BACKGROUND: The objective of the current study was to establish a process for validating immunohistochemistry (IHC) protocols for use on the Cellient cell block (CCB) system.METHODS: Thirty antibodies were initially tested on CCBs using IHC protocols previously validated on formalin‐fixed, paraffin‐embedded tissue (FFPE). Cytology samples were split to generate thrombin cell blocks (TCB) and CCBs. IHC was performed in parallel. Antibody immunoreactivity was scored, and concordance or discordance in immunoreactivity between the TCBs and CCBs for each sample was determined. Criteria for validation of an antibody were defined as concordant staining in expected positive and negative cells, in at least 5 samples each, and concordance in at least 90% of the samples total. Antibodies that failed initial validation were retested after alterations in IHC conditions.RESULTS: Thirteen of the 30 antibodies (43%) did not meet initial validation criteria. Of those, 8 antibodies (calretinin, clusters of differentiation [CD] 3, CD20, CDX2, cytokeratin 20, estrogen receptor, MOC‐31, and p16) were optimized for CCBs and subsequently validated. Despite several alterations in conditions, 3 antibodies (Ber‐EP4, D2‐40, and paired box gene 8 [PAX8]) were not successfully validated.CONCLUSIONS: Nearly one‐half of the antibodies tested in the current study failed initial validation using IHC conditions that were established in the study laboratory for FFPE material. Although some antibodies subsequently met validation criteria after optimization of conditions, a few continued to demonstrate inadequate immunoreactivity. These findings emphasize the importance of validating IHC protocols for methanol‐fixed tissue before clinical use and suggest that optimization for alcohol fixation may be needed to obtain adequate immunoreactivity on CCBs. Cancer (Cancer Cytopathol) 2016;124:89‐99. © 2016 American Cancer Society.Keywords
This publication has 17 references indexed in Scilit:
- Principles of Analytic Validation of Immunohistochemical Assays: Guideline From the College of American Pathologists Pathology and Laboratory Quality CenterArchives of Pathology & Laboratory Medicine, 2014
- Effective application of the methanol‐based PreservCyt™ fixative and the Cellient™ automated cell block processor to diagnostic cytopathology, immunocytochemistry, and molecular biologyDiagnostic Cytopathology, 2013
- Preparation of DNA from cytological materialCancer Cytopathology, 2013
- Morphologic and Immunocytochemical Performances of Effusion Cell Blocks Prepared Using 3 Different MethodsAmerican Journal of Clinical Pathology, 2013
- Immunohistochemistry Validation Procedures and Practices: A College of American Pathologists Survey of 727 LaboratoriesArchives of Pathology & Laboratory Medicine, 2013
- Immunohistochemical detection of estrogen receptor, progesterone receptor and human epidermal growth factor receptor 2 in formalin‐fixed breast carcinoma cell block preparations: Correlation of results to corresponding tissue block (needle core and excision) samplesDiagnostic Cytopathology, 2012
- Comparison of Breast Carcinoma Prognostic/Predictive Biomarkers on Cell Blocks Obtained by Various Methods: Cellient, Formalin and ThrombinActa Cytologica, 2012
- Cellient™ automated cell block versus traditional cell block preparation: A comparison of morphologic features and immunohistochemical stainingDiagnostic Cytopathology, 2010
- Immunohistochemical detection of estrogen receptor, progesterone receptor, and human epidermal growth factor receptor 2 expression in breast carcinomasCancer Cytopathology, 2009
- Effect of Fixatives and Tissue Processing on the Content and Integrity of Nucleic AcidsThe American Journal of Pathology, 2002