MPPC Arrays in PET Detectors With LSO and BGO Scintillators
- 5 April 2013
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 60 (3) , 1533-1540
Abstract
Presently, a majority of studies concerning application of silicon photomultipliers (SiPMs) in positron emission tomography detectors are focused on scintillators containing lanthanum (LaBr3) or lutetium (LSO, LYSO, or LFS). However, the modules with the well-known BGO in combination with SiPM light readout are also interesting, owing unique features of SiPMs. In this paper, the two types of detectors, based on BGO and LSO scintillators, are compared in terms of requirements for positron emission tomography scanners. The presented studies are performed with two Hamamatsu Multi Pixel Photon Counter (MPPC) arrays of 2 × 2 channels, with the total area of 6 × 6 mm2 and micro-pixel size of 25 μm (S10985-025C) and 50 μm (S10985-050C). The measurements of a number of photoelectrons, energy resolution at 511 keV and 22Na time resolution are reported for various sizes of the scintillators, including 2.75 × 2.75 × 20 mm3 pixel and single crystals covering the whole MPPC active area. The paper is more focused on optimization of the system with BGO as its performance in combination with SiPM light readout is less known. The aim of this work is to show advantages of a SiPM-based detector, especially in combination with BGO, in respect to the block detectors where classic photomultipliers are used.Keywords
This publication has 9 references indexed in Scilit:
- Effective dead time of APD cells of SiPM2011
- Characterization of LFS-3 scintillator in comparison with LSONuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2011
- Efficiency of Solid State Photomultipliers in Photon Number ResolutionIEEE Transactions on Nuclear Science, 2011
- Characterisation studies of silicon photomultipliersNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2010
- Fast Photomultipliers for TOF PETIEEE Transactions on Nuclear Science, 2009
- Geiger-mode avalanche photodiodes, history, properties and problemsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2006
- New Prospects for Time-of-Flight PET With LSO ScintillatorsIEEE Transactions on Nuclear Science, 2006
- TUKAN-an 8K pulse height analyzer and multi-channel scaler with a PCI or a USB interfaceIEEE Transactions on Nuclear Science, 2006
- Time Resolution of Photomultiplier SystemsReview of Scientific Instruments, 1965