Abstract
The differential transformer is an important component in the front-end electronics of high-precision capacitive position sensing circuits, which are widely employed in space inertial sensors and electrostatic accelerometers. The position sensing offset, one of the space inertial sensors’ most critical error sources in the performance range, is dominated by the differential transformer asymmetry and requires a high-precision evaluation. This paper proposes a method to assess differential transformers’ asymmetry and realize a prototype circuit to test a transformer sample. The results show that the asymmetry measurement precision can achieve 0.6 ppm for the transformer with an asymmetry level of about −278.2 ppm.
Funding Information
  • National Natural Science Foundation of China (11727814)
  • National Natural Science Foundation of China (41874217)
  • National Natural Science Foundation of China (42274229)
  • National Key Research and Development Program of China (2020YFC2200803)
  • National Key Research and Development Program of China (2020YFC2200702)

This publication has 18 references indexed in Scilit: