanteric Fracture ModelJournal of Trauma: Injury, Infection & Critical Care, 2011
- A Biomechanical Comparison of Locked Plate Fixation With Percutaneous Insertion Capability Versus the Angled Blade Plate in a Subtrochanteric Fracture Gap ModelJournal of Orthopaedic Trauma, 2009
- Technical aspects of the use of dynamic condylar screw in biological fixation of comminuted subtrochanteric fracturesEuropean Journal of Orthopaedic Surgery & Traumatology, 2008
- Reverse LISS plating for proximal segmental femoral fractures in the polytrauma patient: A case reportInjury, 2007
- Treatment of subtrochanteric fractures. A comparison of the Gamma nail and the dynamic hip screw: short-term outcome in 58 patientsInternational Orthopaedics, 2006
- The use of a dynamic condylar screw and biological reduction techniques for subtrochanteric femur fractureInjury, 2003