Comparison of the Diagnostic Utility of 4D-DSA with Conventional 2D- and 3D-DSA in the Diagnosis of Cerebrovascular Abnormalities
Open Access
- 9 March 2017
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 38 (4) , 729-734
Abstract
BACKGROUND AND PURPOSE: 4D-DSA is a time-resolved technique that allows viewing of a contrast bolus at any time and from any desired viewing angle. Our hypothesis was that the information content in a 4D-DSA reconstruction was essentially equivalent to that in a combination of 2D acquisitions and a 3D-DSA reconstruction. MATERIALS AND METHODS: Twenty-six consecutive patients who had both 2D- and 3D-DSA acquisitions were included in the study. The angiography report was used to obtain diagnoses and characteristics of abnormalities. Diagnoses included AVM/AVFs, aneurysms, stenosis, and healthy individuals. 4D-DSA reconstructions were independently reviewed by 3 experienced observers who had no part in the clinical care. Using an electronic evaluation form, these observers recorded their assessments based only on the 4D reconstructions. The clinical evaluations were then compared with the 4D evaluations for diagnosis and lesion characteristics. RESULTS: Results showed both interrater and interclass agreements (κ = 0.813 and 0.858). Comparing the 4D diagnosis with the clinical diagnosis for the 3 observers yielded κ values of 0.906, 0.912, and 0.906. The κ values for agreement among the 3 observers for the type of abnormality were 0.949, 0.845, and 0.895. There was complete agreement on the presence of an abnormality between the clinical and 4D-DSA in 23/26 cases. In 2 cases, there were conflicting opinions. CONCLUSIONS: In this study, the information content of 4D-DSA reconstructions was largely equivalent to that of the combined 2D/3D studies. The availability of 4D-DSA should reduce the requirement for 2D-DSA acquisitions.Keywords
This publication has 9 references indexed in Scilit:
- Application of 4-Dimensional Digital Subtraction Angiography for Dural Arteriovenous FistulasWorld Neurosurgery, 2016
- Time-resolved 3D rotational angiography: display of detailed neurovascular anatomy in patients with intracranial vascular malformationsJournal of NeuroInterventional Surgery, 2016
- A Comparison of 4D DSA with 2D and 3D DSA in the Analysis of Normal Vascular Structures in a Canine ModelAmerican Journal of Neuroradiology, 2015
- 4D DSA a new technique for arteriovenous malformation evaluation: a feasibility studyJournal of NeuroInterventional Surgery, 2015
- 4D Digital Subtraction Angiography: Implementation and Demonstration of FeasibilityAmerican Journal of Neuroradiology, 2013
- Benefits of 3D Rotational DSA Compared with 2D DSA in the Evaluation of Intracranial AneurysmAcademic Radiology, 2012
- Research electronic data capture (REDCap)—A metadata-driven methodology and workflow process for providing translational research informatics supportJournal of Biomedical Informatics, 2009
- Intraclass correlations: Uses in assessing rater reliability.Psychological Bulletin, 1979
- Measuring nominal scale agreement among many raters.Psychological Bulletin, 1971