A Study on the Impact of Pulse Shaping Parameters on Zero-Crossing Method Performance for Neutron/Gamma Discrimination
- 10 October 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (11) , 2464-2470
Abstract
This work examines the relationship between the pulse shaping time parameters, namely the integral and differential constants, and the ability of the zero-crossing (ZC) method to perform the neutron/gamma pulse shaping discrimination (PSD). To mitigate the impact of various noise sources, such as the preamplifier, we developed a simulation model with adjustable shaping time parameters and applied it to evaluate the effects of shaping time parameters on neutron/gamma discrimination capability. Experimental radiation pulses were collected using a system comprised of an EJ-301 scintillator detector coupled with a Hamamatsu R9420 photomultiplier and a DRS4 digitizer, along with 252 Cf, 60 Co, 137 Cs radioactive sources. In total, we have surveyed multiple quality factors of the ZC method, namely the figure of merit (FoM), discriminant quality function (F(u)), and misidentification ratio, as a function of integral and differential time constants ranging from 1 to 160 ns. The results indicate that the ZC method provides optimal quality for the EJ-301 scintillator detector when the differential and integral constants are set within the ranges of 80 to 100 ns and 40 to 80 ns, respectively. Additionally, the relationships between various PSD quality factors and the pulse shaping parameters vary. Consequently, it is necessary to simultaneously examine multiple PSD quality factors concerning pulse shaping parameters to determine their optimal values.Keywords
Funding Information
- Ministry of Education and Training of Vietnam (B2022-DLA-02)
This publication has 15 references indexed in Scilit:
- Digital pulse shape discrimination methods for n-γ separation in an EJ-301 liquid scintillation detectorChinese Physics C, 2015
- Digital two-parametric processing of the output data from radiation detectorsProgress in Nuclear Science and Technology, 2014
- Influence of sampling properties of fast-waveform digitizers on neutron−gamma-ray, pulse-shape discrimination for organic scintillation detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2013
- Application of the DRS chip for fast waveform digitizingNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2010
- Application of digital zero-crossing technique for neutron–gamma discrimination in liquid organic scintillation detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2010
- A compact pulse shape discriminator module for large neutron detector arraysNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2008
- Development of a handheld device for simultaneous monitoring of fast neutrons and gamma raysIEEE Transactions on Nuclear Science, 2002
- Pulse shape analysis of liquid scintillators for neutron studiesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2002
- Pulse shape discrimination in inorganic and organic scintillators. INuclear Instruments and Methods, 1971
- Pulse shape discriminationNuclear Instruments and Methods, 1964