Nguyen Xuan Hai
Research Subjects
Research Interests
Nguyen Xuan Hai has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Nguyen Ngoc Anh
Phenikaa University
9 shared publications - Duong Thanh Tai
Department of Medical Physics Faculty of Medicine Nguyen Tat Thanh University Ho Chi Minh City Vietnam
4 shared publications - David Andrew Bradley
Centre for Applied Physics and Radiation Technologies, School of Engineering and Technology, Sunway University, Petaling Jaya 47500, Selangor, Malaysia
3 shared publications - Dinh Tien Hung
Military Institute of Chemical and Environmental Engineering (MICEE), Hanoi, Vietnam
3 shared publications - James Chun Lam Chow
Radiation Medicine Program, Princess Margaret Cancer Centre, University Health Network, Toronto, ON M5G 1X6, Canada
3 shared publications - Nguyen Quang Hung
Duy Tan University
3 shared publications
Latest Publications
- 25 September 2026
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 300
Temporal variation of indoor 222Rn concentrations under contrasting room-opening conditions: A case study in Da Lat, Vietnam
- 25 September 2026
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 300
Temporal variation of indoor 222Rn concentrations under contrasting room-opening conditions: A case study in Da Lat, Vietnam
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (3) , 497-504
End-to-End Geant4 Waveform Modeling and Geometry Selection of EJ-276/SiPM Detectors for Neutron-Gamma Discrimination
An end-to-end simulation and experimental validation framework is presented for compact neutron detectors based on EJ-276 plastic scintillators coupled to silicon photomultipliers. The workflow combines Geant4 optical-photon transport with a physics-based signal-formation model to predict preamplifier-level voltage waveforms. Benchmarking with a cobalt-60 source demonstrates close waveform agreement after baseline subtraction and peak-time alignment, with high similarity over 100-500 ns (correlation r = 0.997 and normalized root mean square error nRMSE= 2.8%). The model preserves key pulse observables, including peak amplitude (0.5% difference), peak timing (about 1 ns), and pulse integral (0.34% difference), while the residual mismatch is mainly confined to fast/tail dynamics (slightly faster rise and a shorter effective decay constant in simulation). The validated model is then applied to eight geometries to quantify trade-offs between neutron detection efficiency and neutron–gamma separation. Using figure of merit, intrinsic detection efficiency, and misclassification rate, we identify that designs near Ø50 mm × 50 mm balance discrimination and efficiency for compact, field-deployable instruments. The proposed approach enables predictive optimization of pulse-shape discrimination capable plastic-scintillator detectors without iterative prototyping, and is readily extensible to other silicon photomultipliers based systems.
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (3) , 497-504
End-to-End Geant4 Waveform Modeling and Geometry Selection of EJ-276/SiPM Detectors for Neutron-Gamma Discrimination
An end-to-end simulation and experimental validation framework is presented for compact neutron detectors based on EJ-276 plastic scintillators coupled to silicon photomultipliers. The workflow combines Geant4 optical-photon transport with a physics-based signal-formation model to predict preamplifier-level voltage waveforms. Benchmarking with a cobalt-60 source demonstrates close waveform agreement after baseline subtraction and peak-time alignment, with high similarity over 100-500 ns (correlation r = 0.997 and normalized root mean square error nRMSE= 2.8%). The model preserves key pulse observables, including peak amplitude (0.5% difference), peak timing (about 1 ns), and pulse integral (0.34% difference), while the residual mismatch is mainly confined to fast/tail dynamics (slightly faster rise and a shorter effective decay constant in simulation). The validated model is then applied to eight geometries to quantify trade-offs between neutron detection efficiency and neutron–gamma separation. Using figure of merit, intrinsic detection efficiency, and misclassification rate, we identify that designs near Ø50 mm × 50 mm balance discrimination and efficiency for compact, field-deployable instruments. The proposed approach enables predictive optimization of pulse-shape discrimination capable plastic-scintillator detectors without iterative prototyping, and is readily extensible to other silicon photomultipliers based systems.
- Open Access
- 6 May 2025
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 236
Impact of radiobiological parameters on tumor control probability in rectal cancer using the Poisson linear quadratic model
- 6 May 2025
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 236
Open AccessImpact of radiobiological parameters on tumor control probability in rectal cancer using the Poisson linear quadratic model
- Open Access
- 23 April 2025
- Published by Oxford University Press (OUP) in Japanese Journal of Clinical Oncology
- Vol. 55 (8) , 925-932
Enhancing patient positioning accuracy: evaluating daily cone beam computed tomography in the halcyon system
Background: Precise patient positioning is crucial for successful radiotherapy, ensuring accurate delivery of radiation to tumors while minimizing exposure to healthy tissues. Positional errors can significantly impact treatment efficacy and increase side effects. This study evaluates the effectiveness of daily cone beam computed tomography (CBCT) imaging in the Halcyon system for detecting and correcting patient misalignments across various cancer types and treatment sites. Methods: A retrospective analysis was conducted on 411 patients treated with the Varian Halcyon linear accelerator from August 2022 to August 2024. Patients were grouped based on tumor location: Head and Neck (118 patients), Chest (188 patients), and Pelvis (105 patients). Daily pre-treatment CBCT scans were performed to verify positioning, with shifts in the x, y, and z axes quantified and adjusted using automated couch corrections. Results: The study revealed average positional shifts along the x-axis of ~0.112 cm, while both the Chest and Pelvic groups recorded 0.194 cm. The y-axis deviations were 0.135 cm for Head and Neck, 0.206 cm for Chest, and 0.195 cm for the Pelvis. On the z-axis, a mean deviation of 0.07 cm was found for the Head and Neck group, while 0.11 cm for the Chest group, and 0.085 cm for the Pelvic group. The Head and Neck group exhibited the smallest standard deviations across all axes, indicating greater positional consistency. Normalized density distributions showed distinct emergent patterns, the Head and Neck group showing tighter distributions compared to the broader distributions observed in the Chest and Pelvic groups. Conclusions: Daily CBCT imaging in the Halcyon system significantly enhances patient positioning accuracy in radiotherapy. The findings demonstrate that this approach minimizes positional shifts, particularly in the Head and Neck region, essential for optimizing treatment outcomes and reducing the risk of adverse effects. Future studies should further explore the integration of advanced imaging techniques to improve precision in patient positioning.
- 23 April 2025
- Published by Oxford University Press (OUP) in Japanese Journal of Clinical Oncology
- Vol. 55 (8) , 925-932
Open AccessEnhancing patient positioning accuracy: evaluating daily cone beam computed tomography in the halcyon system
Background: Precise patient positioning is crucial for successful radiotherapy, ensuring accurate delivery of radiation to tumors while minimizing exposure to healthy tissues. Positional errors can significantly impact treatment efficacy and increase side effects. This study evaluates the effectiveness of daily cone beam computed tomography (CBCT) imaging in the Halcyon system for detecting and correcting patient misalignments across various cancer types and treatment sites. Methods: A retrospective analysis was conducted on 411 patients treated with the Varian Halcyon linear accelerator from August 2022 to August 2024. Patients were grouped based on tumor location: Head and Neck (118 patients), Chest (188 patients), and Pelvis (105 patients). Daily pre-treatment CBCT scans were performed to verify positioning, with shifts in the x, y, and z axes quantified and adjusted using automated couch corrections. Results: The study revealed average positional shifts along the x-axis of ~0.112 cm, while both the Chest and Pelvic groups recorded 0.194 cm. The y-axis deviations were 0.135 cm for Head and Neck, 0.206 cm for Chest, and 0.195 cm for the Pelvis. On the z-axis, a mean deviation of 0.07 cm was found for the Head and Neck group, while 0.11 cm for the Chest group, and 0.085 cm for the Pelvic group. The Head and Neck group exhibited the smallest standard deviations across all axes, indicating greater positional consistency. Normalized density distributions showed distinct emergent patterns, the Head and Neck group showing tighter distributions compared to the broader distributions observed in the Chest and Pelvic groups. Conclusions: Daily CBCT imaging in the Halcyon system significantly enhances patient positioning accuracy in radiotherapy. The findings demonstrate that this approach minimizes positional shifts, particularly in the Head and Neck region, essential for optimizing treatment outcomes and reducing the risk of adverse effects. Future studies should further explore the integration of advanced imaging techniques to improve precision in patient positioning.
- 1 July 2024
- Published by Taylor & Francis in Nuclear Science and Engineering
- Vol. 199 (2) , 314-324
Examining Beam Matching in the Commissioning of a Halcyon Accelerator
- 1 July 2024
- Published by Taylor & Francis in Nuclear Science and Engineering
- Vol. 199 (2) , 314-324
Examining Beam Matching in the Commissioning of a Halcyon Accelerator
- 10 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (11) , 2464-2470
A Study on the Impact of Pulse Shaping Parameters on Zero-Crossing Method Performance for Neutron/Gamma Discrimination
This work examines the relationship between the pulse shaping time parameters, namely the integral and differential constants, and the ability of the zero-crossing (ZC) method to perform the neutron/gamma pulse shaping discrimination (PSD). To mitigate the impact of various noise sources, such as the preamplifier, we developed a simulation model with adjustable shaping time parameters and applied it to evaluate the effects of shaping time parameters on neutron/gamma discrimination capability. Experimental radiation pulses were collected using a system comprised of an EJ-301 scintillator detector coupled with a Hamamatsu R9420 photomultiplier and a DRS4 digitizer, along with 252 Cf, 60 Co, 137 Cs radioactive sources. In total, we have surveyed multiple quality factors of the ZC method, namely the figure of merit (FoM), discriminant quality function (F(u)), and misidentification ratio, as a function of integral and differential time constants ranging from 1 to 160 ns. The results indicate that the ZC method provides optimal quality for the EJ-301 scintillator detector when the differential and integral constants are set within the ranges of 80 to 100 ns and 40 to 80 ns, respectively. Additionally, the relationships between various PSD quality factors and the pulse shaping parameters vary. Consequently, it is necessary to simultaneously examine multiple PSD quality factors concerning pulse shaping parameters to determine their optimal values.
- 10 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (11) , 2464-2470
A Study on the Impact of Pulse Shaping Parameters on Zero-Crossing Method Performance for Neutron/Gamma Discrimination
This work examines the relationship between the pulse shaping time parameters, namely the integral and differential constants, and the ability of the zero-crossing (ZC) method to perform the neutron/gamma pulse shaping discrimination (PSD). To mitigate the impact of various noise sources, such as the preamplifier, we developed a simulation model with adjustable shaping time parameters and applied it to evaluate the effects of shaping time parameters on neutron/gamma discrimination capability. Experimental radiation pulses were collected using a system comprised of an EJ-301 scintillator detector coupled with a Hamamatsu R9420 photomultiplier and a DRS4 digitizer, along with 252 Cf, 60 Co, 137 Cs radioactive sources. In total, we have surveyed multiple quality factors of the ZC method, namely the figure of merit (FoM), discriminant quality function (F(u)), and misidentification ratio, as a function of integral and differential time constants ranging from 1 to 160 ns. The results indicate that the ZC method provides optimal quality for the EJ-301 scintillator detector when the differential and integral constants are set within the ranges of 80 to 100 ns and 40 to 80 ns, respectively. Additionally, the relationships between various PSD quality factors and the pulse shaping parameters vary. Consequently, it is necessary to simultaneously examine multiple PSD quality factors concerning pulse shaping parameters to determine their optimal values.
- 11 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (6) , 1203-1211
Nuclide Identification Algorithm for the Large-Size Plastic Detectors Based on Artificial Neural Network
This article proposes a multi-label classification model using an artificial neural network (ANN) to identify both an individual and a mixture of radionuclides in gamma spectra obtained from a $250\times 250\times 50$ -mm 3 EJ-200 plastic scintillation detector. This model is evaluated under the scenario applied to pedestrian radiation portal monitors (RPMs) to judge how well it works in practice. The simulated and measured gamma of 241 Am, 133 Ba, 137 Cs, 60 Co, 152 Eu, and $^{131}\text{I}$ radioactive sources and background are used to generate the training dataset. Measurement data with varying source-to-detector distances, shielding thicknesses, and incidence angles are also taken into account. The experimental results show that the mean value of the accuracy can be achieved at about 98.8% and 94.9% for single- and multi-isotope identification, respectively. In addition, the model can well precisely recognize radionuclides in the gamma spectrum whose gain shift is up to 10%. The dependence of the true positive (TP) rate on the count quality factors of individual radionuclides, which was defined as the ratio between the net count rate and its associated uncertainty, is examined. The detection sensitivities, defined as the minimum count quality factor to obtain a TP rate of 95%, for 241 Am, 133 Ba, 137 Cs, 60 Co, 152 Eu, and $^{131}\text{I}$ are 8.90, 11.86, 8.96, 8.21, 12.54, and 11.89, respectively. With such encouraging results, the proposed model should be a useful technique for radionuclide recognition.
- 11 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (6) , 1203-1211
Nuclide Identification Algorithm for the Large-Size Plastic Detectors Based on Artificial Neural Network
This article proposes a multi-label classification model using an artificial neural network (ANN) to identify both an individual and a mixture of radionuclides in gamma spectra obtained from a $250\times 250\times 50$ -mm 3 EJ-200 plastic scintillation detector. This model is evaluated under the scenario applied to pedestrian radiation portal monitors (RPMs) to judge how well it works in practice. The simulated and measured gamma of 241 Am, 133 Ba, 137 Cs, 60 Co, 152 Eu, and $^{131}\text{I}$ radioactive sources and background are used to generate the training dataset. Measurement data with varying source-to-detector distances, shielding thicknesses, and incidence angles are also taken into account. The experimental results show that the mean value of the accuracy can be achieved at about 98.8% and 94.9% for single- and multi-isotope identification, respectively. In addition, the model can well precisely recognize radionuclides in the gamma spectrum whose gain shift is up to 10%. The dependence of the true positive (TP) rate on the count quality factors of individual radionuclides, which was defined as the ratio between the net count rate and its associated uncertainty, is examined. The detection sensitivities, defined as the minimum count quality factor to obtain a TP rate of 95%, for 241 Am, 133 Ba, 137 Cs, 60 Co, 152 Eu, and $^{131}\text{I}$ are 8.90, 11.86, 8.96, 8.21, 12.54, and 11.89, respectively. With such encouraging results, the proposed model should be a useful technique for radionuclide recognition.
- 11 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-11
A Composite Method for Improving the Pulse Shape Discrimination Efficiency of a Scintillation Detector Using EJ-301 Liquid
This article presents a composite (COM) method to obtain the high-resolution pulse shape discrimination (PSD) for the neutron and gamma-ray pulses generated from scintillation detectors. The method, which is based on a selective combination of the digital charge integration (DCI) with the reference pulse method, aims to reduce the mixed radiation events in the low-energy range. An EJ-301 liquid scintillation detector together with a fast sampling analog-to-digital converter (ADC) is used to measure and digitize the pulses induced from the radioactive decays of 60 Co and 252 Cf, which are then analyzed by our COM method. The proposed method is evaluated using the figure of merit (FoM) and separation quality function $F(u)$ , and the results are compared with three known methods, namely the DCI, standard event fit (SEF), and artificial neural network (ANN) methods. We show that the average values of FoM and $F(u)$ obtained within the COM method are about ten times higher than those obtained within the DCI and SEF in the whole energy range from 50 to 1000 keV electron equivalent (keVee). In particular, by using the COM method, the percentage of gamma events being confused as neutrons ranges from 0.32% to 8.80% when the energy is reduced from 400 to 50 keVee. This finding, which is significantly lower than those obtained by using the DCI and SEF, indicates that the proposed COM method should be considered as a leading method for producing a neutron/gamma PSD counter system with high resolution.
- 11 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-11
A Composite Method for Improving the Pulse Shape Discrimination Efficiency of a Scintillation Detector Using EJ-301 Liquid
This article presents a composite (COM) method to obtain the high-resolution pulse shape discrimination (PSD) for the neutron and gamma-ray pulses generated from scintillation detectors. The method, which is based on a selective combination of the digital charge integration (DCI) with the reference pulse method, aims to reduce the mixed radiation events in the low-energy range. An EJ-301 liquid scintillation detector together with a fast sampling analog-to-digital converter (ADC) is used to measure and digitize the pulses induced from the radioactive decays of 60 Co and 252 Cf, which are then analyzed by our COM method. The proposed method is evaluated using the figure of merit (FoM) and separation quality function $F(u)$ , and the results are compared with three known methods, namely the DCI, standard event fit (SEF), and artificial neural network (ANN) methods. We show that the average values of FoM and $F(u)$ obtained within the COM method are about ten times higher than those obtained within the DCI and SEF in the whole energy range from 50 to 1000 keV electron equivalent (keVee). In particular, by using the COM method, the percentage of gamma events being confused as neutrons ranges from 0.32% to 8.80% when the energy is reduced from 400 to 50 keVee. This finding, which is significantly lower than those obtained by using the DCI and SEF, indicates that the proposed COM method should be considered as a leading method for producing a neutron/gamma PSD counter system with high resolution.
- 1 March 2021
- Published by Elsevier in Nuclear Physics A
- Vol. 1007
Level scheme of 164Dy obtained from 163Dy(n,2γ) experiment- 1 March 2021
- Published by Elsevier in Nuclear Physics A
- Vol. 1007
Level scheme of 164Dy obtained from 163Dy(n,2γ) experiment