Ladislav Viererbl
Research Subjects
Research Interests
Ladislav Viererbl has a total of 255 co-authors. Here are the top co-authors by number of shared publications:
M. Marek
19 shared publications- Michal Koleska
Research Centre Rež Ltd., Husinec-130, Rež 250 68, Czech Republic
12 shared publications V. Klupak
Department of Neutron Physics, Research Centre Řež, Czech Republic
12 shared publicationsJ. Burian
11 shared publicationsZ. Lahodová
11 shared publications- Mauro Carrara
Medical Physics Unit, Fondazione IRCCS Istituto Nazionale Tumori, Milan, Italy
9 shared publications
Latest Publications
- Open Access
- 1 August 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (8) , 085015
TPC magnetic field sensors for fusion reactors: instrumented neutron irradiation test
Future thermonuclear fusion reactors will impose extreme demands on diagnostic components, particularly regarding radiation hardness, high-temperature tolerance and reliability, with limited or no opportunities for maintenance or replacement. Innovative, thoroughly tested and qualified solutions are crucial to meet these challenges. The exploitation of thick-printed copper (TPC) technology has recently enabled the development of compact and efficient inductive and steady-state magnetic field sensors. TPC coils, with an optimized winding arrangement designed to minimize cross-field sensitivity and reduce temperature gradient-induced spurious voltages, have been extensively tested, including exposure to high neutron fluence during instrumented neutron irradiation tests up to 0.5 dpa at the LVR-15 fission reactor. This contribution will describe these novel design solutions and present the findings of comprehensive testing. Data analysis of resistance measurements including temperature and irradiation models are presented in this paper.
- 1 August 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (8) , 085015
Open AccessTPC magnetic field sensors for fusion reactors: instrumented neutron irradiation test
Future thermonuclear fusion reactors will impose extreme demands on diagnostic components, particularly regarding radiation hardness, high-temperature tolerance and reliability, with limited or no opportunities for maintenance or replacement. Innovative, thoroughly tested and qualified solutions are crucial to meet these challenges. The exploitation of thick-printed copper (TPC) technology has recently enabled the development of compact and efficient inductive and steady-state magnetic field sensors. TPC coils, with an optimized winding arrangement designed to minimize cross-field sensitivity and reduce temperature gradient-induced spurious voltages, have been extensively tested, including exposure to high neutron fluence during instrumented neutron irradiation tests up to 0.5 dpa at the LVR-15 fission reactor. This contribution will describe these novel design solutions and present the findings of comprehensive testing. Data analysis of resistance measurements including temperature and irradiation models are presented in this paper.
- Open Access
- 31 July 2026
- Published by MDPI AG in Preprints.org
Inertia and Frame-Dragging in the Observable Universe
In the time of Galileo and Newton, inertia was understood as a property of absolute space. Later, it was interpreted as a consequence of the gravitational influence of distant matter. Einstein suggested that this influence is related to frame-dragging, a phenomenon arising in general relativity. In this work we pursue this idea by using the frame-dragging components corresponding to Coriolis and linear acceleration. By integrating these contributions over the mass of the entire observable universe, one should obtain a value close to the classical Coriolis or linear inertial acceleration. This provides a quantitative test of Einstein's hypothesis.Within the approximations adopted here, the resulting values are indeed consistent with this hypothesis.
- 31 July 2026
- Published by MDPI AG in Preprints.org
Open AccessInertia and Frame-Dragging in the Observable Universe
In the time of Galileo and Newton, inertia was understood as a property of absolute space. Later, it was interpreted as a consequence of the gravitational influence of distant matter. Einstein suggested that this influence is related to frame-dragging, a phenomenon arising in general relativity. In this work we pursue this idea by using the frame-dragging components corresponding to Coriolis and linear acceleration. By integrating these contributions over the mass of the entire observable universe, one should obtain a value close to the classical Coriolis or linear inertial acceleration. This provides a quantitative test of Einstein's hypothesis.Within the approximations adopted here, the resulting values are indeed consistent with this hypothesis.
- Open Access
- 1 April 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (4) , 045034
Instrumented high fluence neutron irradiation test of antimony Hall sensors
Hall sensors based on antimony sensitive layer will be installed on ITER within the system of outer vessel steady-state magnetic field sensors and they are also considered for deployment on future European demonstration fusion power reactor (EU-DEMO). The role of these sensors will be to contribute to determination of the key tokamak plasma parameters such as the plasma position, shape, and plasma current. This paper presents the design of an instrumented high fluence neutron irradiation experiment, where antimony Hall sensors are exposed to the neutron and gamma radiation of the LVR-15 research reactor core (10 MW thermal). The goal of this experiment is to qualify the antimony Hall sensors for use on the EU-DEMO reactor. Initial results from the first phase of the experiment where the sensors were exposed to the fast neutron fluence ( E > 0.1 MeV) of 1.4 × 10 20 cm −2 are reported.
- 1 April 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (4) , 045034
Open AccessInstrumented high fluence neutron irradiation test of antimony Hall sensors
Hall sensors based on antimony sensitive layer will be installed on ITER within the system of outer vessel steady-state magnetic field sensors and they are also considered for deployment on future European demonstration fusion power reactor (EU-DEMO). The role of these sensors will be to contribute to determination of the key tokamak plasma parameters such as the plasma position, shape, and plasma current. This paper presents the design of an instrumented high fluence neutron irradiation experiment, where antimony Hall sensors are exposed to the neutron and gamma radiation of the LVR-15 research reactor core (10 MW thermal). The goal of this experiment is to qualify the antimony Hall sensors for use on the EU-DEMO reactor. Initial results from the first phase of the experiment where the sensors were exposed to the fast neutron fluence ( E > 0.1 MeV) of 1.4 × 10 20 cm −2 are reported.
- Open Access
- 5 October 2024
- Published by MDPI AG in Journal of Nuclear Engineering
- Vol. 5 (4) , 436-444
Long-Term Afterglow Measurement of Scintillators after Gamma Irradiation
The long-term afterglow of scintillators is an important aspect, especially when the light signal from a scintillator is evaluated in the current mode. Scintillators used for radiation detection exhibit an afterglow, which usually comes from multiple components that have different decay times. A high level of afterglow usually has a negative influence on the detection parameters for the energy resolution in spectrometry measurements or X-ray and neutron imaging. The paper deals with the long-term afterglow of some types of scintillators, which is more significant for integral measurement when the current is measured in a photodetector. The range of decay times studied was in the order of tens of seconds to days. Seven types of scintillators were examined: BGO, CaF2(Eu), CdWO4, CsI(Tl), LiI(Eu), NaI(Tl), and plastic scintillator. The scintillators were excited by gamma-ray radiation. After irradiation, the detection unit, along with the scintillator, was moved to a laboratory where the anode current of the photomultiplier tube was measured using a picoammeter for at least a day. The measurements showed that CdWO4 and plastic scintillators have relatively low long-term afterglow signals in comparison to the other scintillators studied.
- 5 October 2024
- Published by MDPI AG in Journal of Nuclear Engineering
- Vol. 5 (4) , 436-444
Open AccessLong-Term Afterglow Measurement of Scintillators after Gamma Irradiation
The long-term afterglow of scintillators is an important aspect, especially when the light signal from a scintillator is evaluated in the current mode. Scintillators used for radiation detection exhibit an afterglow, which usually comes from multiple components that have different decay times. A high level of afterglow usually has a negative influence on the detection parameters for the energy resolution in spectrometry measurements or X-ray and neutron imaging. The paper deals with the long-term afterglow of some types of scintillators, which is more significant for integral measurement when the current is measured in a photodetector. The range of decay times studied was in the order of tens of seconds to days. Seven types of scintillators were examined: BGO, CaF2(Eu), CdWO4, CsI(Tl), LiI(Eu), NaI(Tl), and plastic scintillator. The scintillators were excited by gamma-ray radiation. After irradiation, the detection unit, along with the scintillator, was moved to a laboratory where the anode current of the photomultiplier tube was measured using a picoammeter for at least a day. The measurements showed that CdWO4 and plastic scintillators have relatively low long-term afterglow signals in comparison to the other scintillators studied.
- Open Access
- 24 November 2023
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (4) , 1250-1253
Long term activity measurement of the primary circuit water on the LVR-15 research reactor
- 24 November 2023
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (4) , 1250-1253
Open AccessLong term activity measurement of the primary circuit water on the LVR-15 research reactor
- 22 August 2022
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 198 (9-11) , 666-669
LONG-TERM AFTERGLOW OF SOLID SCINTILLATORS
Most of scintillators used for radiation detection exhibit afterglow, which is emission of light with longer decay times than that of main light pulse. High signal from afterglow has usually negative influence on detection parameters, e.g. for energy resolution in spectrometry measurements. The paper deals with long-term afterglow of some types of scintillators, which is more significant in the case of integral measurement when current in the photodetector is measured. The range of studied decay times was in the order of tens of seconds to days. Seven types of scintillators were measured: BGO, CaF2(Eu), CdWO4, CsI(Tl), LiI(Eu), NaI(Tl) and plastic scintillator. Excitation of scintillators was made using a UV lamp. After UV irradiation, a scintillator was inserted to scintillation detection unit and the anode current of photomultiplier tube was measured with a picoammeter. As results, CaF2(Eu) and plastic scintillator have relatively low long-term afterglow signal compared with other measured scintillators.
- 22 August 2022
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 198 (9-11) , 666-669
LONG-TERM AFTERGLOW OF SOLID SCINTILLATORS
Most of scintillators used for radiation detection exhibit afterglow, which is emission of light with longer decay times than that of main light pulse. High signal from afterglow has usually negative influence on detection parameters, e.g. for energy resolution in spectrometry measurements. The paper deals with long-term afterglow of some types of scintillators, which is more significant in the case of integral measurement when current in the photodetector is measured. The range of studied decay times was in the order of tens of seconds to days. Seven types of scintillators were measured: BGO, CaF2(Eu), CdWO4, CsI(Tl), LiI(Eu), NaI(Tl) and plastic scintillator. Excitation of scintillators was made using a UV lamp. After UV irradiation, a scintillator was inserted to scintillation detection unit and the anode current of photomultiplier tube was measured with a picoammeter. As results, CaF2(Eu) and plastic scintillator have relatively low long-term afterglow signal compared with other measured scintillators.
- Open Access
- 1 January 2022
- Published by RAD Centre
Afterglow study of solid scintillators excited by gamma radiation
- 1 January 2022
- Published by RAD Centre
Open AccessAfterglow study of solid scintillators excited by gamma radiation
- 16 November 2020
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 7 (2)
Detection of Neutrons Emitted From Reactor Primary Circuit Water by Discontinuing Flow Method
On-line activity measurement of fission products in a primary circuit water is often used for a fuel failure detection in research and power nuclear reactors. When gamma spectrometry is used for the activity measurement, high signal from 16N radionuclide and other activation products make the detection of fission products difficult. The detection of delayed neutrons emitted from several fission products is also used; however, if the detector is placed near the outlet coolant pipe, the signal from the delayed neutrons cannot be distinguished from the neutrons emitted due to 17N decay and deuterium photofission, with exception of a reactor scram condition. In this paper, a method of discontinuing the flow of primary circuit water is described. This method is based on the water flowing through a bypass on the outlet pipe to the sampling container and the flow is periodically temporarily interrupted, e.g., using 200 s + 200 s cycles. Neutrons located in the vicinity of the sampling container are continuously detected with a measuring sampling time of less than 2 s. The signal part, corresponding to the delayed neutrons, is evaluated by the signal decay analyzing during the flow interruption. The main sources of delayed neutrons suitable for this method are 137I, 87Br, and 88Br radionuclides with half-lives of 24.5 s, 55.7 s, and 16.5 s, respectively. The method was theoretically analyzed and experimentally verified in the LVR-15 research reactor.
- 16 November 2020
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 7 (2)
Detection of Neutrons Emitted From Reactor Primary Circuit Water by Discontinuing Flow Method
On-line activity measurement of fission products in a primary circuit water is often used for a fuel failure detection in research and power nuclear reactors. When gamma spectrometry is used for the activity measurement, high signal from 16N radionuclide and other activation products make the detection of fission products difficult. The detection of delayed neutrons emitted from several fission products is also used; however, if the detector is placed near the outlet coolant pipe, the signal from the delayed neutrons cannot be distinguished from the neutrons emitted due to 17N decay and deuterium photofission, with exception of a reactor scram condition. In this paper, a method of discontinuing the flow of primary circuit water is described. This method is based on the water flowing through a bypass on the outlet pipe to the sampling container and the flow is periodically temporarily interrupted, e.g., using 200 s + 200 s cycles. Neutrons located in the vicinity of the sampling container are continuously detected with a measuring sampling time of less than 2 s. The signal part, corresponding to the delayed neutrons, is evaluated by the signal decay analyzing during the flow interruption. The main sources of delayed neutrons suitable for this method are 137I, 87Br, and 88Br radionuclides with half-lives of 24.5 s, 55.7 s, and 16.5 s, respectively. The method was theoretically analyzed and experimentally verified in the LVR-15 research reactor.
- Open Access
- 1 September 2020
- Published by Elsevier in Radiation Measurements
- Vol. 137
REFLECT – Research flight of EURADOS and CRREAT: Intercomparison of various radiation dosimeters onboard aircraft
- 1 September 2020
- Published by Elsevier in Radiation Measurements
- Vol. 137
Open AccessREFLECT – Research flight of EURADOS and CRREAT: Intercomparison of various radiation dosimeters onboard aircraft
- 12 August 2020
- Published by American Physical Society (APS) in Physical Review C
- Vol. 102 (2) , 024613
Neutron capture cross section of from irradiation with cold and reactor neutronsThe neutron capture cross section of was measured with cold and reactor neutrons by the activation method, relative to the well-known cross section of . Three targets containing a total of atoms in the form of chloride salt were prepared using a stock solution obtained from activated accelerator waste in the course of the ERAWAST initiative at Paul Scherrer Institute, Switzerland (PSI). Natural cobalt salt was added to the sample material as an internal neutron flux monitor. The total numbers of and atoms in the target were deduced via mass spectrometric measurements at PSI. Cold-neutron activation was carried out at the ICON beamline at PSI. Reactor activation was performed at the LVR-15 research reactor of Research Centre Řež in a well-moderated neutron field of an outer reactor channel. The thermal-neutron capture cross section and the resonance integral were determined by the cadmium ratio method. The induced activities of and were quantified by high-resolution -ray spectrometry. The obtained thermal-neutron capture cross section of agrees well with previously reported results. The uncertainty of this value could be reduced by almost an order of magnitude with respect to older measurements and is on a level comparable to stable nuclides. The resonance integral of was obtained for the real reactor spectrum with epithermal-spectrum shape factor .- 12 August 2020
- Published by American Physical Society (APS) in Physical Review C
- Vol. 102 (2) , 024613
Neutron capture cross section of from irradiation with cold and reactor neutronsThe neutron capture cross section of was measured with cold and reactor neutrons by the activation method, relative to the well-known cross section of . Three targets containing a total of atoms in the form of chloride salt were prepared using a stock solution obtained from activated accelerator waste in the course of the ERAWAST initiative at Paul Scherrer Institute, Switzerland (PSI). Natural cobalt salt was added to the sample material as an internal neutron flux monitor. The total numbers of and atoms in the target were deduced via mass spectrometric measurements at PSI. Cold-neutron activation was carried out at the ICON beamline at PSI. Reactor activation was performed at the LVR-15 research reactor of Research Centre Řež in a well-moderated neutron field of an outer reactor channel. The thermal-neutron capture cross section and the resonance integral were determined by the cadmium ratio method. The induced activities of and were quantified by high-resolution -ray spectrometry. The obtained thermal-neutron capture cross section of agrees well with previously reported results. The uncertainty of this value could be reduced by almost an order of magnitude with respect to older measurements and is on a level comparable to stable nuclides. The resonance integral of was obtained for the real reactor spectrum with epithermal-spectrum shape factor .