Jaime Landman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jaime Landman has a total of 253 co-authors. Here are the top co-authors by number of shared publications:
Zhamshid Okhunov
Department of Urology, University of California, Irvine
28 shared publications- Roshan M. Patel
Department of Urology, University of California, Irvine, California
11 shared publications Achim Lusch
Department of Urology, University of California, Irvine, Orange, California
10 shared publicationsRenai Yoon
Department of Urology, University of California, Orange, CA
10 shared publicationsMichael del Junco
7 shared publicationsRalph V. Clayman
Department of Urology, University of California, Irvine
7 shared publications
Latest Publications
- 1 October 2024
- Published by SAGE Publications in Journal of Endourology
- Vol. 38 (10) , 1075-1081
Development and Initial Evaluation of a Cost-Effective Force Sensor for Ureteroscopic Application
Purpose: Retrograde intrarenal surgery is the gold-standard treatment for most kidney stones. During ureteroscopy, ureteral access sheath insertion at forces greater than 8.0 Newtons (N) risks high-grade ureteral injury. To monitor force, our institution utilizes a unique, Bluetooth-equipped device (i.e., the University of California—Irvine Force Sensor). Given the unique nature of the force sensor, we sought to develop an inexpensive and accessible force sensor based on Boyle’s law and the specific amount of force required to compress an occluded 1.0 mL syringe. Materials and Methods: We evaluated three brands of 1.0 mL syringes. After setting the plunger at 1.0 mL, the syringe was occluded, and the syringe plunger was compressed. The syringe volume was recorded when the applied force on the plunger reached 4.0 N, 6.0 N, and 8.0 N. Multiple trials were performed to assess reliability and reproducibility. A method for applying this clinically was also developed. Results: The precise force thresholds identified for a 1.0 mL Luer-Lok™ Syringe (Becton Dickinson, Franklin Lakes, NJ) were 0.30 mL for 4.00 N, 0.20 mL for 6.00 N, and 0.15 mL for 8.00 N. The 1.0 mL Tuberculin Syringe and 1.0 mL Luer Slip Syringe were less precise, but compression from 1.0 to 0.40 mL, 0.25 mL, and 0.20 mL corresponded to force sensor readings that did not exceed 4.00 N, 6.00 N, and 8.00 N, respectively. Conclusions: Based on volume changes, 4.00 N, 6.00 N, and 8.00 N of force can be reliably and reproducibly achieved using an occluded 1.0 mL syringe.
- 1 October 2024
- Published by SAGE Publications in Journal of Endourology
- Vol. 38 (10) , 1075-1081
Development and Initial Evaluation of a Cost-Effective Force Sensor for Ureteroscopic Application
Purpose: Retrograde intrarenal surgery is the gold-standard treatment for most kidney stones. During ureteroscopy, ureteral access sheath insertion at forces greater than 8.0 Newtons (N) risks high-grade ureteral injury. To monitor force, our institution utilizes a unique, Bluetooth-equipped device (i.e., the University of California—Irvine Force Sensor). Given the unique nature of the force sensor, we sought to develop an inexpensive and accessible force sensor based on Boyle’s law and the specific amount of force required to compress an occluded 1.0 mL syringe. Materials and Methods: We evaluated three brands of 1.0 mL syringes. After setting the plunger at 1.0 mL, the syringe was occluded, and the syringe plunger was compressed. The syringe volume was recorded when the applied force on the plunger reached 4.0 N, 6.0 N, and 8.0 N. Multiple trials were performed to assess reliability and reproducibility. A method for applying this clinically was also developed. Results: The precise force thresholds identified for a 1.0 mL Luer-Lok™ Syringe (Becton Dickinson, Franklin Lakes, NJ) were 0.30 mL for 4.00 N, 0.20 mL for 6.00 N, and 0.15 mL for 8.00 N. The 1.0 mL Tuberculin Syringe and 1.0 mL Luer Slip Syringe were less precise, but compression from 1.0 to 0.40 mL, 0.25 mL, and 0.20 mL corresponded to force sensor readings that did not exceed 4.00 N, 6.00 N, and 8.00 N, respectively. Conclusions: Based on volume changes, 4.00 N, 6.00 N, and 8.00 N of force can be reliably and reproducibly achieved using an occluded 1.0 mL syringe.
- 1 April 2024
- Published by SAGE Publications in Journal of Endourology
- Vol. 38 (4) , 316-322
Surgical Force: Initial Study and Clinical Implications in the Assessment of Ureteral Access Sheath Induced Injury
Purpose: Ureteral access sheaths (UAS) pose the risk of severe ureteral injury. Our prior studies revealed forces ≤6 Newtons (N) prevent ureteral injury. Accordingly, we sought to define the force urologists and residents in training typically use when placing a UAS. Materials and Methods: Among urologists and urology residents attending two annual urological conferences in 2022, 121 individuals were recruited for the study. Participants inserted 12F, 14F, and 16F UAS into a male genitourinary model containing a concealed force sensor; they also provided demographic information. Analysis was completed using t -tests and Chi-square tests to identify group differences when passing a 16F sheath UAS. Participant traits associated with surpassing or remaining below a minimal force threshold were also explored through polychotomous logistic regression. Results: Participant force distributions were as follows: ≤4N (29%), >6N (45%), and >8N (32%). More years of practice were significantly associated with exerting >6N relative to forces between 4N and 6N; results for >8N relative to 4N and 8N were similar. Compared to high-volume ureteroscopists (those performing >20 ureteroscopies/month), physicians performing ≤20 ureteroscopies/month were significantly less likely to exert forces ≤4N ( p = 0.017 and p = 0.041). Of those surpassing 6N and 8N, 15% and 18%, respectively, were high-volume ureteroscopists. Conclusions: Despite years of practice or volume of monthly ureteroscopic cases performed, most urologists failed to pass 16F access sheaths within the ideal range of 4N to 6N (74% of participants) or within a predefined safe range of 4N to 8N (61% of participants).
- 1 April 2024
- Published by SAGE Publications in Journal of Endourology
- Vol. 38 (4) , 316-322
Surgical Force: Initial Study and Clinical Implications in the Assessment of Ureteral Access Sheath Induced Injury
Purpose: Ureteral access sheaths (UAS) pose the risk of severe ureteral injury. Our prior studies revealed forces ≤6 Newtons (N) prevent ureteral injury. Accordingly, we sought to define the force urologists and residents in training typically use when placing a UAS. Materials and Methods: Among urologists and urology residents attending two annual urological conferences in 2022, 121 individuals were recruited for the study. Participants inserted 12F, 14F, and 16F UAS into a male genitourinary model containing a concealed force sensor; they also provided demographic information. Analysis was completed using t -tests and Chi-square tests to identify group differences when passing a 16F sheath UAS. Participant traits associated with surpassing or remaining below a minimal force threshold were also explored through polychotomous logistic regression. Results: Participant force distributions were as follows: ≤4N (29%), >6N (45%), and >8N (32%). More years of practice were significantly associated with exerting >6N relative to forces between 4N and 6N; results for >8N relative to 4N and 8N were similar. Compared to high-volume ureteroscopists (those performing >20 ureteroscopies/month), physicians performing ≤20 ureteroscopies/month were significantly less likely to exert forces ≤4N ( p = 0.017 and p = 0.041). Of those surpassing 6N and 8N, 15% and 18%, respectively, were high-volume ureteroscopists. Conclusions: Despite years of practice or volume of monthly ureteroscopic cases performed, most urologists failed to pass 16F access sheaths within the ideal range of 4N to 6N (74% of participants) or within a predefined safe range of 4N to 8N (61% of participants).
- 29 January 2024
- Published by SAGE Publications in Journal of Endourology
- Vol. 38 (3) , 301-305
Utilization of Re-VASC, the Novel Retroperitoneal Neovascularity Scoring System, for Characterization of T1a Small Renal Masses
Purpose: Early characterization of small (T1a, < 4 cm) renal masses is imperative for patient care and treatment planning. Renal biopsy is a sensitive and specific procedure that can accurately differentiate small renal masses as malignant or benign. However, it is an invasive procedure with a non-negligible complication rate and is not performed routinely at most institutions. In this study, we sought to apply the Re-VASC scoring system to T1a renal masses and analyzed whether it could differentiate these masses as benign or malignant. Methods: We obtained Institutional Review Board approval to retrospectively examine the records of all patients who presented to our single, urban academic referral center for surgical treatment of renal cell carcinoma (RCC). For the malignant group, patients with a diagnosis of T1a RCC from pathologic evaluation were included. Additionally, patients with a histopathological diagnosis of a T1a non-malignant renal mass (fat poor-angiomyolipoma or oncocytoma) were included in our benign group. Results: This study includes 57 benign and 69 malignant T1a renal tumors. Average size for benign and malignant masses were 2.47 and 2.63 respectively (p=0.267). Analysis demonstrated no significant difference between both groups in terms of sex, laterality, or size. The average Re-VASC score of benign and malignant masses was 0.175 and malignant masses was 0.784 respectively (p<0.001). Additionally, the Re-VASC score was independently associated with malignancy with an odds ratio of 2.223 (p=0.0109). Conclusion: The Re-VASC scoring system exhibits significantly greater values for malignant T1a renal masses when compared to benign masses. As a result, it shows promise as an adjunctive tool to renal biopsy for clinical decision-making. Further assessment of Re-VASC’s true efficacy as a diagnostic marker will include prospective evaluation of a larger multicenter population.
- 29 January 2024
- Published by SAGE Publications in Journal of Endourology
- Vol. 38 (3) , 301-305
Utilization of Re-VASC, the Novel Retroperitoneal Neovascularity Scoring System, for Characterization of T1a Small Renal Masses
Purpose: Early characterization of small (T1a, < 4 cm) renal masses is imperative for patient care and treatment planning. Renal biopsy is a sensitive and specific procedure that can accurately differentiate small renal masses as malignant or benign. However, it is an invasive procedure with a non-negligible complication rate and is not performed routinely at most institutions. In this study, we sought to apply the Re-VASC scoring system to T1a renal masses and analyzed whether it could differentiate these masses as benign or malignant. Methods: We obtained Institutional Review Board approval to retrospectively examine the records of all patients who presented to our single, urban academic referral center for surgical treatment of renal cell carcinoma (RCC). For the malignant group, patients with a diagnosis of T1a RCC from pathologic evaluation were included. Additionally, patients with a histopathological diagnosis of a T1a non-malignant renal mass (fat poor-angiomyolipoma or oncocytoma) were included in our benign group. Results: This study includes 57 benign and 69 malignant T1a renal tumors. Average size for benign and malignant masses were 2.47 and 2.63 respectively (p=0.267). Analysis demonstrated no significant difference between both groups in terms of sex, laterality, or size. The average Re-VASC score of benign and malignant masses was 0.175 and malignant masses was 0.784 respectively (p<0.001). Additionally, the Re-VASC score was independently associated with malignancy with an odds ratio of 2.223 (p=0.0109). Conclusion: The Re-VASC scoring system exhibits significantly greater values for malignant T1a renal masses when compared to benign masses. As a result, it shows promise as an adjunctive tool to renal biopsy for clinical decision-making. Further assessment of Re-VASC’s true efficacy as a diagnostic marker will include prospective evaluation of a larger multicenter population.
- 1 December 2023
- Published by SAGE Publications in Journal of Endourology
- Vol. 37 (12) , 1289-1294
The Impact of Bilateral Stone Disease on Patients' Disease Progression and Health-Related Quality of Life
Purpose Patients with recurring kidney stone events can expect significant morbidity and functional impairment. Few studies have evaluated the effect of bilateral kidney stones on disease progression and quality of life. We wanted to determine the association of bilateral stone disease on age of onset, and the impact on number of stone events and individual kidney stone disease specific Health Related Quality of Life (HRQOL) by analysing the validated and prospectively collected Wisconsin Stone Quality of Life (WISQOL) database. Material and Methods We studied 2,906 stone patients from 16 centers in North America after having completed the WISQOL questionnaire from 2014 to 2019. Kidney stone formers were assessed if kidney stones were bilateral or unilateral on imaging. Analysis with a Chi-square test compared categorical variables. Bilateral kidney stone disease and its impact on HRQOL was evaluated through a multivariable linear regression model. Results Of 2,906 kidney stone formers, 1,340 had unilateral kidney stones and 1,566 had bilateral kidney stones. We observed more frequently that patients with bilateral stones had an increased number of depression/anxiety symptoms, renal tubular acidosis, and rheumatoid arthritis (all p<0.05). Patients with bilateral stones had a younger mean (SD) age of kidney stone disease onset (37.2±15.8 vs 46.4±15.9 years of age, p<0.001). Bilateral kidney stone formers had a higher mean (SD) number of stone events (11.3±21.8) than unilateral kidney stone formers (3.0±5.1) (p<0.001). Within our multivariable analysis, we found that HRQOL was negatively affected by the presence of bilateral stones for kidney stone patients (β=-11.2 (CI:-19.5 - -3.0) points, p<0.05). Conclusion Bilateral kidney stone formers had a younger age of kidney stone disease onset and a higher number of stone events compared to unilateral kidney stone disease formers. Presence of bilateral kidney stone disease negatively impacted HRQOL.
- 1 December 2023
- Published by SAGE Publications in Journal of Endourology
- Vol. 37 (12) , 1289-1294
The Impact of Bilateral Stone Disease on Patients' Disease Progression and Health-Related Quality of Life
Purpose Patients with recurring kidney stone events can expect significant morbidity and functional impairment. Few studies have evaluated the effect of bilateral kidney stones on disease progression and quality of life. We wanted to determine the association of bilateral stone disease on age of onset, and the impact on number of stone events and individual kidney stone disease specific Health Related Quality of Life (HRQOL) by analysing the validated and prospectively collected Wisconsin Stone Quality of Life (WISQOL) database. Material and Methods We studied 2,906 stone patients from 16 centers in North America after having completed the WISQOL questionnaire from 2014 to 2019. Kidney stone formers were assessed if kidney stones were bilateral or unilateral on imaging. Analysis with a Chi-square test compared categorical variables. Bilateral kidney stone disease and its impact on HRQOL was evaluated through a multivariable linear regression model. Results Of 2,906 kidney stone formers, 1,340 had unilateral kidney stones and 1,566 had bilateral kidney stones. We observed more frequently that patients with bilateral stones had an increased number of depression/anxiety symptoms, renal tubular acidosis, and rheumatoid arthritis (all p<0.05). Patients with bilateral stones had a younger mean (SD) age of kidney stone disease onset (37.2±15.8 vs 46.4±15.9 years of age, p<0.001). Bilateral kidney stone formers had a higher mean (SD) number of stone events (11.3±21.8) than unilateral kidney stone formers (3.0±5.1) (p<0.001). Within our multivariable analysis, we found that HRQOL was negatively affected by the presence of bilateral stones for kidney stone patients (β=-11.2 (CI:-19.5 - -3.0) points, p<0.05). Conclusion Bilateral kidney stone formers had a younger age of kidney stone disease onset and a higher number of stone events compared to unilateral kidney stone disease formers. Presence of bilateral kidney stone disease negatively impacted HRQOL.
- 1 November 2021
- Published by SAGE Publications in Journal of Endourology
- Vol. 35 (11) , 1684-1692
Global Assessments of the Endockscope System: Long-Term Impact of Cyber Endoscopy
Introduction: The disproportionate costs of state-of-the-art endoscopic equipment prohibit urologists from performing endoscopy in underserved countries. Given the global prevalence of smartphones, we engineered a $45 alternative endoscope utilizing three-dimensional printed attachments, an 8 × lens, and a 1000-lumen light-emitting diode cordless flashlight (Endockscope System [ES]). Materials and Methods: At the 34th World Congress of Endourology in Cape Town, South Africa (WCE 2016; 4-year group), and at the 39th Congress of the Société Internationale d'Urologie (SIU) in Athens, Greece (SIU 2019; 8-month group), a total of 40 ES kits were distributed free of charge to an international group of urologists. Participants were given instructions and a hands-on demonstration of the device. Urologists given an ES were subsequently asked to complete a survey between June and September 2020 that included questions regarding user satisfaction, comfort, and comparability of the ES to standard endoscopic systems. Results: Urologists from 23 countries received ES kits. Overall, 10 of 22 urologists (10/22; 45%) from the 4-year group and 18 of 18 urologists (18/18; 100%) from the 8-month group completed the survey. The ES device was used by 80% (8/10) and 83% (15/18) of urologists from the 4-year and the 8-month groups, respectively. Of note, the greatest impact of ES usage was among urologists from the most impoverished countries. Of those who used the ES, 44% (4/9) of urologists from the 4-year cohort and 47% (8/17) from the 8-month cohort reported they were able to perform more endoscopic procedures directly because of the ES. Moreover, 57% (4/7) of the 4-year participants and 67% (10/15) of the 8-month participants found the ES equal or superior in quality to their standard endoscopic equipment. Conclusion: The ES provided an effective and inexpensive system that enabled urologists in resource-challenged countries to effectively perform and expand their use of urologic endoscopy.
- 1 November 2021
- Published by SAGE Publications in Journal of Endourology
- Vol. 35 (11) , 1684-1692
Global Assessments of the Endockscope System: Long-Term Impact of Cyber Endoscopy
Introduction: The disproportionate costs of state-of-the-art endoscopic equipment prohibit urologists from performing endoscopy in underserved countries. Given the global prevalence of smartphones, we engineered a $45 alternative endoscope utilizing three-dimensional printed attachments, an 8 × lens, and a 1000-lumen light-emitting diode cordless flashlight (Endockscope System [ES]). Materials and Methods: At the 34th World Congress of Endourology in Cape Town, South Africa (WCE 2016; 4-year group), and at the 39th Congress of the Société Internationale d'Urologie (SIU) in Athens, Greece (SIU 2019; 8-month group), a total of 40 ES kits were distributed free of charge to an international group of urologists. Participants were given instructions and a hands-on demonstration of the device. Urologists given an ES were subsequently asked to complete a survey between June and September 2020 that included questions regarding user satisfaction, comfort, and comparability of the ES to standard endoscopic systems. Results: Urologists from 23 countries received ES kits. Overall, 10 of 22 urologists (10/22; 45%) from the 4-year group and 18 of 18 urologists (18/18; 100%) from the 8-month group completed the survey. The ES device was used by 80% (8/10) and 83% (15/18) of urologists from the 4-year and the 8-month groups, respectively. Of note, the greatest impact of ES usage was among urologists from the most impoverished countries. Of those who used the ES, 44% (4/9) of urologists from the 4-year cohort and 47% (8/17) from the 8-month cohort reported they were able to perform more endoscopic procedures directly because of the ES. Moreover, 57% (4/7) of the 4-year participants and 67% (10/15) of the 8-month participants found the ES equal or superior in quality to their standard endoscopic equipment. Conclusion: The ES provided an effective and inexpensive system that enabled urologists in resource-challenged countries to effectively perform and expand their use of urologic endoscopy.
- 1 November 2021
- Published by SAGE Publications in Journal of Endourology
- Vol. 35 (11) , 1716-1722
Caveat Emptor: The Heat Is “ON”—An In Vivo Evaluation of the Thulium Fiber Laser and Temperature Changes in the Porcine Kidney During Dusting and Fragmentation Modes
Introduction: We sought to examine the intrarenal fluid and tissue temperature alterations during dusting and fragmentation with the thulium fiber laser (TFL) in an in vivo porcine kidney. Materials and Methods: In two female Yorkshire pigs, temperature was continuously measured within the upper, interpolar, and lower calices along with the renal pelvis using multipoint thermal sensor probes; another temperature probe was situated at the tip of the ureteroscope. Four experimental protocols were performed for each animal: dual lumen ureteroscope with both warmed (37°C) irrigation and room temperature (20°C–22°C) irrigation and single lumen ureteroscope with warmed and room temperature irrigation. Of note, in each pig, one kidney underwent ureteroscopy (URS) with a 14F ureteral access sheath (UAS) in place, whereas the other kidney had no UAS placed. A 200-μm TFL fiber was fired at three laser settings: (1) dusting at 0.5 J, 80 Hz (40 W) with continuous activation until 5 minutes expired or a temperature of 44°C was reached, (2) low-power fragmentation 1 J, 10 Hz, (10 W), and (3) high-power fragmentation at 1.5 J, 20 Hz (30 W). In all cases, the pulse width was 1 ms. For fragmentation, the laser was activated for 10 seconds with a 2-second intermission for a 1-minute period (five cycles). Results: In the absence of a UAS, in all but one circumstance, temperatures reached or exceeded 44°C at all laser settings with the use of either warm or room temperature irrigation fluid, regardless of the type of ureteroscope used. Of concern, temperatures recorded at the tip of the URS were 4°C to 22°C less than the temperatures recorded in the renal calices. In contrast, with a 14F UAS in place, six distinct groups had temperatures that did not exceed 44°C, specifically at low- and high-power fragmentation settings with room temperature irrigation for both sets of ureteroscopes and at dusting and low-power fragmentation settings with warm temperature irrigation solely for the single lumen ureteroscope. Temperatures recorded at the tip of the ureteroscope with the deployment of a UAS yielded temperature differences ranging from 17°C less to 19°C more than the renal calices. Conclusions: TFL is a novel laser technology for lithotripsy. In the absence of a UAS, high-power TFL fragmentation settings in particular may create temperatures within the collecting system that could result in urothelial tissue injury. Of note, peak temperatures recorded at the tip of the ureteroscope may misrepresent the actual intrarenal temperature during TFL laser lithotripsy.
- 1 November 2021
- Published by SAGE Publications in Journal of Endourology
- Vol. 35 (11) , 1716-1722
Caveat Emptor: The Heat Is “ON”—An In Vivo Evaluation of the Thulium Fiber Laser and Temperature Changes in the Porcine Kidney During Dusting and Fragmentation Modes
Introduction: We sought to examine the intrarenal fluid and tissue temperature alterations during dusting and fragmentation with the thulium fiber laser (TFL) in an in vivo porcine kidney. Materials and Methods: In two female Yorkshire pigs, temperature was continuously measured within the upper, interpolar, and lower calices along with the renal pelvis using multipoint thermal sensor probes; another temperature probe was situated at the tip of the ureteroscope. Four experimental protocols were performed for each animal: dual lumen ureteroscope with both warmed (37°C) irrigation and room temperature (20°C–22°C) irrigation and single lumen ureteroscope with warmed and room temperature irrigation. Of note, in each pig, one kidney underwent ureteroscopy (URS) with a 14F ureteral access sheath (UAS) in place, whereas the other kidney had no UAS placed. A 200-μm TFL fiber was fired at three laser settings: (1) dusting at 0.5 J, 80 Hz (40 W) with continuous activation until 5 minutes expired or a temperature of 44°C was reached, (2) low-power fragmentation 1 J, 10 Hz, (10 W), and (3) high-power fragmentation at 1.5 J, 20 Hz (30 W). In all cases, the pulse width was 1 ms. For fragmentation, the laser was activated for 10 seconds with a 2-second intermission for a 1-minute period (five cycles). Results: In the absence of a UAS, in all but one circumstance, temperatures reached or exceeded 44°C at all laser settings with the use of either warm or room temperature irrigation fluid, regardless of the type of ureteroscope used. Of concern, temperatures recorded at the tip of the URS were 4°C to 22°C less than the temperatures recorded in the renal calices. In contrast, with a 14F UAS in place, six distinct groups had temperatures that did not exceed 44°C, specifically at low- and high-power fragmentation settings with room temperature irrigation for both sets of ureteroscopes and at dusting and low-power fragmentation settings with warm temperature irrigation solely for the single lumen ureteroscope. Temperatures recorded at the tip of the ureteroscope with the deployment of a UAS yielded temperature differences ranging from 17°C less to 19°C more than the renal calices. Conclusions: TFL is a novel laser technology for lithotripsy. In the absence of a UAS, high-power TFL fragmentation settings in particular may create temperatures within the collecting system that could result in urothelial tissue injury. Of note, peak temperatures recorded at the tip of the ureteroscope may misrepresent the actual intrarenal temperature during TFL laser lithotripsy.
- 1 October 2021
- Published by Elsevier in Urologic Oncology: Seminars and Original Investigations
- Vol. 39 (10) , 735.e17-735.e23
Can preoperative renal mass biopsy change clinical practice and reduce surgical intervention for small renal masses?
- 1 October 2021
- Published by Elsevier in Urologic Oncology: Seminars and Original Investigations
- Vol. 39 (10) , 735.e17-735.e23
Can preoperative renal mass biopsy change clinical practice and reduce surgical intervention for small renal masses?
- 1 August 2021
- Published by SAGE Publications in Journal of Endourology
- Vol. 35 (8) , 1236-1243
Analysis of Ureteral Diameter and Peristalsis in Response to Irrigant Fluid Temperature Changes in an In Vivo Porcine Model
Objective: It has been previously reported that warming irrigation fluid higher than body temperature may decrease ureteral spasm and thereby facilitate ureteroscopic access to the proximal ureter. Our objective was to examine the effects on ureteral peristalsis and ureteral diameter if the irrigant was warmed to just under the biological threshold for injury. Materials and Methods: Two female adult Yorkshire pigs were studied in this pilot study. In the first pig, a dilute mixture of contrast and irrigation fluid at 37°C and then at 43°C was instilled for 30 minutes into each renal pelvis through a ureteral catheter at 40 mm Hg. Retrograde pyelogram images were captured for each trial and the caliber of the ureter was measured using Vitrea ® software. In the second pig, a lumbotomy was performed, and a magnetic sensor was placed on the extraluminal surface of the ureter to monitor ureteral peristalsis while repeating the aforedescribed regimen. Thirty minutes after the first regimen, the force exerted during placement of a 16F ureteral access sheath (UAS) was recorded at both temperatures using the University of California, Irvine Ureteral Force Sensor. Results: There was no statistically significant difference in ureteral caliber along the length of the ureter at 43°C ( p = 0.87, p = 0.32, p = 0.66 for proximal, middle, and distal ureter, respectively). Indeed, there was an increase in peristalsis from baseline with fluid irrigation at 37°C and at 43°C (59% and 65%, respectively). There was no significant difference in the force exerted for UAS placement at either temperature. On histologic analysis, there were no significant changes in ureteral histology or luminal diameter. Conclusions: In a porcine model, warming irrigation fluid to just under the biological threshold for injury did not increase ureteral caliber, decrease ureteral peristalsis, or facilitate UAS placement. As such, during ureteroscopy, we continue to warm our irrigation fluid just to body temperature.
- 1 August 2021
- Published by SAGE Publications in Journal of Endourology
- Vol. 35 (8) , 1236-1243
Analysis of Ureteral Diameter and Peristalsis in Response to Irrigant Fluid Temperature Changes in an In Vivo Porcine Model
Objective: It has been previously reported that warming irrigation fluid higher than body temperature may decrease ureteral spasm and thereby facilitate ureteroscopic access to the proximal ureter. Our objective was to examine the effects on ureteral peristalsis and ureteral diameter if the irrigant was warmed to just under the biological threshold for injury. Materials and Methods: Two female adult Yorkshire pigs were studied in this pilot study. In the first pig, a dilute mixture of contrast and irrigation fluid at 37°C and then at 43°C was instilled for 30 minutes into each renal pelvis through a ureteral catheter at 40 mm Hg. Retrograde pyelogram images were captured for each trial and the caliber of the ureter was measured using Vitrea ® software. In the second pig, a lumbotomy was performed, and a magnetic sensor was placed on the extraluminal surface of the ureter to monitor ureteral peristalsis while repeating the aforedescribed regimen. Thirty minutes after the first regimen, the force exerted during placement of a 16F ureteral access sheath (UAS) was recorded at both temperatures using the University of California, Irvine Ureteral Force Sensor. Results: There was no statistically significant difference in ureteral caliber along the length of the ureter at 43°C ( p = 0.87, p = 0.32, p = 0.66 for proximal, middle, and distal ureter, respectively). Indeed, there was an increase in peristalsis from baseline with fluid irrigation at 37°C and at 43°C (59% and 65%, respectively). There was no significant difference in the force exerted for UAS placement at either temperature. On histologic analysis, there were no significant changes in ureteral histology or luminal diameter. Conclusions: In a porcine model, warming irrigation fluid to just under the biological threshold for injury did not increase ureteral caliber, decrease ureteral peristalsis, or facilitate UAS placement. As such, during ureteroscopy, we continue to warm our irrigation fluid just to body temperature.
- 1 February 2021
- Published by SAGE Publications in Journal of Endourology
- Vol. 35 (2) , 187-191
In Vitro Evaluation of Stone Fragment Evacuation by Suction
Introduction: Contemporary, flexible stone baskets are unable to extract submillimeter stone fragments at the time of ureteroscopic laser lithotripsy. In this in vitro study, the feasibility of suctioning submillimeter fragments with a standard Luer Lock syringe through the working channel of a flexible ureteroscope was assessed. Materials and Methods: Phantom stones made from industrial plaster were mechanically fragmented into ≤1 and ≤0.5-mm groups. Both stone groups were divided into five preweighed trial samples. Each stone group was then mixed in a beaker filled with normal saline. A standard 10-mL Luer Lock syringe was connected to a fiber-optic ureteroscope with a 1.2-mm working channel. The syringe was then used to suction stone fragments from the beaker. The suctioned stone fragments and the stone fragments remaining in the beaker after removing the overlying solution were separated, centrifuged with supernatant removed, and dried in an incubator set at 33°C for 1 week. Dried weights were recorded. Results: Mean total weights for ≤0.5 and ≤1.0-mm stone groups at baseline were 0.807 and 0.806 g, respectively. The mean percentages of stone fragments suctioned through the ureteroscope for ≤0.5 and ≤1.0-mm groups were 86% and 86%, respectively ( p = 0.973). During suctioning, 64% of stones in the ≤0.5-mm group were trapped in either the working channel of the ureteroscope or within the Luer Lock syringe compared with 78% of stones in the ≤1-mm group ( p = 0.001) requiring cessation of the procedure to clear the channel. Conclusions: It is feasible to suction submillimeter stone fragments by connecting a Luer Lock syringe to the working channel of a flexible ureteroscope. The limiting factor for removing stone fragments appears to be the small working channel of flexible ureteroscopes as trapping of fragments during suctioning is common and requires time-consuming removal of the endoscope and clearing of the channel.
- 1 February 2021
- Published by SAGE Publications in Journal of Endourology
- Vol. 35 (2) , 187-191
In Vitro Evaluation of Stone Fragment Evacuation by Suction
Introduction: Contemporary, flexible stone baskets are unable to extract submillimeter stone fragments at the time of ureteroscopic laser lithotripsy. In this in vitro study, the feasibility of suctioning submillimeter fragments with a standard Luer Lock syringe through the working channel of a flexible ureteroscope was assessed. Materials and Methods: Phantom stones made from industrial plaster were mechanically fragmented into ≤1 and ≤0.5-mm groups. Both stone groups were divided into five preweighed trial samples. Each stone group was then mixed in a beaker filled with normal saline. A standard 10-mL Luer Lock syringe was connected to a fiber-optic ureteroscope with a 1.2-mm working channel. The syringe was then used to suction stone fragments from the beaker. The suctioned stone fragments and the stone fragments remaining in the beaker after removing the overlying solution were separated, centrifuged with supernatant removed, and dried in an incubator set at 33°C for 1 week. Dried weights were recorded. Results: Mean total weights for ≤0.5 and ≤1.0-mm stone groups at baseline were 0.807 and 0.806 g, respectively. The mean percentages of stone fragments suctioned through the ureteroscope for ≤0.5 and ≤1.0-mm groups were 86% and 86%, respectively ( p = 0.973). During suctioning, 64% of stones in the ≤0.5-mm group were trapped in either the working channel of the ureteroscope or within the Luer Lock syringe compared with 78% of stones in the ≤1-mm group ( p = 0.001) requiring cessation of the procedure to clear the channel. Conclusions: It is feasible to suction submillimeter stone fragments by connecting a Luer Lock syringe to the working channel of a flexible ureteroscope. The limiting factor for removing stone fragments appears to be the small working channel of flexible ureteroscopes as trapping of fragments during suctioning is common and requires time-consuming removal of the endoscope and clearing of the channel.