Single-step nonlinear diffusion tensor estimation in the presence of microscopic and macroscopic motion
Open Access
- 21 April 2008
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 59 (5) , 1138-1150
Abstract
Patient motion can cause serious artifacts in diffusion tensor imaging (DTI), diminishing the reliability of the estimated diffusion tensor information. Studies in this field have so far been limited mainly to the correction of miniscule physiological motion. In order to correct for gross patient motion it is not sufficient to correct for misregistration between successive shots; the change in the diffusion‐encoding direction must also be accounted for. This becomes particularly important for multishot sequences, whereby—in the presence of motion—each shot is encoded with a different diffusion weighting. In this study a general mathematical framework to correct for gross patient motion present in a multishot and multicoil DTI scan is presented. A signal model is presented that includes the effect of rotational and translational motion in the patient frame of reference. This model was used to create a nonlinear least‐squares formulation, from which the diffusion tensors were obtained using a nonlinear conjugate gradient algorithm. Applications to both phantom simulations and in vivo studies showed that in the case of gross motion the proposed algorithm performs superiorly compared to conventional methods used for tensor estimation. Magn Reson Med 59:1138–1150, 2008.Keywords
This publication has 30 references indexed in Scilit:
- Origin and minimization of residual motion‐related artifacts in navigator‐corrected segmented diffusion‐weighted EPI of the human brainMagnetic Resonance in Medicine, 2002
- Improved diffusion‐weighted single‐shot echo‐planar imaging (EPI) in stroke using sensitivity encoding (SENSE)Magnetic Resonance in Medicine, 2001
- Implications of bulk motion for diffusion‐weighted imaging experiments: Effects, mechanisms, and solutionsJournal of Magnetic Resonance Imaging, 2001
- Diffusion-weighted Imaging with Navigated Interleaved Echo-planar Imaging and a Conventional Gradient SystemRadiology, 1999
- Diffusion tensor MR imaging of the human brain.Radiology, 1996
- Analysis and comparison of motion‐correction techniques in diffusion‐weighted imagingJournal of Magnetic Resonance Imaging, 1996
- Analysis and correction of motion artifacts in diffusion weighted imagingMagnetic Resonance in Medicine, 1994
- Estimation of the Effective Self-Diffusion Tensor from the NMR Spin EchoJournal of Magnetic Resonance, Series B, 1994
- Effect of bulk tissue motion on quantitative perfusion and diffusion magnetic resonance imagingMagnetic Resonance in Medicine, 1991
- Early detection of regional cerebral ischemia in cats: Comparison of diffusion‐ and T2‐weighted MRI and spectroscopyMagnetic Resonance in Medicine, 1990