Natasa Puskar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Natasa Puskar has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Aleksandar Jakovljevic
Department of Pathophysiology, School of Dental Medicine University of Belgrade Belgrade Serbia
1 shared publication - Aleksandar Milosevic
University of Novi Sad, Faculty of Technical Sciences
1 shared publication Amar Đerlek
Department of Orthodontics and Dentofacial Orthopedics School of Dental Medicine University of Belgrade
1 shared publication- Danijela Radumilo
Faculty of Medicine, University of Novi Sad, Hajduk Veljkova 3, 21000 Novi Sad, Serbia
1 shared publication - Djordje Vukelic
University of Novi Sad, Faculty of Technical Sciences
1 shared publication - Hisham Sabbagh
Department of Orthodontics and Dentofacial Orthopedics, University Hospital, LMU Munich, Goethestrasse 70, 80336 Munich, Germany
1 shared publication
Latest Publications
- Open Access
Evaluation of Dimensional Deviations Across a Digital-to-Physical Workflow for Orthodontic Appliance Fabrication Using CAD Surface Inspection
Digital-to-physical orthodontic workflows combine intraoral scanning, 3D printing, rescanning and thermoforming, but each step may introduce dimensional deviation affecting final appliance geometry. This pilot methodological study evaluated relative dimensional deviations across selected stages of a biomedical manufacturing workflow for orthodontic appliances. Anonymized intraoral scan datasets from two patients with eugnathic occlusion were used, providing four arch-level datasets. CAD inspection compared IOS data, printed models, powder-coated printed models, and thermoformed appliances, with an analysis of global RMS surface deviation, anterior/posterior regional differences, spray-related surface offset and material-thickness effects. The highest mean global RMS deviation was found for IOS vs. a printed model (0.090 mm), followed by IOS vs. a powder-coated model (0.088 mm), whereas the direct printed model vs. powder-coated model comparison showed a lower mean RMS deviation of 0.039 mm. Regional analysis showed higher RMS deviations posteriorly (0.077 mm) than anteriorly (0.047 mm). Thermoformed appliance adaptation was affected by material thickness, with a mean RMS deviation of 0.207 mm for 1.0 mm material and 0.282 mm for 1.5 mm material. Local incisor analysis estimated the spray-related surface offset at approximately 0.030 mm. The main dimensional discrepancy was associated with printed model fabrication, while posterior regions and thicker thermoformed material showed greater deviation.
Open AccessEvaluation of Dimensional Deviations Across a Digital-to-Physical Workflow for Orthodontic Appliance Fabrication Using CAD Surface Inspection
Digital-to-physical orthodontic workflows combine intraoral scanning, 3D printing, rescanning and thermoforming, but each step may introduce dimensional deviation affecting final appliance geometry. This pilot methodological study evaluated relative dimensional deviations across selected stages of a biomedical manufacturing workflow for orthodontic appliances. Anonymized intraoral scan datasets from two patients with eugnathic occlusion were used, providing four arch-level datasets. CAD inspection compared IOS data, printed models, powder-coated printed models, and thermoformed appliances, with an analysis of global RMS surface deviation, anterior/posterior regional differences, spray-related surface offset and material-thickness effects. The highest mean global RMS deviation was found for IOS vs. a printed model (0.090 mm), followed by IOS vs. a powder-coated model (0.088 mm), whereas the direct printed model vs. powder-coated model comparison showed a lower mean RMS deviation of 0.039 mm. Regional analysis showed higher RMS deviations posteriorly (0.077 mm) than anteriorly (0.047 mm). Thermoformed appliance adaptation was affected by material thickness, with a mean RMS deviation of 0.207 mm for 1.0 mm material and 0.282 mm for 1.5 mm material. Local incisor analysis estimated the spray-related surface offset at approximately 0.030 mm. The main dimensional discrepancy was associated with printed model fabrication, while posterior regions and thicker thermoformed material showed greater deviation.
- Open Access
Nasal Fracture During Maxillary Expansion—A Rare Complication?
Background and Clinical Significance: This case report describes an unusual complication in an 8-year-old female patient undergoing ME (maxillary expansion) with a tooth-supported maxillary expander with the hyrax screw. Case presentation: After the 36th screw turn in the 5th week of treatment, the patient reported pressure and pain symptoms and the patient’s parents observed a bone elevation at the bridge of the nose. The patient was referred to for clinical examination which revealed a bilateral infraorbital hematoma and a movable, and highly sensitive, nasal area upon palpation. A cone-beam computed tomography (CBCT) scan confirmed a displaced nasal bone fracture. Conservative treatment was immediately initiated by reversing the hyrax screw four times, followed by ten additional turns over the next 7 days for a total of 14 back-turns. This procedure led to an immediate improvement in symptoms. An 8-week follow-up CBCT confirmed the physiological repositioning of the nasal bones and healing of the fracture. Conclusions: Although nasal bone fracture is a rare complication of ME, particularly in children, clinicians should be aware of this potential risk and remain vigilant for symptoms of high pressure and pain in the orbito-nasal area. If a nasal fracture is suspected during orthodontic treatment, the orthodontist should immediately cease screw activation. In selected cases, careful reversal of the screw, as described in this report, may be considered as a conservative treatment.
Open AccessNasal Fracture During Maxillary Expansion—A Rare Complication?
Background and Clinical Significance: This case report describes an unusual complication in an 8-year-old female patient undergoing ME (maxillary expansion) with a tooth-supported maxillary expander with the hyrax screw. Case presentation: After the 36th screw turn in the 5th week of treatment, the patient reported pressure and pain symptoms and the patient’s parents observed a bone elevation at the bridge of the nose. The patient was referred to for clinical examination which revealed a bilateral infraorbital hematoma and a movable, and highly sensitive, nasal area upon palpation. A cone-beam computed tomography (CBCT) scan confirmed a displaced nasal bone fracture. Conservative treatment was immediately initiated by reversing the hyrax screw four times, followed by ten additional turns over the next 7 days for a total of 14 back-turns. This procedure led to an immediate improvement in symptoms. An 8-week follow-up CBCT confirmed the physiological repositioning of the nasal bones and healing of the fracture. Conclusions: Although nasal bone fracture is a rare complication of ME, particularly in children, clinicians should be aware of this potential risk and remain vigilant for symptoms of high pressure and pain in the orbito-nasal area. If a nasal fracture is suspected during orthodontic treatment, the orthodontist should immediately cease screw activation. In selected cases, careful reversal of the screw, as described in this report, may be considered as a conservative treatment.
- Open Access
- 1 January 2025
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Balkan Journal of Dental Medicine
- Vol. 29 (2) , 81-89
Unraveling the cleft: A historical and comparative review of non-syndromic orofacial cleft etiology and classification
Background/Aim: Orofacial clefts are the most common birth defect of the head. Clefts arise due to a lack of tissue fusion during prenatal development. Various factors can cause the absence of fusion of these structures during 6-8th week of embryonic development. It is proven that the cause of non-syndromic orofacial clefts (NSOFCs) has multifactorial etiology. This review aims to provide a comprehensive summary on etiology and classification of NSOFCs. Material and Methods: Online bibliographic databases were utilized in order to find as many as possible available studies that showed a connection between any environmental factor and genes and NSCL/P, also available studies and books which represented any NSOFC classification system. Results: From the 35 articles and books reviewed, key etiological factors and numerous classification systems that developed over time have been identified. While the multifactorial nature is well-established and proven, specific percentage contributions of individual factors, either environmental or genetic, remain inconclusive. No single classification system is considered perfect, underscoring the need for continued research. Conclusions: Existing classification systems for NSOFCs all have advantages and disadvantages, lacking universal ease of use and comprehensiveness. However, they reflected the evolving understanding of NSOFCs, progressing from anatomical to embryological and developmental perspectives. While several potential etiological factors have been identified, the precise etiology of NSOFCs remain unclear due to complex interplay of factors involved in their occurrence. A definitive cause has not yet been identified.
- 1 January 2025
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Balkan Journal of Dental Medicine
- Vol. 29 (2) , 81-89
Open AccessUnraveling the cleft: A historical and comparative review of non-syndromic orofacial cleft etiology and classification
Background/Aim: Orofacial clefts are the most common birth defect of the head. Clefts arise due to a lack of tissue fusion during prenatal development. Various factors can cause the absence of fusion of these structures during 6-8th week of embryonic development. It is proven that the cause of non-syndromic orofacial clefts (NSOFCs) has multifactorial etiology. This review aims to provide a comprehensive summary on etiology and classification of NSOFCs. Material and Methods: Online bibliographic databases were utilized in order to find as many as possible available studies that showed a connection between any environmental factor and genes and NSCL/P, also available studies and books which represented any NSOFC classification system. Results: From the 35 articles and books reviewed, key etiological factors and numerous classification systems that developed over time have been identified. While the multifactorial nature is well-established and proven, specific percentage contributions of individual factors, either environmental or genetic, remain inconclusive. No single classification system is considered perfect, underscoring the need for continued research. Conclusions: Existing classification systems for NSOFCs all have advantages and disadvantages, lacking universal ease of use and comprehensiveness. However, they reflected the evolving understanding of NSOFCs, progressing from anatomical to embryological and developmental perspectives. While several potential etiological factors have been identified, the precise etiology of NSOFCs remain unclear due to complex interplay of factors involved in their occurrence. A definitive cause has not yet been identified.