STSebastian Torres-Montoya

Sebastian Torres-Montoya

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sebastian Torres-Montoya has a total of 99 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Microfluidic Control of Dorsal-Ventral Patterning Within a Single Forebrain Organoid

    by Sebastian Torres-Montoya, Samira Vera-Choqqueccota, Spencer T. Seiler, David Haussler, Sofie R. Salama, Mohammed A. Mostajo-Radji, Mircea Teodorescu

    How distinct regional identities emerge within a single developing brain remains poorly understood. Current in vitro models address this by fusing independently generated organoids, but this introduces variability in size, maturation state, and connectivity, confounding the study of regionalization itself. Here, we present a microfluidic platform that supports the co-development of different tissue identities within a single, continuous 3D culture domain. The device integrates controlled microfluidic flow with real-time fluorescence imaging, providing stable perfusion and high-resolution tracking of molecular transport without the need for embedded sensors or disruptive sampling. By delivering SAG, a Sonic hedgehog pathway agonist, to one surface of mouse forebrain organoids, we induced spatially segregated ventral (Nkx2.1 + ) and dorsal (Pax6 + ) domains within a unified tissue architecture. Controlled morphogen delivery is sufficient to drive region-specific fate specification without organoid fusion, offering a practical, scalable alternative for studying tissue regionalization in vitro .

  • Open Access

    A feedback-driven brain organoid platform enables automated maintenance and high-resolution neural activity monitoring

    by Kateryna Voitiuk, Spencer T. Seiler, Mirella Pessoa de Melo, Jinghui Geng, Tjitse van der Molen, Sebastian Hernandez, Hunter E. Schweiger, Jess L. Sevetson, David F. Parks, Ash Robbins, et al.


  • Open Access

    A feedback-driven brain organoid platform enables automated maintenance and high-resolution neural activity monitoring

    by Kateryna Voitiuk, Spencer T. Seiler, Mirella Pessoa de Melo, Jinghui Geng, Sebastian Hernandez, Hunter E. Schweiger, Jess L. Sevetson, David F. Parks, Ash Robbins, Sebastian Torres-Montoya, et al.

    The analysis of tissue cultures, particularly brain organoids, requires a sophisticated integration and coordination of multiple technologies for monitoring and measuring. We have developed an automated research platform enabling independent devices to achieve collaborative objectives for feedback-driven cell culture studies. Our approach enables continuous, communicative, non-invasive interactions within an Internet of Things (IoT) architecture among various sensing and actuation devices, achieving precisely timed control of in vitro biological experiments. The framework integrates microfluidics, electrophysiology, and imaging devices to maintain cerebral cortex organoids while measuring their neuronal activity. The organoids are cultured in custom, 3D-printed chambers affixed to commercial microelectrode arrays. Periodic feeding is achieved using programmable microfluidic pumps. We developed a computer vision fluid volume estimator used as feedback to rectify deviations in microfluidic perfusion during media feeding/aspiration cycles. We validated the system with a set of 7-day studies of mouse cerebral cortex organoids, comparing manual and automated protocols. The automated protocols were validated in maintaining robust neural activity throughout the experiment. The automated system enabled hourly electrophysiology recordings for the 7-day studies. Median neural unit firing rates increased for every sample and dynamic patterns of organoid firing rates were revealed by high-frequency recordings. Surprisingly, feeding did not affect firing rate. Furthermore, performing media exchange during a recording showed no acute effects on firing rate, enabling the use of this automated platform for reagent screening studies.


  • Open Access

    Cloud-controlled microscopy enables remote project-based biology education in underserved Latinx communities

    by Pierre V. Baudin, Raina E. Sacksteder, Atesh K. Worthington, Kateryna Voitiuk, Victoria T. Ly, Ryan N. Hoffman, Matthew A.T. Elliott, David F. Parks, Rebecca Ward, Sebastian Torres-Montoya, et al.


  • Open Access

    Cloud-controlled microscopy enables remote project-based biology education in Latinx communities in the United States and Latin America

    by Pierre V. Baudin, Raina E. Sacksteder, Atesh K. Worthington, Kateryna Voitiuk, Victoria T. Ly, Ryan N. Hoffman, Matthew A.T. Elliott, David F. Parks, Rebecca Ward, Sebastian Torres-Montoya, et al.

    Project-based learning (PBL) has long been recognized as an effective way to teach complex biology concepts. However, not all institutions have the resources to facilitate effective project-based coursework for students. We have developed a framework for facilitating PBL using remote-controlled internet-connected microscopes. Through this approach, one lab facility can host an experiment allowing simultaneous interaction by many students worldwide. Experiments on this platform can be run on long timescales and with materials that are typically unavailable to high school classrooms. This allows students to perform novel research projects rather than just repeat standard classroom experiments. To investigate the impact of this program, we designed and ran six user studies with students worldwide. All experiments were executed in Santa Cruz and San Francisco, California, with observations and decisions made remotely by the students using their personal computers and cellphones. In surveys gathered after the experiments’ conclusion, students reported increased excitement for science and a greater desire to pursue a career in STEM. This framework represents a novel, scalable, and effective PBL approach that has the potential to democratize biology and STEM education around the world.


  • Open Access

    Anatomical Engineering and 3D Printing for Surgery and Medical Devices: International Review and Future Exponential Innovations

    by José Cornejo, Jorge A. Cornejo-Aguilar, Mariela Vargas, Carlos G. Helguero, Rafhael Milanezi de Andrade, Sebastian Torres-Montoya, Javier Asensio-Salazar, Alvaro Rivero Calle, Jaime Martínez Santos, Aaron Damon, et al.

    Three‐dimensional printing (3DP) has recently gained importance in the medical industry, especially in surgical specialties. It uses different techniques and materials based on patients’ needs, which allows bioprofessionals to design and develop unique pieces using medical imaging provided by computed tomography (CT) and magnetic resonance imaging (MRI). Therefore, the Department of Biology and Medicine and the Department of Physics and Engineering, at the Bioastronautics and Space Mechatronics Research Group, have managed and supervised an international cooperation study, in order to present a general review of the innovative surgical applications, focused on anatomical systems, such as the nervous and craniofacial system, cardiovascular system, digestive system, genitourinary system, and musculoskeletal system. Finally, the integration with augmented, mixed, virtual reality is analyzed to show the advantages of personalized treatments, taking into account the improvements for preoperative, intraoperative planning, and medical training. Also, this article explores the creation of devices and tools for space surgery to get better outcomes under changing gravity conditions.


  • Reverse engineering human brain evolution using organoid models

    by Mohammed A. Mostajo-Radji, Matthew T. Schmitz, Sebastian Torres Montoya, Alex A. Pollen


  • Surface and Thermal Characteristics of Single-Use Electrosurgical Pencils After Clinical Reuse and In-Hospital Reprocessing

    by Francesco Tessarolo, Sebastian Torres, Luis Miguel Ballesteros, Marta Rigoni, Federico Piccoli, Iole Caola, Patrizio Caciagli, Yesid Montoya, Giandomenico Nollo

    Safety and efficacy issues are associated with reprocessing of single-use electrosurgical pencils (EPs), requiring methods for assessing the reprocessing protocol before clinical reuse. This study aimed at monitoring the surface characteristics of single-use EPs subjected to multiple clinical use and in-hospital reprocessing. A total of 24 single-use-labeled EPs were divided in five test groups and one control group. The test groups were subjected to a different number of clinical uses, ranging from one to five. A multitechnique approach based on optical stereomicroscopy (OM), scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDXS), differential scanning calorimetry (DSC), and thermogravimetric analysis (TGA) was applied. The silicon coating of the tip was significantly reduced, and foreign bodies were occasionally found on reprocessed EPs. The amount of biological debris and chemical residuals increased with the number of reprocessing cycles in critical areas. The degradation temperature of the EP handle polymer showed a progressive significant reduction. Cable cord showed no modification after reprocessing. EP tip could undergo major surface modifications that can affect functionality. The efficacy of the reprocessing protocol in removing debris from the EP handle should be carefully assessed. Surface and thermal characteristics have to be considered for validating a reprocessing protocol of single-use labeled EP.


  • Cocreation laboratory in health: Materialization tool for innovation process in Colombian public hospitals

    by M. Sebastian Torres, C. Juan Cardenas, L. Alejandro Arenas, P. Alvaro Quintero, V. Robinson Torres

    Although there is a considerable investment in research for overall health, only the 1% of Colombian hospitals and clinical institutions, known as IPS, can afford innovation processes, this phenomenon implies a short generation of intellectual assets in health-care system in Colombia is shown. To standardize innovation process, healthcare organizations must identify their capabilities to implement research, innovation and development activities; The General Hospital of Medellin (HGM) evaluated its own innovation capacities between 2010 and 2015, which resulted in the necessity to convert its strategic plan into innovative products and services. As result of this characterization, the HGM in alliance with the universities CES and EIA specialized in life science and engineering respectively, built an innovation strategy known as cocreation laboratory in health, which is understood as the place where engineering professionals, healthcare staff, and the community join forces to develop solutions prototypes to face in home hospital problems. The main objective of this strategy is to generate added value and increase the clinical and administrative hospital's capacities, in order to gain quality in the patient's attention.

  • A Multi-techniques Approach to assess reprocessing of Single-use electrosurgical pencils

    by Francesco Tessarolo, Sebastian Torres, Luis Ballesteros, Marta Rigoni, Federico Piccoli, Iole Caola, Yesid Montoya, Giandomenico Nollo

    Reprocessing and reuse of single-use electrosurgical pencils (EPs) is a diffused practice in countries with limited access to healthcare subvention system and in developing countries. However, safety and efficacy issues are associated to this practice, requiring specific methods for checking the reprocessed device before clinical re-use. This study aimed at defining a set of testing methods for assessing thermal and surface characteristics of reprocessed single-use EPs and evaluating the suitability of these techniques for revealing modifications between brand new and reprocessed single-use EPs. We reported a multi-technique approach based on optical and electron microscopy, X-rays spectroscopy and thermal analysis. The assessment of a total of 30 variables of interest on both brand new and reprocessed devices, allowed to identify the most informative ones. Seven of the evaluated variables were found to differentiate the reprocessed device from the new ones in a significant way. The presented methods deserve potential for tracking modifications during the device lifecycle.