P Vernon Van Heerden
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
P Vernon Van Heerden has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Adrian Regli
Intensive Care Unit, SJOG Murdoch Hospital, Murdoch, WA, Australia; Intensive Care Unit, Fiona Stanley Hospital, Murdoch, WA, Australia; Division of Emergency Medicine, Anaesthesia and Pain Medicine, Medical School, The University of Western Australia, Nedlands, WA, Australia; Medical School, The University of Notre Dame, Fremantle, WA, Australia
1 shared publication B. Roberts
Department of Intensive Care, Sir Charles Gairdner Hospital and Pharmacology Unit, School of Medicine and Pharmacology, University of Western Australia, Perth, Australia
1 shared publication- Bart De Keulenaer
Intensive Care, Fiona Stanley Hospital, Murdoch, Western Australia, Australia
1 shared publication - Bhajan Singh
Western Australian Sleep Disorders Research Institute, Sir Charles Gairdner Hospital Nedlands Western Australia Australia
1 shared publication - Bill Noffsinger
Department of Pulmonary Physiology and Sleep Medicine, Sir Charles Gairdner Hospital, Hospital Avenue, 6009 Nedlands, Australia
1 shared publication - Brigit Roberts
Sir Charles Gairdner Hospital, Perth, WA, Australia
1 shared publication
Latest Publications
- Open Access
- 26 October 2012
- Published by Springer Nature in Critical Care
- Vol. 16 (5) , R208
Matching positive end-expiratory pressure to intra-abdominal pressure improves oxygenation in a porcine sick lung model of intra-abdominal hypertension
Introduction: Intra-abdominal hypertension (IAH) causes atelectasis, reduces lung volumes and increases respiratory system elastance. Positive end-expiratory pressure (PEEP) in the setting of IAH and healthy lungs improves lung volumes but not oxygenation. However, critically ill patients with IAH often suffer from acute lung injury (ALI). This study, therefore, examined the respiratory and cardiac effects of positive end-expiratory pressure in an animal model of IAH, with sick lungs. Methods: Nine pigs were anesthetized and ventilated (48 +/- 6 kg). Lung injury was induced with oleic acid. Three levels of intra-abdominal pressure (baseline, 18, and 22 mmHg) were randomly generated. At each level of intra-abdominal pressure, three levels of PEEP were randomly applied: baseline (5 cmH2O), moderate (0.5 × intra-abdominal pressure), and high (1.0 × intra-abdominal pressure). We measured end-expiratory lung volumes, arterial oxygen levels, respiratory mechanics, and cardiac output 10 minutes after each new IAP and PEEP setting. Results: At baseline PEEP, IAH (22 mmHg) decreased oxygen levels (-55%, P P = 0.007). At IAP of 22 mmHg, moderate and high PEEP increased oxygen levels (+60%, P = 0.04 and +162%, P P = 0.02 and +279%, P P = 0.04). Shunt and dead-space fraction inversely correlated with oxygen levels and end-expiratory lung volumes. In the presence of IAH, lung, chest wall and respiratory system elastance increased. Subsequently, PEEP decreased respiratory system elastance by decreasing chest wall elastance. Conclusions: In a porcine sick lung model of IAH, PEEP matched to intra-abdominal pressure led to increased lung volumes and oxygenation and decreased chest wall elastance shunt and dead-space fraction. High PEEP decreased cardiac output. The study shows that lung injury influences the effects of IAH and PEEP on oxygenation and respiratory mechanics. Our findings support the application of PEEP in the setting of acute lung injury and IAH.
- 26 October 2012
- Published by Springer Nature in Critical Care
- Vol. 16 (5) , R208
Open AccessMatching positive end-expiratory pressure to intra-abdominal pressure improves oxygenation in a porcine sick lung model of intra-abdominal hypertension
Introduction: Intra-abdominal hypertension (IAH) causes atelectasis, reduces lung volumes and increases respiratory system elastance. Positive end-expiratory pressure (PEEP) in the setting of IAH and healthy lungs improves lung volumes but not oxygenation. However, critically ill patients with IAH often suffer from acute lung injury (ALI). This study, therefore, examined the respiratory and cardiac effects of positive end-expiratory pressure in an animal model of IAH, with sick lungs. Methods: Nine pigs were anesthetized and ventilated (48 +/- 6 kg). Lung injury was induced with oleic acid. Three levels of intra-abdominal pressure (baseline, 18, and 22 mmHg) were randomly generated. At each level of intra-abdominal pressure, three levels of PEEP were randomly applied: baseline (5 cmH2O), moderate (0.5 × intra-abdominal pressure), and high (1.0 × intra-abdominal pressure). We measured end-expiratory lung volumes, arterial oxygen levels, respiratory mechanics, and cardiac output 10 minutes after each new IAP and PEEP setting. Results: At baseline PEEP, IAH (22 mmHg) decreased oxygen levels (-55%, P P = 0.007). At IAP of 22 mmHg, moderate and high PEEP increased oxygen levels (+60%, P = 0.04 and +162%, P P = 0.02 and +279%, P P = 0.04). Shunt and dead-space fraction inversely correlated with oxygen levels and end-expiratory lung volumes. In the presence of IAH, lung, chest wall and respiratory system elastance increased. Subsequently, PEEP decreased respiratory system elastance by decreasing chest wall elastance. Conclusions: In a porcine sick lung model of IAH, PEEP matched to intra-abdominal pressure led to increased lung volumes and oxygenation and decreased chest wall elastance shunt and dead-space fraction. High PEEP decreased cardiac output. The study shows that lung injury influences the effects of IAH and PEEP on oxygenation and respiratory mechanics. Our findings support the application of PEEP in the setting of acute lung injury and IAH.
- 1 December 2008
- Vol. 10 (4) , 332-3
What's in a name?
- Open Access
- 1 September 2005
- Published by Elsevier in Critical Care and Resuscitation
- Vol. 7 (3) , 158-159
Australasian talent to the fore
- 1 September 2005
- Published by Elsevier in Critical Care and Resuscitation
- Vol. 7 (3) , 158-159
Open AccessAustralasian talent to the fore
- Open Access
- 14 January 2005
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 94 (3) , 287-291
Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit
Background. The USCOM ultrasonic cardiac output monitor (USCOM Pty Ltd, Coffs Harbour, NSW, Australia) is a non-invasive device that determines cardiac output by continuous-wave Doppler ultrasound. The aim of this study was to evaluate the accuracy of the USCOM device compared with the thermodilution technique in intensive care patients who had just undergone cardiac surgery. Methods. We conducted a prospective study in the 18-bed intensive care unit of a 600-bed tertiary referral hospital. Twenty-four mechanically ventilated patients were studied immediately following cardiac surgery. We evaluated the USCOM monitor by comparing its output with paired measurements obtained by the standard thermodilution technique using a pulmonary artery catheter. Results. Forty paired measurements were obtained in 22 patients. We were unable to obtain an acceptable signal in the remaining two patients. Comparison of the two techniques showed a bias of 0.18 and limits of agreement of −1.43 to 1.78. The agreement may not be as good between techniques at higher cardiac output values. Conclusions. The USCOM monitor has a place in intensive care monitoring. It is accurate, rapid, safe, well-tolerated, non-invasive and cost-effective. The learning curve for skill acquisition is very short. However, during the learning phase the USCOM monitor measurements are rather ‘operator dependent’. Its suitability for use in high and low cardiac output states requires further validation.
- 14 January 2005
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 94 (3) , 287-291
Open AccessClinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit
Background. The USCOM ultrasonic cardiac output monitor (USCOM Pty Ltd, Coffs Harbour, NSW, Australia) is a non-invasive device that determines cardiac output by continuous-wave Doppler ultrasound. The aim of this study was to evaluate the accuracy of the USCOM device compared with the thermodilution technique in intensive care patients who had just undergone cardiac surgery. Methods. We conducted a prospective study in the 18-bed intensive care unit of a 600-bed tertiary referral hospital. Twenty-four mechanically ventilated patients were studied immediately following cardiac surgery. We evaluated the USCOM monitor by comparing its output with paired measurements obtained by the standard thermodilution technique using a pulmonary artery catheter. Results. Forty paired measurements were obtained in 22 patients. We were unable to obtain an acceptable signal in the remaining two patients. Comparison of the two techniques showed a bias of 0.18 and limits of agreement of −1.43 to 1.78. The agreement may not be as good between techniques at higher cardiac output values. Conclusions. The USCOM monitor has a place in intensive care monitoring. It is accurate, rapid, safe, well-tolerated, non-invasive and cost-effective. The learning curve for skill acquisition is very short. However, during the learning phase the USCOM monitor measurements are rather ‘operator dependent’. Its suitability for use in high and low cardiac output states requires further validation.
- 1 September 2003
- Published by Wiley in Clinical and Experimental Pharmacology and Physiology
- Vol. 30 (9) , 709-711
Diethylenetriamine NITRIC oxide adduct relaxes precontracted mouse tracheal smooth muscle*
- 1 September 2003
- Published by Wiley in Clinical and Experimental Pharmacology and Physiology
- Vol. 30 (9) , 709-711
Diethylenetriamine NITRIC oxide adduct relaxes precontracted mouse tracheal smooth muscle*