Surface and Thermal Characteristics of Single-Use Electrosurgical Pencils After Clinical Reuse and In-Hospital Reprocessing
- 20 October 2017
- journal article
- Published by ASME International in Journal of Medical Devices
- Vol. 11 (4) , 041010
Abstract
Safety and efficacy issues are associated with reprocessing of single-use electrosurgical pencils (EPs), requiring methods for assessing the reprocessing protocol before clinical reuse. This study aimed at monitoring the surface characteristics of single-use EPs subjected to multiple clinical use and in-hospital reprocessing. A total of 24 single-use-labeled EPs were divided in five test groups and one control group. The test groups were subjected to a different number of clinical uses, ranging from one to five. A multitechnique approach based on optical stereomicroscopy (OM), scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDXS), differential scanning calorimetry (DSC), and thermogravimetric analysis (TGA) was applied. The silicon coating of the tip was significantly reduced, and foreign bodies were occasionally found on reprocessed EPs. The amount of biological debris and chemical residuals increased with the number of reprocessing cycles in critical areas. The degradation temperature of the EP handle polymer showed a progressive significant reduction. Cable cord showed no modification after reprocessing. EP tip could undergo major surface modifications that can affect functionality. The efficacy of the reprocessing protocol in removing debris from the EP handle should be carefully assessed. Surface and thermal characteristics have to be considered for validating a reprocessing protocol of single-use labeled EP.Keywords
This publication has 21 references indexed in Scilit:
- TG–MS analysis of nitrile butadiene rubber blends (NBR/PVC)Journal of Analytical and Applied Pyrolysis, 2011
- What is the use? An international look at reuse of single-use medical devicesInternational Journal of Hygiene and Environmental Health, 2010
- Reuse and Recycling Practices in a Colombian HospitalAORN Journal, 2007
- Different experimental protocols for decontamination affect the cleaning of medical devices. A preliminary electron microscopy analysisJournal of Hospital Infection, 2007
- Comparison of mechanical and in vivo performance of new and reprocessed harmonic scalpelsUrology, 2006
- Electrosurgery: History, Principles, and Current and Future UsesJournal of the American College of Surgeons, 2006
- Functional properties and performance of new and reprocessed coronary angioplasty balloon cathetersJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2006
- Recommended Practices for ElectrosurgeryAORN Journal, 2005
- Evaluation and quantification of reprocessing modification in single-use devices in interventional cardiologyApplied Surface Science, 2004
- Catheter Ablation in a Less Privileged Country: The Importance of Spreading the GoodsPacing and Clinical Electrophysiology, 1995