Comparison of Flow Characteristics of Novel Three-Dimensional Printed Ureteral Stents Versus Standard Ureteral Stents in a Porcine Model
Authors:
- 1 September 2015
- journal article
- research article
- Published by SAGE Publications in Journal of Endourology
- Vol. 29 (9) , 1065-1069
Abstract
Purpose: We compared the flow characteristics of novel three-dimensional (3D) printed ureteral stents with four conventional double-pigtail stents in an ex vivo porcine model. Materials and Methods: In six ex vivo porcine urinary systems with kidneys and ureters intact, we deployed a 5F occlusion catheter in an interpolar calix. We tested each system with antegrade irrigation with a 0.9% saline bag placed 35 cm above the renal pelvis. We evaluated four standard stents (6F Universa® Soft, 7F Percuflex,™ 7/10F Applied Endopyelotomy, 8.5F Filiform Double Pigtail) and compared them with a 9F 3D printed prototype stent. For each stent, we measured the total, extraluminal, and intraluminal flow rates. Results: The mean total flow rates for 3D printed stents were significantly higher than the 6F, 7F, and 7/10F stents (PPPPPConclusions: In this pilot study, 3D printed stents manifested a mean total flow rate comparable to the flow rates of contemporary stents. Continued advances in technology and material may permit functionally feasible 3D printed ureteral stents.Keywords
This publication has 22 references indexed in Scilit:
- Drainage Characteristics of the 3F MicroStent Using a Novel Film Occlusion Anchoring MechanismJournal of Endourology, 2011
- Predictors of morbidity in patients with indwelling ureteric stents: results of a prospective study using the validated Ureteric Stent Symptoms QuestionnaireBJU International, 2011
- A Novel Thermo-Expandable Ureteral Metal Stent for the Minimally Invasive Management of Ureteral StricturesJournal of Endourology, 2010
- Determining the Appropriate Length of a Double-Pigtail Ureteral Stent by Both Stent Configurations and Related SymptomsJournal of Endourology, 2008
- Self-Retaining Ureteral Stents: Analysis of Factors Responsible For Patients' DiscomfortJournal of Endourology, 2006
- Have Stent-Related Symptoms Anything to Do with Placement Technique?Journal of Endourology, 2001
- Mechanism of Ureteral Stent Flow: A Comparative in Vivo StudyJournal of Endourology, 1999
- Proximal Ureteral Stent Migration: An Avoidable Complication?Journal of Urology, 1996
- Which Ureteric Stent Length?British Journal of Urology, 1991
- The Effects of Double J Stenting on Unobstructed Ureters. An Experimental and Clinical Study*British Journal of Urology, 1985