Electrically Evoked Compound Action Potential Amplitude Growth Functions and HiResolution Programming Levels in Pediatric CII Implant Subjects
Authors:
- Kevin H. FranckKFKevin H. Franck
- 1 December 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 25 (6) , 528-538
Abstract
To characterize the amplitude growth functions of the electrically evoked compound action potential (ECAP) in pediatric subjects implanted with the Clarion HiFocus electrode array with respect to electrode position and the presence or absence of a Silastic positioner. Electrophysiologic growth function data are compared with HiResolution (HiRes) psychophysical programming levels. ECAP growth functions were measured for all electrodes along the implant’s array in 16 pediatric subjects. Nine of the patients were implanted with a Silastic positioner, whereas seven had no positioner. ECAP thresholds and growth function slopes were calculated. Fifteen of the 16 patients had psychophysical threshold and maximum comfort levels available. Programming levels and ECAP thresholds were compared within and among the subjects. ECAP thresholds showed variability among patients, ranging from 178 to 920 nA at 32 μsec pulse width. ECAP thresholds did not depend on electrode position along the cochlea but were lower in the presence of the Silastic positioner (p < 0.001). Thresholds determined with the masker-probe versus the alternating polarity paradigms revealed moderate (r = 0.76) correlation. Growth function slopes also showed considerable variation among patients. Unlike thresholds, slopes decreased from apical to basal cochlear locations (p < 0.001) but showed no difference between the absence and presence of the positioner. Programming levels in HiRes were correlated with ECAP threshold levels. When ECAP thresholds were adjusted for each patient by the difference between M level and ECAP threshold at electrode 9, however, overall correlation between the two measurements was excellent (r = 0.98, N = 224). In pediatric subjects with the Clarion HiFocus electrode, ECAP growth function thresholds appear to decrease with the presence of the Silastic positioner but are unaffected by electrode position along the array. Growth function slope, however, depends on electrode position along the array but not on the presence of the positioner. ECAP programming levels can reliably predict stimulus intensities within the patients’ dynamic ranges, but considerable variability is seen between ECAP thresholds and HiRes programming levels.Keywords
This publication has 23 references indexed in Scilit:
- Electrically Evoked Auditory Brain Stem Responses for Lateral and Medial Placement of the Clarion HiFocus ElectrodeEar & Hearing, 2003
- Effects of Clarion Electrode Design on Mapping Levels in ChildrenAnnals of Otology, Rhinology & Laryngology, 2002
- Estimation of Psychophysical Levels Using the Electrically Evoked Compound Action Potential Measured with the Neural Response Telemetry Capabilities of Cochlear Corporation???s CI24M DeviceEar & Hearing, 2001
- Effects of the Clarion Electrode Positioning System on Auditory Thresholds and Comfortable Loudness Levels in Pediatric Patients With Cochlear ImplantsJAMA Otolaryngology–Head & Neck Surgery, 2001
- The Relationship Between EAP and EABR Thresholds and Levels Used to Program the Nucleus 24 Speech Processor: Data from AdultsEar & Hearing, 2000
- A silastic positioner for a modiolus-hugging position of intracochlear electrodes: electrophysiologic effects.American Journal of Otolaryngology, 2000
- The Clarion electrode positioner: temporal bone studies.American Journal of Otolaryngology, 2000
- Electrically Evoked Whole Nerve Action Potentials in Ineraid Cochlear Implant Users: Responses to Different Stimulating Electrode Configurations and Comparison to Psychophysical ResponsesJournal of Speech, Language, and Hearing Research, 1996
- Electrically evoked whole-nerve action potentials: Data from human cochlear implant usersThe Journal of the Acoustical Society of America, 1990
- Electric Current Measurement in Terms of Length, Mass, and TimeAn Undergraduate ExperimentJournal of the Optical Society of America, 1929