A new approach for multislice spatiotemporal encoding MRI in a portable low‐field system
- 20 September 2024
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (2) , 709-717
Abstract
Purpose: Spatiotemporal encoding (SPEN) MRI offers a unique alternative to address image distortion problems in echo planar acquisition‐based techniques, at portable low‐field systems that lack multiple receiver coils. However, existing 2‐π multislice SPEN schemes fail to keep consistent SNRs and contrasts with different numbers of slice settings. This work proposes a new multislice SPEN scheme (SPENms) to achieve stable quality imaging in portable low‐field MRI systems.Methods: The proposed SPENms includes the insertion of one selective π pulse and one non‐selective π pulse, closely arranged together, before the frequency‐swept π pulse in the original 2D SPEN sequence. Theoretical simulations and experiments on phantoms and human brains were conducted to validate its SNR and contrast performances under different parameters compared to the existing 2‐π multislice SPEN scheme.Results: Both simulations and experiments demonstrate the consistent image quality of SPENms with different scanning parameters and targets, as well as good distortion resistance and scan efficiency. Robust diffusion weighted multislice SPEN images of diagnostic value were also highlighted.Conclusion: SPENms provides a robust fast echo planar acquisition approach to obtain multislice 2D images with less distortions, consistent SNRs and contrasts at portable low‐field MRI systems.Keywords
Funding Information
- National Natural Science Foundation of China (62301309)
- Israel Science Foundation (3594/21)
This publication has 30 references indexed in Scilit:
- Low‐field MRI: Clinical promise and challengesJournal of Magnetic Resonance Imaging, 2022
- Assessment of Brain Injury Using Portable, Low-Field Magnetic Resonance Imaging at the Bedside of Critically Ill PatientsJAMA Neurology, 2021
- In vivo 3D brain and extremity MRI at 50 mT using a permanent magnet Halbach arrayMagnetic Resonance in Medicine, 2020
- B0 field homogeneity recommendations, specifications, and measurement units for MRI in radiation therapyMedical Physics, 2020
- Multi‐shot diffusion‐weighted MRI reconstruction with magnitude‐based spatial‐angular locally low‐rank regularization (SPA‐LLR)Magnetic Resonance in Medicine, 2019
- Reducing SAR requirements in multislice volumetric single‐shot spatiotemporal MRI by two‐dimensional RF pulsesMagnetic Resonance in Medicine, 2016
- Single‐scan MRI with exceptional resilience to field heterogeneitiesMagnetic Resonance in Medicine, 2016
- New spatiotemporal approaches for fully refocused, multislice ultrafast 2D MRIMagnetic Resonance in Medicine, 2013
- RASER: A new ultrafast magnetic resonance imaging methodMagnetic Resonance in Medicine, 2007
- Clinical multishot DW‐EPI through parallel imaging with considerations of susceptibility, motion, and noiseMagnetic Resonance in Medicine, 2007