Evaluation of Dimensional Deviations Across a Digital-to-Physical Workflow for Orthodontic Appliance Fabrication Using CAD Surface Inspection
Open Access
Abstract
Digital-to-physical orthodontic workflows combine intraoral scanning, 3D printing, rescanning and thermoforming, but each step may introduce dimensional deviation affecting final appliance geometry. This pilot methodological study evaluated relative dimensional deviations across selected stages of a biomedical manufacturing workflow for orthodontic appliances. Anonymized intraoral scan datasets from two patients with eugnathic occlusion were used, providing four arch-level datasets. CAD inspection compared IOS data, printed models, powder-coated printed models, and thermoformed appliances, with an analysis of global RMS surface deviation, anterior/posterior regional differences, spray-related surface offset and material-thickness effects. The highest mean global RMS deviation was found for IOS vs. a printed model (0.090 mm), followed by IOS vs. a powder-coated model (0.088 mm), whereas the direct printed model vs. powder-coated model comparison showed a lower mean RMS deviation of 0.039 mm. Regional analysis showed higher RMS deviations posteriorly (0.077 mm) than anteriorly (0.047 mm). Thermoformed appliance adaptation was affected by material thickness, with a mean RMS deviation of 0.207 mm for 1.0 mm material and 0.282 mm for 1.5 mm material. Local incisor analysis estimated the spray-related surface offset at approximately 0.030 mm. The main dimensional discrepancy was associated with printed model fabrication, while posterior regions and thicker thermoformed material showed greater deviation.Keywords
Funding Information
- Provincial Secretariat for Science and Technological Development (0038856804 2025 09418 003 000 000 001)
This publication has 39 references indexed in Scilit:
- Fit analysis of 3D-printed versus thermoformed clear aligners for labial tooth movement using micro-CT: an in vitro studyScientific Reports, 2026
- Effect of 3D printing technology, build orientation, and shell thickness on the accuracy of full-arch dental models for fixed dental prostheses: an in vitro studyScientific Reports, 2025
- An in-vitro study on factors influencing the accuracy of current intraoral scannersScientific Reports, 2025
- Accuracy of full arch scans performed with nine different scanning patterns– an in vitro studyClinical Oral Investigations, 2025
- The influence of 3-dimensional printing layer thickness on model accuracy and the perceived fit of thermoformed retainersAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2025
- Effect of scan powder and scanning technology on measured deviations of complete-arch implant supported frameworks digitized with industrial and intraoral scannersJournal of Dentistry, 2023
- Comparison of translucency, thickness, and gap width of thermoformed and 3D-printed clear aligners using micro-CT and spectrophotometerScientific Reports, 2023
- A comparison of trueness and precision of 12 3D printers used in dentistryBDJ Open, 2022
- Evaluation of the dimensional accuracy of thermoformed appliances taken from 3D printed models with varied shell thicknesses: An in vitro studyInternational Orthodontics, 2021
- Investigation into the accuracy and measurement methods of sequential 3D dental scan alignmentDental Materials, 2019