Rapid 3D mandibular superimposition for growing patients
- 1 May 2017
- journal article
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 87 (3) , 473-479
Abstract
Objective: To evaluate the precision and reproducibility of a protocol to perform rapid voxel-based superimposition of the mandible in growing patients using CBCT. Materials and Methods: The sample comprised two cone-beam computed tomography scans taken at least 1 year apart from each of 24 growing patients. Voxel-based superimposition was performed by two examiners independently. The internal part of the symphysis extending to the first molar was used as the reference. The superimposition process took approximately 5 minutes. Once the mandibles were superimposed, surface models were created and root mean square (RMS) changes were obtained by means of iterative closest point. To evaluate precision, differences in three areas were measured between time point 1 (T1) and time point 2 (T2) superimposed. To evaluate reproducibility between different examiners, the distances between T2 superimposed by each operator were measured in five different areas. Descriptive statistics were used to evaluate the precision of the superimposition and the interexaminer reproducibility measurements for each case were reported individually. Results: The superimposition mean error between T1 and T2 for the right and left sides of the mandible and chin were 0.23 mm, 0.25 mm, and 0.33 mm, respectively. Interexaminer reproducibility error was ≤0.3 mm in 20 of 24 cases for measurements near the registration area. In the ramus area, two cases had errors >1 mm (1 mm–1.3 mm). Conclusion: The rapid superimposition was precise for assessing dentoalveolar changes and structures close to the registration area. However, evaluation of the condyles and ramus area had limitations and needs improvement.Keywords
This publication has 19 references indexed in Scilit:
- Influence of magnification and superimposition of structures on cephalometric diagnosisDental Press Journal of Orthodontics, 2015
- Comparison of the Accuracy of Voxel Based Registration and Surface Based Registration for 3D Assessment of Surgical Change following Orthognathic SurgeryPLOS ONE, 2014
- Superimposition of 3-dimensional cone-beam computed tomography models of growing patientsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2009
- Cephalometric SuperimpositionsThe Angle Orthodontist, 2008
- Superimposition of 3D cone-beam CT models of orthognathic surgery patientsDentomaxillofacial Radiology, 2005
- A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary resultsEuropean Radiology, 1998
- Normal and abnormal growth of the mandible. A synthesis of longitudinal cephalometric implant studies over a period of 25 yearsEuropean Journal of Orthodontics, 1983
- Facial development and tooth eruptionAmerican Journal of Orthodontics, 1972
- The reliability of head film measurementsAmerican Journal of Orthodontics, 1971
- The reliability of head film measurementsAmerican Journal of Orthodontics, 1971