Long-Term Afterglow Measurement of Scintillators after Gamma Irradiation
Open Access
- 5 October 2024
- journal article
- research article
- Published by MDPI AG in Journal of Nuclear Engineering
- Vol. 5 (4) , 436-444
Abstract
The long-term afterglow of scintillators is an important aspect, especially when the light signal from a scintillator is evaluated in the current mode. Scintillators used for radiation detection exhibit an afterglow, which usually comes from multiple components that have different decay times. A high level of afterglow usually has a negative influence on the detection parameters for the energy resolution in spectrometry measurements or X-ray and neutron imaging. The paper deals with the long-term afterglow of some types of scintillators, which is more significant for integral measurement when the current is measured in a photodetector. The range of decay times studied was in the order of tens of seconds to days. Seven types of scintillators were examined: BGO, CaF2(Eu), CdWO4, CsI(Tl), LiI(Eu), NaI(Tl), and plastic scintillator. The scintillators were excited by gamma-ray radiation. After irradiation, the detection unit, along with the scintillator, was moved to a laboratory where the anode current of the photomultiplier tube was measured using a picoammeter for at least a day. The measurements showed that CdWO4 and plastic scintillators have relatively low long-term afterglow signals in comparison to the other scintillators studied.Keywords
Funding Information
- Ministry of Education, Youth and Sports (LM2018120, LM2023041)
This publication has 13 references indexed in Scilit:
- LONG-TERM AFTERGLOW OF SOLID SCINTILLATORSRadiation Protection Dosimetry, 2022
- 3D RECONSTRUCTION OF INNER STRUCTURE OF RADIOACTIVE SAMPLES UTILIZING GAMMA TOMOGRAPHYRadiation Protection Dosimetry, 2019
- Materials for Solid State Lighting and Displays2016
- Thermal Neutron Filter Design for the Neutron Radiography Facility at the LVR-15 ReactorIEEE Transactions on Nuclear Science, 2016
- Low-Afterglow Scintillators for High-Rate Radiation Detection2015
- Recent R&D Trends in Inorganic Single‐Crystal Scintillator Materials for Radiation DetectionAdvanced Optical Materials, 2015
- On the elimination of the afterglow of CsI(Tl) scintillation detectorNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2009
- Energy Resolution of Scintillation Detectors—New ObservationsIEEE Transactions on Nuclear Science, 2008
- Afterglow in LSO and its possible effect on energy resolutionIEEE Transactions on Nuclear Science, 2000
- THE DETECTION OF SCINTILLATIONS1964