ZZZhiyong Zhang

Zhiyong Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhiyong Zhang has a total of 80 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of basis choice on quantitative parameter estimation in accelerated subspace reconstructions

    by Haoran Bai, Ke Dai, Yueqi Qiu, Jianfeng Bao, Xiao Wang, Yong Zhang, Hao Chen, Zhiyong Zhang, Philip K. Lee

    This work assesses the effects of different simulated and data-driven subspaces on quantitative parameter estimation in highly accelerated subspace reconstructions. Three different methods for generating basis were applied in a locally low rank subspace reconstruction: (1) a data-driven basis derived from fully sampled low-resolution data, (2) a simulated basis from a dictionary with uniform T2 tissue distribution, and (3) a simulated basis with white matter (WM) and gray matter (GM) oversampled. Obtaining basis vectors from a dictionary with non-uniform tissue distributions can be interpreted as obtaining basis vectors using a weighted singular value decomposition to a dictionary generated with uniform tissue spacings. Fully sampled echo planar spectroscopic imaging (EPSI) datasets of six subjects (including three brain tumor patients) were retrospectively undersampled with 9-shot and 3-shot ky-t traversals. The effect of regularization was assessed by comparing T2 maps and qualitative images of fully sampled and retrospectively undersampled images. Under 3-shot retrospective undersampling, images reconstructed with the basis generated from a uniform T2 distribution basis had altered signal evolutions, resulting in statistically significant WM/GM T2 overestimations with mean differences of 10–15 ms. Applying a WM/GM oversampled basis improved T2 accuracy but still induced T2 bias. The data-driven basis provided the most accurate T2 estimates. Highly accelerated subspace reconstructions cause bias in quantitative relaxation maps. Data-driven subspaces can reduce this bias.

  • Diffusion Weighted Fast Spin Echo With RF ‐Encoded Slabs for Portable Low‐Field MRI Systems

    by Philip K. Lee, Yueqi Qiu, Suen Chen, Changyue Wang, Zhiyong Zhang

    Purpose: To develop a robust diffusion weighted (DW) acquisition with clinically feasible scan times for portable MRI systems. Methods: A linear reconstruction model including: tailored RF‐encoding schemes, motion‐induced phases, and systematic phase errors was developed for slab diffusion weighted fast spin echo (FSE) data acquired with quadratic phase increment. Systematic phases imparted by diffusion gradients were obtained using a calibration phantom. Trace‐weighted DW‐FSE was compared to DW‐EPI in vivo on a portable 110 mT H‐based system. A high‐NEX DW‐FSE acquisition was performed in healthy volunteers followed by Monte Carlo retrospective undersampling to evaluate expected image quality and mean diffusivity variation in a DWI protocol with clinically feasible scan times. Results: CPMG calibration and polynomials fitted to systematic phase errors enabled accurate estimation of motion‐induced phases. Accounting of different phase sources reduced ghosting artifacts and improved SNR efficiency by enabling RF‐encoding. RF‐encoded slab DW‐FSE obtained in vivo trace‐weighted images without distortion artifacts and with voxel sizes 5× smaller than DW‐EPI. The retrospectively undersampled acquisition showed that 12 cm slice coverage with voxel size 2.5 × 2.5 × 5 mm 3 could be achieved in 12 min scan time. The mean diffusivity standard deviation between Monte Carlo trials was 0.2 × 10 −3 mm 2 /s. Conclusion: Diffusion weighted FSE is a robust, distortionless approach for high SNR efficiency DWI on portable MRI systems. Multiband quadratic phase increment DW‐FSE leverages the low SAR and higher peak B 1 provided by low field strengths and is less dependent on performant hardware compared to DW‐EPI.

  • Rapid quantitative susceptibility mapping using single-shot echo planar time-resolved imaging

    by Haoran Bai, Ke Dai, Zhenghao Li, Eddy Solomon, Hongjiang Wei, Zhouwei Xu, Hao Chen, Zhiyong Zhang

    Objective. Echo-planar imaging (EPI) can provide rapid quantitative susceptibility mapping (QSM) in single-shot acquisition but suffers from B 0 inhomogeneity and susceptibility artifacts near air–tissue interfaces. To address these limitations, this work introduces single-shot echo planar time-resolved imaging (EPTI), which enables distortion-free and multi-contrast imaging for rapid QSM. Approach. A zig-zag k y –t sampling trajectory was employed in two-dimensional single-shot EPTI and a locally low-rank subspace reconstruction with B 0 updating was applied to generate distortion-free multi-echo images from highly undersampled data. The proposed EPTI-QSM method was systematically evaluated against the gold-standard three-dimensional (3D) gradient echo (GRE) and single-shot EPI with a uniform 4-step masking procedure. In addition, various echo selections from the EPTI images were investigated to assess their impact on QSM quality. Main Results. EPTI-QSM demonstrated better anatomical fidelity, reduced susceptibility artifacts, and a reliable brain coverage compared to single-shot EPI, particularly in regions affected by B 0 inhomogeneity. Multi-echo EPTI data with echo times ranging from 10 to 30 ms further improved susceptibility quantification and mitigated signal dropouts near air–tissue interfaces. In addition, EPTI yielded distortion-free structural images compared to EPI, and improved image contrast compared to 3D GRE used for QSM, enabling clearer anatomical visualization. Significance. Single-shot EPTI enables distortion-free, multi-contrast images and rapid QSM reconstruction, offering a promising alternative to EPI-based QSM, particularly in applications requiring rapid and robust susceptibility quantification.

  • Deep learning-driven contactless ECG in MRI via beat pilot tone for motion-resolved image reconstruction and heart rate monitoring

    by Haoyu Sun, Qichen Ding, Sijie Zhong, Zhiyong Zhang

    Objective. Electrocardiogram (ECG) is crucial for synchronizing cardiovascular magnetic resonance imaging (CMRI) acquisition with the cardiac cycle and for continuous heart rate monitoring during prolonged scans. However, conventional electrode-based ECG systems in clinical MRI environments suffer from tedious setup, magnetohydrodynamic (MHD) waveform distortion, skin burn risks, and patient discomfort. This study proposes a contactless ECG measurement method in MRI to address these challenges. Approach. We integrated beat pilot tone (BPT)—a contactless, high motion sensitivity, and easily integrable RF motion sensing modality—into CMRI to capture cardiac motion without direct patient contact. A deep neural network was trained to map the BPT-derived cardiac mechanical motion signals to corresponding ECG waveforms. The reconstructed ECG was evaluated against simultaneously acquired ground truth ECG through multiple metrics: Pearson correlation coefficient, relative root mean square error cardiac trigger timing accuracy, and heart rate estimation error. Additionally, we performed MRI retrospective binning reconstruction using reconstructed ECG reference and evaluated image quality under both standard clinical conditions and challenging scenarios involving arrhythmias and subject motion. To examine scalability of our approach across field strength, the model pretrained on 1.5T data was applied to 3T BPT cardiac acquisitions. Main Results. In optimal acquisition scenarios, the reconstructed ECG achieved a median Pearson correlation of 89% relative to the ground truth, while cardiac triggering accuracy reached 94%, and heart rate estimation error remained below 1 bpm. The quality of the reconstructed images was comparable to that of ground truth synchronization. The method exhibited a degree of adaptability to irregular heart rate patterns and subject motion, and scaled effectively across MRI systems operating at different field strengths. Significance. The proposed contactless ECG measurement method has the potential to streamline CMRI workflows, improve patient safety and comfort, mitigate MHD distortion challenges and find a robust clinical application.

  • High‐Accelerated Parallel Imaging With the Inherent Local Feature in PE ‐ xSPEN MRI

    by Ke Dai, Eddy Solomon, Philip K. Lee, Guangyu Tao, Yueqi Qiu, Hao Chen, Lucio Frydman, Zhiyong Zhang

    Purpose: To achieve highly accelerated high‐resolution imaging with PE‐xSPEN that efficiently utilizes the spatiotemporal encoded signals to physically distinguish contributions from distinct spatial locations prior to k‐space acquisition, enabling the differentiation of aliased localized information in k‐space. Methods: In the conventional k‐space, undersampling along the phase‐encoding dimension results in aliasing and overlapping replicas of the object along the spatial direction. The modulated hyperbolic phase arising from the PE‐xSPEN encoding induces coupling between the and dimensions. So that for a given k‐space location, the signal is predominantly contributed by local voxels. While undersampling along the PE dimension still causes aliased spatial replicas, these replicas remain distinguishable even without multi‐channel coils after applying the traditional inverse Fourier transform along the undersampled dimension. Combining with parallel imaging, this approach enhances unfolding efficiency compared to traditional Fourier‐encoded signals. Results: Combining with GRAPPA, the undersampled signals along the dimension can be reconstructed with fewer residual aliasing in PE‐xSPEN compared to the traditional Fourier‐encoded signals. The performance gain is demonstrated by MRI simulation, phantom tests, and in vivo brain experiments on 3T scanner. Conclusion: The proposed PE‐xSPEN GRAPPA framework utilizes hyperbolic phase modulation to control aliasing artifacts and generate ‐dependent coil response, reducing artifacts and noise amplification.

  • Multiband Fast Spin Echo on portable low‐field systems

    by Philip K. Lee, Yueqi Qiu, Changyue Wang, Zhiyong Zhang

    Purpose: To improve the SNR efficiency of Fast Spin Echo (FSE) using RF‐encoded multiband imaging and to develop techniques that correct artifacts from non‐Carr–Purcell–Meiboom–Gill (CPMG) magnetization arising from system imperfections. Methods: Optimal refocusing pulse band phase modulations that satisfy the CPMG condition were calculated for different multiband factors. Fast recovery was used to enhance T2 contrast. Quadratic phase refocusing pulses, phase encode and slice select gradient reshaping, and zeroth‐order phase calibrations were tested to reduce residual non‐CPMG magnetization. Image contrast of T2‐weighted and T1‐weighted imaging and SNR improvements were evaluated in phantom and in vivo experiments on an in‐house portable 110 mT system. Results: The peak of multiband refocusing pulses using the obtained optimal phase modulations varies closely with the expected increase of . Modulations satisfying the CPMG phase condition provide similar peak reductions to previously proposed subband modulation schemes. Quadratic phase increment reduced shading from residual non‐CPMG magnetization, and bipolar phase encoding reduced residual ghosting. Zeroth‐order RF phase calibrations on the excitation and tipup, and slice select reshaping that minimized residual phase on 2D maps calculated from even and odd echo images improved contrast with long T2 species. RF‐encoded multiband FSE improved SNR by a factor close to the theoretical expected improvement of . Conclusion: RF‐encoded multiband imaging is a viable approach for improving SNR efficiency on low‐field portable systems.


  • Open Access

    Experience of how to build an MRI machine from scratch

    by Shaoying Huang, José Miguel Algarín, Joseba Alonso, R Anieyrudh, Jose Borreguero, Fabian Bschorr, Paul Cassidy, Wei Ming Choo, David Corcos, Teresa Guallart-Naval, et al.


  • Open Access

    ezyMRI: How to build an MRI machine from scratch -- Experience from a four-day hackathon

    by Shaoying Huang, José Miguel Algarín, Joseba Alonso, Anieyrudh R, Jose Borreguero, Fabian Bschorr, Paul Cassidy, Wei Ming Choo, David Corcos, Teresa Guallart-Naval, et al.

    Nuclear magnetic resonance instruments are becoming available to the do-it-yourself community. The challenges encountered in the endeavor to build a magnetic resonance imaging instrument from scratch were confronted in a four-day hackathon at Singapore University of Technology and Design in spring 2024. One day was devoted to educational lectures and three days to system construction and testing. Seventy young researchers from all parts of the world formed six teams focusing on magnet, gradient coil, RF coil, console, system integration, and design, which together produced a working MRI instrument in three days. The different steps, encountered challenges, and their solutions are reported.


  • A new approach for multislice spatiotemporal encoding MRI in a portable low‐field system

    by Yueqi Qiu, Suen Chen, Eddy Solomon, Changyue Wang, Sijie Zhong, Ke Dai, Hao Chen, Lucio Frydman, Zhiyong Zhang

    Purpose: Spatiotemporal encoding (SPEN) MRI offers a unique alternative to address image distortion problems in echo planar acquisition‐based techniques, at portable low‐field systems that lack multiple receiver coils. However, existing 2‐π multislice SPEN schemes fail to keep consistent SNRs and contrasts with different numbers of slice settings. This work proposes a new multislice SPEN scheme (SPENms) to achieve stable quality imaging in portable low‐field MRI systems.Methods: The proposed SPENms includes the insertion of one selective π pulse and one non‐selective π pulse, closely arranged together, before the frequency‐swept π pulse in the original 2D SPEN sequence. Theoretical simulations and experiments on phantoms and human brains were conducted to validate its SNR and contrast performances under different parameters compared to the existing 2‐π multislice SPEN scheme.Results: Both simulations and experiments demonstrate the consistent image quality of SPENms with different scanning parameters and targets, as well as good distortion resistance and scan efficiency. Robust diffusion weighted multislice SPEN images of diagnostic value were also highlighted.Conclusion: SPENms provides a robust fast echo planar acquisition approach to obtain multislice 2D images with less distortions, consistent SNRs and contrasts at portable low‐field MRI systems.