DCDecong Chen

Decong Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Decong Chen has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Finite element analysis for the measurement error of electrostatic accelerometer due to the electrode misalignment

    by Mi Tang, Shaobo Qu, Yanchong Liu, Decong Chen, Shuang Hu, Li Liu, Yanzheng Bai, Shuchao Wu, Zebing Zhou

    The electrostatic accelerometer is the key payload of many space missions, such as satellite gravity measurements, space gravitational experiments, with a typical precision requirement from nano-g to femto-g. The measurement error model analysis is an important issue for the electrostatic accelerometer with numerous error sources. The traditional method by theoretical analysis is complicated to evaluate the complete measurement error models quantitatively especially when the machining and assembly errors of the sensor head are considered. Limited by the earth gravity and seismic noise which is much higher than the intrinsic noise, the complete error model of electrostatic accelerometers can also hardly be tested on ground. In this paper, the method by using finite element analysis of the sensor head is studied. The simulation model for an electrostatic accelerometer sensor head is built, and the multi-conductor capacitance matrix data is simulated. The accuracy of the capacitance simulation is evaluated in three ways including the convergence check of the capacitance with the mesh size, the symmetry verification, and the sensitivity comparison with the theoretical model. Finally, the accelerometer measurement model is analyzed based on the simulation data, using the case of rotating installation misalignment of the upper electrode as an example. The measurement model and error items of one horizontal axis and one rotating axis are quantitatively evaluated. The method proposed in this paper provide a new effective approach to the measurement model analysis of the electrostatic accelerometers in complex working scenarios both in orbit and on ground, which could be helpful to enhance the performance and the efficiency of application.


  • Open Access

    A method for high-precision measuring differential transformer asymmetry

    by Xiao-Tian Yang, Ming Hu, Cheng-Rui Wang, Duo Li, De-Cong Chen, Chao-Li Ouyang, Yan-Zheng Bai, Shao-Bo Qu, Ze-Bing Zhou

    The differential transformer is an important component in the front-end electronics of high-precision capacitive position sensing circuits, which are widely employed in space inertial sensors and electrostatic accelerometers. The position sensing offset, one of the space inertial sensors’ most critical error sources in the performance range, is dominated by the differential transformer asymmetry and requires a high-precision evaluation. This paper proposes a method to assess differential transformers’ asymmetry and realize a prototype circuit to test a transformer sample. The results show that the asymmetry measurement precision can achieve 0.6 ppm for the transformer with an asymmetry level of about −278.2 ppm.


  • Open Access

    Bias Stability Investigation of a Triaxial Navigation-Compatible Accelerometer with an Electrostatic Spring

    by Decong Chen, Yanzheng Bai, Chengrui Wang, Shuchao Wu, Chunyu Xiao, Jianbo Yu, Zebing Zhou

    The bias stability performance of accelerometers is essential for an inertial navigation system. The traditional pendulous accelerometer usually has a flexible connection structure, which could limit the long-term bias stability. Here, based on the main technologies employed in previous space missions of our group, we developed a terrestrial triaxial navigation-compatible accelerometer. Because there is no mechanical connection between the inertial test mass and the frame, the bias performance relies on the stability of the equivalent electrostatic spring, where further sources are analyzed to get the optimal electrostatic force scheme. To investigate the bias stability under different ranges, the vertical and horizontal measurement ranges are designed at 5 g and ±10 mg, respectively. A low-noise high-voltage levitation scheme is adopted to extend the vertical measurement range from sub-mg to more than earth’s 1-g gravity. Finally, the experimental validation results show that the 24-h bias stability of vertical and two horizontal directions come to 13.8 μg, 0.84 μg, and 0.77 μg, respectively.