The use of reference image criteria in X-ray diagnostics: an application for the optimisation of lumbar spine radiographs
- 1 April 2004
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 14 (9) , 1561-1567
Abstract
To ensure that sufficient image quality is obtained in diagnostic radiology, the image quality of clinical radiographs has to be evaluated. We present two methods herein for evaluating antero-posterior (AP) radiographs of the lumbar spine. One was using image criteria, including six anatomical details (absolute method). In the other, the visibility of anatomical details relative to a reference radiograph was evaluated (visual grading analysis). In total, 14 technique groups were evaluated. The technique groups differed in tube voltage and detector system characteristics. Six different gradients of the H&D curves were simulated. The visual grading analysis showed larger differences in image quality compared with the absolute method. The influence on the image quality due to a variation in tube voltage was easier to detect than the influence on the image quality from the detector characteristics. The visibility of the anatomical details was significantly dependent on the location in the spine. The visual grading analysis was found to be the preferable evaluation method in studies such as the present; however, it is necessary to guide and train the observer before the evaluation is performed.Keywords
This publication has 11 references indexed in Scilit:
- Comparison of Entrance Surface Doses of Some X Ray Examinations with CEC Reference DosesRadiation Protection Dosimetry, 2002
- The influence of different technique factors on image quality of chest radiographs as evaluated by modified CEC image quality criteriaBritish Journal of Radiology, 2002
- Experiences with the European guidelines on quality criteria for radiographic images in TanzaniaJournal of Applied Clinical Medical Physics, 2001
- Image quality vs radiation dose for a flat-panel amorphous silicon detector: a phantom studyEuropean Radiology, 2001
- The influence of different technique factors on image quality of lumbar spine radiographs as evaluated by established CEC image criteria.British Journal of Radiology, 2000
- Erbium filtration: a cost-effective, dose-reducing filter which maintains abdominal image qualityEuropean Radiology, 1999
- Image quality for five modern chest radiography techniques: a modified FROC study with an anthropomorphic chest phantomEuropean Radiology, 1999
- Report of an image quality and dose audit according to directive 97/43/Euratom at Spanish private radiodiagnostics facilities.British Journal of Radiology, 1999
- Examination Technique, Image Quality, and Patient Dose in Paediatric RadiologyActa Radiologica, 1996
- Patient dose and image quality in five standard x‐ray examinationsMedical Physics, 1993