SJSurasak Jitprapaikulsarn

Surasak Jitprapaikulsarn

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Surasak Jitprapaikulsarn has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A simplified protocol using septocutaneous perforator-based propeller flaps for concurrent fixation and coverage of complex ankle and hindfoot fractures

    by Pissanu Reingrittha, Areeya Kamphaengkaew, Surasak Jitprapaikulsarn, Artit Manoprasertkul, Pasit Sengpanich, Ployphailin Rungsakaolert

  • Open Access

    Torsional Stability of the Femoral Neck System for Pauwels Type III Femoral Neck Fracture Fixation: A Finite-element Analysis

    by Nattapon Chantarapanich, Surasak Jitprapaikulsarn, Banchong Mahaisavariya, Chantas Mahaisavariya

    Introduction: Femoral neck fracture fixation remains challenging, particularly for Pauwels type III fractures that require robust implants to withstand vertical shear forces. The femoral neck system (FNS) offers greater stiffness and more stable load sharing than multiple screw fixation; however, it has a lower load-to-failure than plate systems. We evaluated the torsional stability of the FNS using finite-element analysis. Methods: We analyzed a transcervical Pauwels type III femoral neck fracture without a fracture gap, fixed with one of three constructs: multiple screw fixation, a dynamic hip screw (DHS) with an antirotation screw, or an FNS. Finite-element simulations incorporated muscle forces during the leg-swing phase, with constraints applied at the fovea capitis. Cortical-cancellous interfaces were fully bonded, except at the reduced fracture interface where relative translation was allowed. Results: The DHS with an antirotation screw had the highest equivalent von Mises stress and strain energy density (SED) (1130.11 MPa/1,000) and the greatest fragment displacement (0.44 mm). Multiple screw fixation produced the lowest SED (151.73 MPa/1,000), and the FNS showed similar displacement with an intermediate SED (201.96 MPa/1,000). In the FNS, peak stress localized near the lateral cortex of the proximal femur, with reduced stress at the barrel-screw interface. Conclusions: The FNS provides rotational stability for Pauwels type III fractures comparable with multiple screw fixation and reduces stress at the fracture site. The DHS with an antirotation screw was less stable during hip rotation. Given its greater compressive strength than multiple screw fixation, the FNS is the preferred fixation option.

  • Roles of a nonvascularized fibular graft with and without fixation in the treatment of segmental tibial bone loss: A finite element analysis

    by Surasak Jitprapaikulsarn, Nattapon Chantarapanich, Theerachai Apivatthakakul, Chantawat Ruchawapol, Arthit Gromprasit, Pasit Sengpanich, Chantas Mahaisavariya, Ravisara Sukhan

  • Dual tension band wiring for adolescent supracondylar fractures of the humerus: mechanical assessment and a clinical series

    by Surasak Jitprapaikulsarn, Nattapon Chantarapanich, Theerachai Apivatthakakul, Pasin Lertvilai, Sujin Wanchat, Arthit Gromprasit, Pasit Sengpanich, Chantas Mahaisavariya, Yotakarn Saramas, Louis Paul Simonet

    Background The optimal fixation technique of adolescent supracondylar fractures of the humerus (A-SCFH) remains inconclusive. To prove the efficacy of Dual Tension Band Wiring (DTBW), the mechanical performance was compared to the other pinning constructs, i.e., Lateral Divergent Pining (LDP), Cross Pining (CP) and Dual CP. The clinical outcomes of the DTBW in A-SCFH were retrospectively described. Methods Bone specimens with a supracondylar fracture acquired from computed tomography images of a patient were fabricated using a three-dimensional printing technique. The fracture was stabilized with pining techniques to create those four constructs. Each of constructs was mechanically tested under posterior bending, medial bending, lateral bending, and torsion. Maximum force, displacement at maximum force, maximum torque, rotational displacement at maximum torque, and construct stiffness were collected and calculated from the result of mechanical test. For the case series, 15 A-SCFH was operated on the DTBW. The reviewed data included time to union, perioperative complications, arc of elbow motion, Mayo Elbow Performance Score (MEPS) and Disabilities of the Arm, Shoulder and Hand (DASH) score. Results The DTBW revealed a greater maximum force, and construct stiffness compared to the other constructs in most of the loading conditions. According to the case series, all fractures were consolidated with a mean union time of 7.2 weeks (range 6–10). By MEPS, all patients were determined to be good-to-excellent. The mean arc of elbow motion was 130 degrees (range 120–140) with a mean DASH score of 7.9 (range 2.5–17.5). Conclusion By mechanical performance and clinical outcomes, the DTBW can be an effective and reliable technique in management of A-SCFH.


  • How wide of a distal metaphyseal femoral fracture gap is a high risk of varus collapse and fixation failure? A finite element study

    by Surasak Jitprapaikulsarn, Nattapon Chantarapanich, Theerachai Apivatthakakul, Pasin Lertvilai, Sujin Wanchat, Arthit Gromprasit, Pasit Sengpanich, Chantas Mahaisavariya


  • Concurrent plate fixation and pedicled flap coverage for open fractures complicated by soft tissue loss of the tibia in pediatric cohort: a clinical series

    by Surasak Jitprapaikulsarn, Pasit Sengpanich, Ployphailin Rungsakaolert, Kritsada Sukha, Pissanu Reingrittha, Arthit Gromprasit

    Background The optimal treatment of open fractures complicated by soft tissue loss of pediatric tibial fractures remains inconclusive. The author described a protocol of concurrent plate fixation and pedicled flap coverage and retrospectively reviewed the outcomes of such injuries. Methods A total of 25 pediatric cases with Gustilo lllB open tibial fracture were treated by single-stage plate fixation and pedicled flap reconstruction. The reviewed information consisted of time to fix and flap, type of plate, type of pedicled flap, fracture union time, postoperative complication and the clinical outcomes by objective scoring system. Results Fix and flap was undergone between 7 and 12 days after injury with the average time of 8.2 days. Regarding the type of plate, narrow LCP was applied in 8, 3.5 mm precontoured LCP in 10, 5.0 mm precontoured in 2 and double LCP in 5. According to soft tissue reconstruction, the medial gastrocnemius flap was selected in 6 cases, myocutaneous medial gastrocnemius flap in 2, soleus flap in 3, hemisoleus flap in 5, reverse sural flap in 6 and combined medial gastrocnemius and hemisoleus flaps in 3. No flap-related complication was demonstrated. All cases established fracture union in between 12 and 24 weeks with an average time to union of 17.7 weeks. According to postoperative complications, infected plate occurred in 2 cases and implant irritation in 5. According to Puno functional score, excellent results were presented in 7 cases and good results in 18 cases. Conclusion Single-stage plate fixation and pedicled flap coverage are a reliable regimen for pediatric open fractures complicated by soft tissue loss of the tibia.


  • Open Access

    Torsional stability of fixation methods in basicervical femoral neck fractures: a biomechanical study

    by Chantas Mahaisavariya, Surasak Jitprapaikulsarn, Banchong Mahaisavariya, Nattapon Chantarapanich

    Background: Basicervical femoral neck fracture is a rare proximal femur fracture with a high implant failure rate. Biomechanical comparisons between cephalomedullary nails (CMNs) and dynamic hip screws (DHSs) under torsion loading are lacking. This study compared the biomechanical performance of three fixations for basicervical femoral neck fractures under torsion load during early ambulation. Methods: The biomechanical study models used three fixations: a DHS, a DHS with an anti-rotation screw, and a short CMN. Finite element analysis was used to simulate hip rotation with muscle forces related to leg swing applied to the femur. The equivalent von Mises stress (EQV) on fixation, fragment displacement, and strain energy density at the proximal cancellous bone were monitored for fixation stability. Results: The EQV of the short CMN construct (304.63 MPa) was comparable to that of the titanium DHS construct (293.39 MPa) and greater than that of the titanium DHS with an anti-rotation screw construct (200.94 MPa). The proximal fragment displacement in the short CMN construct was approximately 0.13 mm, the greatest among the constructs. The risk of screw cutout for the lag screw in short CMNs was 3.1–5.8 times greater than that for DHSs and DHSs with anti-rotation screw constructs. Conclusions: Titanium DHS combined with an anti-rotation screw provided lower fragment displacement, stress, and strain energy density in the femoral head than the other fixations under torsion load. Basicervical femoral neck fracture treated with CMNs may increase the risk of lag screw cutout. Graphical


  • Simultaneous internal fixation and latissimus dorsi pedicle flap coverage: A reliable regimen for open fractures with accompanying sizable soft tissue loss of the upper extremities

    by Surasak Jitprapaikulsarn, Chawanan Patamamongkonchai, Kritsada Sukha, Arthit Gromprasit, Witoon Thremthakanpon

  • Minimally invasive plate osteosynthesis via posterior approach for type B and C fractures of distal humeral shaft: surgical tactics and a clinical series

    by Surasak Jitprapaikulsarn, Arthit Gromprasit, Kritsada Sukha, Chawanan Patamamongkonchai, Chittawee Jiamton

    The optimal technique and implant for fixation of multifragmentary fractures of the distal humeral shaft remain inconclusive. We describe the use of minimally invasive plate osteosynthesis (MIPO) via posterior approach and extra-articular distal humerus locking compression plate (LCP-EADH) fixation for 18 such fractures. All fractures were united with a mean union time of 17.6 weeks (range 12–20). Transient radial nerve palsy was demonstrated in 2 patients. Six patients had 5° varus angulation and 1 had 5° valgus angulation. Triceps power was Grade 5 in all patients. The mean arc of elbow motion was 127.5 degrees (range 115–140). Six patients had an excellent MEP score and 12 had a good MEP score. As the results, posterior MIPO and LCP-EADH fixation could be an alternative for multifragmentary fractures of the distal humeral shaft, particularly for fractures with a very short distal fragment.


  • The utility of reverse distal femur locking compression plate in minimally invasive osteosynthesis for type C subtrochanteric fractures of the femur: technical description and a clinical series of 50 cases

    by Surasak Jitprapaikulsarn, Arthit Gromprasit, Kritsada Sukha, Chawanan Patamamongkonchai, Apipop Kritsaneephaiboon

    Background Establishing fracture consolidation and avoiding postoperative complications of comminuted subtrochanteric fractures of the femur are technically challenging. The authors delineated a technical description of minimally invasive plate osteosynthesis (MIPO) by using a reverse distal femur locking compression plate (LCP-DF) and retrospectively reviewed the outcomes of these particular fractures. Methods Fifty patients with 51 type C subtrochanteric fractures of the femur were operated on by MIPO and reverse LCP-DF fixation. The collected data included postoperative complications, union times, and clinical outcomes. Results All fractures were united with a mean union time of 19.4 weeks (range 16–22). Regarding postoperative complications, asymptomatic valgus angulation occurred in five patients and trochanteric pain in six. According to Harris hip score, nine patients were determined to be excellent, 36 to be good and five to be fair. Conclusion MIPO by reverse LCP-DF is reliable and effective for type C subtrochanteric fractures of the femur particularly in situations where intramedullary nailing is not feasible.