Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit
Open Access
- 14 January 2005
- journal article
- research article
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 94 (3) , 287-291
Abstract
Background. The USCOM ultrasonic cardiac output monitor (USCOM Pty Ltd, Coffs Harbour, NSW, Australia) is a non-invasive device that determines cardiac output by continuous-wave Doppler ultrasound. The aim of this study was to evaluate the accuracy of the USCOM device compared with the thermodilution technique in intensive care patients who had just undergone cardiac surgery. Methods. We conducted a prospective study in the 18-bed intensive care unit of a 600-bed tertiary referral hospital. Twenty-four mechanically ventilated patients were studied immediately following cardiac surgery. We evaluated the USCOM monitor by comparing its output with paired measurements obtained by the standard thermodilution technique using a pulmonary artery catheter. Results. Forty paired measurements were obtained in 22 patients. We were unable to obtain an acceptable signal in the remaining two patients. Comparison of the two techniques showed a bias of 0.18 and limits of agreement of −1.43 to 1.78. The agreement may not be as good between techniques at higher cardiac output values. Conclusions. The USCOM monitor has a place in intensive care monitoring. It is accurate, rapid, safe, well-tolerated, non-invasive and cost-effective. The learning curve for skill acquisition is very short. However, during the learning phase the USCOM monitor measurements are rather ‘operator dependent’. Its suitability for use in high and low cardiac output states requires further validation.Keywords
This publication has 12 references indexed in Scilit:
- Use of echocardiography for hemodynamic monitoringCritical Care Medicine, 2002
- A randomised, controlled trial of the pulmonary artery catheter in critically ill patientsIntensive Care Medicine, 2002
- Measurement of Cardiac Output by Transoesophageal Echocardiography: A Comparison of Two Doppler Methods with ThermodilutionAnaesthesia and Intensive Care, 1999
- The Effectiveness of Right Heart Catheterization in the Initial Care of Critically III PatientsJAMA, 1996
- New perspectives in the assessment of cardiac chamber dimensions during development and adulthoodJACC, 1992
- Continuous wave doppler cardiac output: Use in pediatric patients receiving inotropic supportPediatric Cardiology, 1988
- Comparison between ultrasonic and thermodilution cardiac output measurements in intensive care patientsCritical Care Medicine, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Noninvasive Measurement of Cardiac Output by Continuous-Wave Doppler Echocardiography: Initial Experience and Review of the LiteratureMayo Clinic Proceedings, 1984
- A new technique for measurement of cardiac output by thermodilution in manThe American Journal of Cardiology, 1971