Sebastian Schafer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sebastian Schafer has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Charles M. Strother
Univ. of Wisconsin-Madison (United States)
7 shared publications - Michael A. Speidel
Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin; Department of Medicine, University of Wisconsin-Madison, Madison, Wisconsin
5 shared publications - Azam S. Ahmed
Department of Neurological Surgery, University of Wisconsin School of Medicine, Madison, Wisconsin, USA
3 shared publications - Katrina L. Ruedinger
From the School of Medicine and Public Health (K.L.R.)
3 shared publications - Kevin Royalty
Siemens Medical Solutions, USA, Inc., Hoffman Estates, USA
3 shared publications - Pengfei Yang
Neurovascular Center, Changhai Hospital, Naval Medical University, Shanghai, China
3 shared publications
Latest Publications
- 1 November 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 11 (06) , 1-13
Comparison of sequential multi-detector CT and cone-beam CT perfusion maps in 39 subjects with anterior circulation acute ischemic stroke due to a large vessel occlusion
PurposeThe critical time between stroke onset and treatment was targeted for reduction by integrating physiological imaging into the angiography suite, potentially improving clinical outcomes. The evaluation was conducted to compare C-Arm cone beam CT perfusion (CBCTP) with multi-detector CT perfusion (MDCTP) in patients with acute ischemic stroke (AIS).ApproachThirty-nine patients with anterior circulation AIS underwent both MDCTP and CBCTP. Imaging results were compared using an in-house algorithm for CBCTP map generation and RAPID for post-processing. Blinded neuroradiologists assessed images for quality, diagnostic utility, and treatment decision support, with non-inferiority analysis (two one-sided tests for equivalence) and inter-reviewer consistency (Cohen’s kappa).ResultsThe mean time from MDCTP to angiography suite arrival was 50±34 min, and that from arrival to the first CBCTP image was 21±8 min. Stroke diagnosis accuracies were 96% [93%, 97%] with MDCTP and 91% [90%, 93%] with CBCTP. Cohen’s kappa between observers was 0.86 for MDCTP and 0.90 for CBCTP, showing excellent inter-reader consistency. CBCTP’s scores for diagnostic utility, mismatch pattern detection, and treatment decisions were noninferior to MDCTP scores (alpha = 0.05) within 20% of the range. MDCTP was slightly superior for image quality and artifact score (1.8 versus 2.3, p<0.01).ConclusionsIn this small paper, CBCTP was noninferior to MDCTP, potentially saving nearly an hour per patient if they went directly to the angiography suite upon hospital arrival.
- 1 November 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 11 (06) , 1-13
Comparison of sequential multi-detector CT and cone-beam CT perfusion maps in 39 subjects with anterior circulation acute ischemic stroke due to a large vessel occlusion
PurposeThe critical time between stroke onset and treatment was targeted for reduction by integrating physiological imaging into the angiography suite, potentially improving clinical outcomes. The evaluation was conducted to compare C-Arm cone beam CT perfusion (CBCTP) with multi-detector CT perfusion (MDCTP) in patients with acute ischemic stroke (AIS).ApproachThirty-nine patients with anterior circulation AIS underwent both MDCTP and CBCTP. Imaging results were compared using an in-house algorithm for CBCTP map generation and RAPID for post-processing. Blinded neuroradiologists assessed images for quality, diagnostic utility, and treatment decision support, with non-inferiority analysis (two one-sided tests for equivalence) and inter-reviewer consistency (Cohen’s kappa).ResultsThe mean time from MDCTP to angiography suite arrival was 50±34 min, and that from arrival to the first CBCTP image was 21±8 min. Stroke diagnosis accuracies were 96% [93%, 97%] with MDCTP and 91% [90%, 93%] with CBCTP. Cohen’s kappa between observers was 0.86 for MDCTP and 0.90 for CBCTP, showing excellent inter-reader consistency. CBCTP’s scores for diagnostic utility, mismatch pattern detection, and treatment decisions were noninferior to MDCTP scores (alpha = 0.05) within 20% of the range. MDCTP was slightly superior for image quality and artifact score (1.8 versus 2.3, p<0.01).ConclusionsIn this small paper, CBCTP was noninferior to MDCTP, potentially saving nearly an hour per patient if they went directly to the angiography suite upon hospital arrival.
- 15 October 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 8 (05) , 055001-14
Three-dimensional catheter navigation of airways using continuous-sweep limited angle fluoroscopy on a C-arm
Purpose: To develop an imaging-based 3D catheter navigation system for transbronchial procedures including biopsy and tumor ablation using a single-plane C-arm x-ray system. The proposed system provides time-resolved catheter shape and position as well as motion compensated 3D airway roadmaps. Approach: A continuous-sweep limited angle (CLA) imaging mode where the C-arm continuously rotates back and forth within a limited angular range while acquiring x-ray images was used for device tracking. The catheter reconstruction was performed using a sliding window of the most recent x-ray images, which captures information on device shape and position versus time. The catheter was reconstructed using a model-based approach and was displayed together with the 3D airway roadmap extracted from a pre-navigational cone-beam CT (CBCT). The roadmap was updated in regular intervals using deformable registration to tomosynthesis reconstructions based on the CLA images. The approach was evaluated in a porcine study (three animals) and compared to a gold standard CBCT reconstruction of the device. Results: The average 3D root mean squared distance between CLA and CBCT reconstruction of the catheter centerline was 1 ± 0.5 mm for a stationary catheter and 2.9 ± 1.1 mm for a catheter moving at ∼1 cm / s. The average tip localization error was 1.3 ± 0.7 mm and 2.7 ± 1.8 mm, respectively. Conclusions: The results indicate catheter navigation based on the proposed single plane C-arm imaging technique is feasible with reconstruction errors similar to the diameter of a typical ablation catheter.
- 15 October 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 8 (05) , 055001-14
Three-dimensional catheter navigation of airways using continuous-sweep limited angle fluoroscopy on a C-arm
Purpose: To develop an imaging-based 3D catheter navigation system for transbronchial procedures including biopsy and tumor ablation using a single-plane C-arm x-ray system. The proposed system provides time-resolved catheter shape and position as well as motion compensated 3D airway roadmaps. Approach: A continuous-sweep limited angle (CLA) imaging mode where the C-arm continuously rotates back and forth within a limited angular range while acquiring x-ray images was used for device tracking. The catheter reconstruction was performed using a sliding window of the most recent x-ray images, which captures information on device shape and position versus time. The catheter was reconstructed using a model-based approach and was displayed together with the 3D airway roadmap extracted from a pre-navigational cone-beam CT (CBCT). The roadmap was updated in regular intervals using deformable registration to tomosynthesis reconstructions based on the CLA images. The approach was evaluated in a porcine study (three animals) and compared to a gold standard CBCT reconstruction of the device. Results: The average 3D root mean squared distance between CLA and CBCT reconstruction of the catheter centerline was 1 ± 0.5 mm for a stationary catheter and 2.9 ± 1.1 mm for a catheter moving at ∼1 cm / s. The average tip localization error was 1.3 ± 0.7 mm and 2.7 ± 1.8 mm, respectively. Conclusions: The results indicate catheter navigation based on the proposed single plane C-arm imaging technique is feasible with reconstruction errors similar to the diameter of a typical ablation catheter.
- 26 November 2020
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 42 (2) , 214-220
4D-DSA: Development and Current Neurovascular Applications
SUMMARY: Originally described by Davis et al in 2013, 4D-Digital Subtraction Angiography (4D-DSA) has developed into a commercially available application of DSA in the angiography suite. 4D-DSA provides the user with 3D time-resolved images, allowing observation of a contrast bolus at any desired viewing angle through the vasculature and at any time point during the acquisition (any view at any time). 4D-DSA mitigates some limitations that are intrinsic to both 2D- and 3D-DSA images. The clinical applications for 4D-DSA include evaluations of AVMs and AVFs, intracranial aneurysms, and atherosclerotic occlusive disease. Recent advances in blood flow quantification using 4D-DSA indicate that these data provide both the velocity and geometric information necessary for the quantification of blood flow. In this review, we will discuss the development, acquisition, reconstruction, and current neurovascular applications of 4D-DSA volumes.
- 26 November 2020
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 42 (2) , 214-220
4D-DSA: Development and Current Neurovascular Applications
SUMMARY: Originally described by Davis et al in 2013, 4D-Digital Subtraction Angiography (4D-DSA) has developed into a commercially available application of DSA in the angiography suite. 4D-DSA provides the user with 3D time-resolved images, allowing observation of a contrast bolus at any desired viewing angle through the vasculature and at any time point during the acquisition (any view at any time). 4D-DSA mitigates some limitations that are intrinsic to both 2D- and 3D-DSA images. The clinical applications for 4D-DSA include evaluations of AVMs and AVFs, intracranial aneurysms, and atherosclerotic occlusive disease. Recent advances in blood flow quantification using 4D-DSA indicate that these data provide both the velocity and geometric information necessary for the quantification of blood flow. In this review, we will discuss the development, acquisition, reconstruction, and current neurovascular applications of 4D-DSA volumes.
- 31 October 2019
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 40 (12) , 2124-2129
Optimizing the Quality of 4D-DSA Temporal Information
BACKGROUND AND PURPOSE: Quantification of blood flow using a 4D-DSA would be useful in the diagnosis and treatment of cerebrovascular diseases. A protocol optimizing identification of density variations in the time-density curves of a 4D-DSA has not been defined. Our purpose was to determine the contrast injection protocol most likely to result in the optimal pulsatility signal strength. MATERIALS AND METHODS: Two 3D-printed patient-specific models were used and connected to a pulsatile pump and flow system, which delivered 250–260 mL/min to the model. Contrast medium (Isovue, 370 mg I/mL, 75% dilution) was injected through a 6F catheter positioned upstream from the inlet of the model. 4D-DSA acquisitions were performed for the following injection rates: 1.5, 2.0, 2.5, 3.0 and 3.5 mL/s for 8 seconds. To determine pulsatility, we analyzed the time-density curve at the inlets using the oscillation amplitude and a previously described numeric metric, the sideband ratio. Vascular geometry from 4D-DSA reconstructions was compared with ground truth and micro-CT measurements of the model. Dimensionless numbers that characterize hemodynamics, Reynolds and Craya-Curtet, were calculated for each injection rate. RESULTS: The strongest pulsatility signal occurred with the 2.5 mL/s injections. The largest oscillation amplitudes were found with 2.0- and 2.5-mL/s injections. Geometric accuracy was best preserved with injection rates of >1.5 mL/s. CONCLUSIONS: An injection rate of 2.5 mL/s provided the strongest pulsatility signal in the 4D-DSA time-density curve. Geometric accuracy was best preserved with injection rates above 1.5 mL/s. These results may be useful in future in vivo studies of blood flow quantification.
- 31 October 2019
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 40 (12) , 2124-2129
Optimizing the Quality of 4D-DSA Temporal Information
BACKGROUND AND PURPOSE: Quantification of blood flow using a 4D-DSA would be useful in the diagnosis and treatment of cerebrovascular diseases. A protocol optimizing identification of density variations in the time-density curves of a 4D-DSA has not been defined. Our purpose was to determine the contrast injection protocol most likely to result in the optimal pulsatility signal strength. MATERIALS AND METHODS: Two 3D-printed patient-specific models were used and connected to a pulsatile pump and flow system, which delivered 250–260 mL/min to the model. Contrast medium (Isovue, 370 mg I/mL, 75% dilution) was injected through a 6F catheter positioned upstream from the inlet of the model. 4D-DSA acquisitions were performed for the following injection rates: 1.5, 2.0, 2.5, 3.0 and 3.5 mL/s for 8 seconds. To determine pulsatility, we analyzed the time-density curve at the inlets using the oscillation amplitude and a previously described numeric metric, the sideband ratio. Vascular geometry from 4D-DSA reconstructions was compared with ground truth and micro-CT measurements of the model. Dimensionless numbers that characterize hemodynamics, Reynolds and Craya-Curtet, were calculated for each injection rate. RESULTS: The strongest pulsatility signal occurred with the 2.5 mL/s injections. The largest oscillation amplitudes were found with 2.0- and 2.5-mL/s injections. Geometric accuracy was best preserved with injection rates of >1.5 mL/s. CONCLUSIONS: An injection rate of 2.5 mL/s provided the strongest pulsatility signal in the 4D-DSA time-density curve. Geometric accuracy was best preserved with injection rates above 1.5 mL/s. These results may be useful in future in vivo studies of blood flow quantification.
- Open Access
- 13 September 2018
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 39 (10) , 1871-1877
Quantification of Blood Velocity with 4D Digital Subtraction Angiography Using the Shifted Least-Squares Method
BACKGROUND AND PURPOSE: 4D-DSA provides time-resolved 3D-DSA volumes with high temporal and spatial resolutions. The purpose of this study is to investigate a shifted least squares method to estimate the blood velocity from the 4D DSA images. Quantitative validation was performed using a flow phantom with an ultrasonic flow probe as ground truth. Quantification of blood velocity in human internal carotid arteries was compared with measurements generated from 3D phase-contrast MR imaging. MATERIALS AND METHODS: The centerlines of selected vascular segments and the time concentration curves of each voxel along the centerlines were determined from the 4D-DSA dataset. The temporal shift required to achieve a minimum difference between any point and other points along the centerline of a segment was calculated. The temporal shift as a function of centerline point position was fit to a straight line to generate the velocity. The proposed shifted least-squares method was first validated using a flow phantom study. Blood velocities were also estimated in the 14 ICAs of human subjects who had both 4D-DSA and phase-contrast MR imaging studies. Linear regression and correlation analysis were performed on both the phantom study and clinical study, respectively. RESULTS: Mean velocities of the flow phantom calculated from 4D-DSA matched very well with ultrasonic flow probe measurements with 11% relative root mean square error. Mean blood velocities of ICAs calculated from 4D-DSA correlated well with phase-contrast MR imaging measurements with Pearson correlation coefficient r = 0.835. CONCLUSIONS: The availability of 4D-DSA provides the opportunity to use the shifted least-squares method to estimate velocity in vessels within a 3D volume.
- 13 September 2018
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 39 (10) , 1871-1877
Open AccessQuantification of Blood Velocity with 4D Digital Subtraction Angiography Using the Shifted Least-Squares Method
BACKGROUND AND PURPOSE: 4D-DSA provides time-resolved 3D-DSA volumes with high temporal and spatial resolutions. The purpose of this study is to investigate a shifted least squares method to estimate the blood velocity from the 4D DSA images. Quantitative validation was performed using a flow phantom with an ultrasonic flow probe as ground truth. Quantification of blood velocity in human internal carotid arteries was compared with measurements generated from 3D phase-contrast MR imaging. MATERIALS AND METHODS: The centerlines of selected vascular segments and the time concentration curves of each voxel along the centerlines were determined from the 4D-DSA dataset. The temporal shift required to achieve a minimum difference between any point and other points along the centerline of a segment was calculated. The temporal shift as a function of centerline point position was fit to a straight line to generate the velocity. The proposed shifted least-squares method was first validated using a flow phantom study. Blood velocities were also estimated in the 14 ICAs of human subjects who had both 4D-DSA and phase-contrast MR imaging studies. Linear regression and correlation analysis were performed on both the phantom study and clinical study, respectively. RESULTS: Mean velocities of the flow phantom calculated from 4D-DSA matched very well with ultrasonic flow probe measurements with 11% relative root mean square error. Mean blood velocities of ICAs calculated from 4D-DSA correlated well with phase-contrast MR imaging measurements with Pearson correlation coefficient r = 0.835. CONCLUSIONS: The availability of 4D-DSA provides the opportunity to use the shifted least-squares method to estimate velocity in vessels within a 3D volume.
- 13 March 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10576, 105761A-37
A real-time system for prosthetic valve tracking
Transcatheter aortic valve replacement is a minimally invasive technique for the treatment of valvular heart disease, where an artificial valve mounted on a balloon catheter is guided to the aortic valve annulus. The balloon catheter is then expanded and displaces the diseased valve. We recently proposed an algorithm to track the 3D position, orientation and shape of a prosthetic transcatheter aortic valve using biplane fluoroscopic imaging. In this work, we present a real time hardware and software implementation of this prosthetic valve tracking method. A prototype was implemented which gathers fluoroscopic images from the angiography system via a research interface. A dynamic point cloud model of the valve is then used to estimate the 3D position, orientation and shape by minimizing a cost function. The cost function is implemented using parallel processing on graphics processing units to improve the performance. The system includes 3D rendering of the valve model and additional anatomy for visualization. The timing performance of the system was evaluated using a plastic cylinder phantom and a prosthetic valve mounted on a balloon catheter. The total computation time per frame for tracking and visualization using two different valve models was 46.11 ms and 43.88 ms respectively. This would allow frame rates of up to 21.69 frames per second. The target registration error of the estimated valve model was 1.22 ± 0.29 mm. Combined with 3D echocardiographic imaging, this technique would enable real time image guidance in 3D, where both the prosthetic valve and the soft tissue of the heart are visible.
- 13 March 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10576, 105761A-37
A real-time system for prosthetic valve tracking
Transcatheter aortic valve replacement is a minimally invasive technique for the treatment of valvular heart disease, where an artificial valve mounted on a balloon catheter is guided to the aortic valve annulus. The balloon catheter is then expanded and displaces the diseased valve. We recently proposed an algorithm to track the 3D position, orientation and shape of a prosthetic transcatheter aortic valve using biplane fluoroscopic imaging. In this work, we present a real time hardware and software implementation of this prosthetic valve tracking method. A prototype was implemented which gathers fluoroscopic images from the angiography system via a research interface. A dynamic point cloud model of the valve is then used to estimate the 3D position, orientation and shape by minimizing a cost function. The cost function is implemented using parallel processing on graphics processing units to improve the performance. The system includes 3D rendering of the valve model and additional anatomy for visualization. The timing performance of the system was evaluated using a plastic cylinder phantom and a prosthetic valve mounted on a balloon catheter. The total computation time per frame for tracking and visualization using two different valve models was 46.11 ms and 43.88 ms respectively. This would allow frame rates of up to 21.69 frames per second. The target registration error of the estimated valve model was 1.22 ± 0.29 mm. Combined with 3D echocardiographic imaging, this technique would enable real time image guidance in 3D, where both the prosthetic valve and the soft tissue of the heart are visible.
- Open Access
- 9 March 2017
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 38 (4) , 729-734
Comparison of the Diagnostic Utility of 4D-DSA with Conventional 2D- and 3D-DSA in the Diagnosis of Cerebrovascular Abnormalities
BACKGROUND AND PURPOSE: 4D-DSA is a time-resolved technique that allows viewing of a contrast bolus at any time and from any desired viewing angle. Our hypothesis was that the information content in a 4D-DSA reconstruction was essentially equivalent to that in a combination of 2D acquisitions and a 3D-DSA reconstruction. MATERIALS AND METHODS: Twenty-six consecutive patients who had both 2D- and 3D-DSA acquisitions were included in the study. The angiography report was used to obtain diagnoses and characteristics of abnormalities. Diagnoses included AVM/AVFs, aneurysms, stenosis, and healthy individuals. 4D-DSA reconstructions were independently reviewed by 3 experienced observers who had no part in the clinical care. Using an electronic evaluation form, these observers recorded their assessments based only on the 4D reconstructions. The clinical evaluations were then compared with the 4D evaluations for diagnosis and lesion characteristics. RESULTS: Results showed both interrater and interclass agreements (κ = 0.813 and 0.858). Comparing the 4D diagnosis with the clinical diagnosis for the 3 observers yielded κ values of 0.906, 0.912, and 0.906. The κ values for agreement among the 3 observers for the type of abnormality were 0.949, 0.845, and 0.895. There was complete agreement on the presence of an abnormality between the clinical and 4D-DSA in 23/26 cases. In 2 cases, there were conflicting opinions. CONCLUSIONS: In this study, the information content of 4D-DSA reconstructions was largely equivalent to that of the combined 2D/3D studies. The availability of 4D-DSA should reduce the requirement for 2D-DSA acquisitions.
- 9 March 2017
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 38 (4) , 729-734
Open AccessComparison of the Diagnostic Utility of 4D-DSA with Conventional 2D- and 3D-DSA in the Diagnosis of Cerebrovascular Abnormalities
BACKGROUND AND PURPOSE: 4D-DSA is a time-resolved technique that allows viewing of a contrast bolus at any time and from any desired viewing angle. Our hypothesis was that the information content in a 4D-DSA reconstruction was essentially equivalent to that in a combination of 2D acquisitions and a 3D-DSA reconstruction. MATERIALS AND METHODS: Twenty-six consecutive patients who had both 2D- and 3D-DSA acquisitions were included in the study. The angiography report was used to obtain diagnoses and characteristics of abnormalities. Diagnoses included AVM/AVFs, aneurysms, stenosis, and healthy individuals. 4D-DSA reconstructions were independently reviewed by 3 experienced observers who had no part in the clinical care. Using an electronic evaluation form, these observers recorded their assessments based only on the 4D reconstructions. The clinical evaluations were then compared with the 4D evaluations for diagnosis and lesion characteristics. RESULTS: Results showed both interrater and interclass agreements (κ = 0.813 and 0.858). Comparing the 4D diagnosis with the clinical diagnosis for the 3 observers yielded κ values of 0.906, 0.912, and 0.906. The κ values for agreement among the 3 observers for the type of abnormality were 0.949, 0.845, and 0.895. There was complete agreement on the presence of an abnormality between the clinical and 4D-DSA in 23/26 cases. In 2 cases, there were conflicting opinions. CONCLUSIONS: In this study, the information content of 4D-DSA reconstructions was largely equivalent to that of the combined 2D/3D studies. The availability of 4D-DSA should reduce the requirement for 2D-DSA acquisitions.
- 1 December 2016
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 37 (10) , 1646-1653
Flat-Panel CT for Cochlear Implant Electrode Imaging
Flat-panel computed tomography (FPCT) will allow more accurate localization of cochlear implants with decreased metallic artifact and decreased radiation dose when compared with multi-detector CT (MDCT). The measurement of scalar location and intra-scalar position of cochlear implantation (CI) electrodes using computed tomography (CT) is complicated by metallic image artifact and insufficient scalar resolution. FPCT has been shown to improve upon the resolution of MDCT while reducing artifact. Previous studies of FPCT imaging employed isolated temporal bones and did not compare FPCT with MDCT. A total of 11 CI electrodes (Flex-24, MED-EL Corp, Innsbruck, Austria) were intentionally placed into either the scala tympani (ST) or scala vestibule (SV) in whole cadaver heads and imaged with MDCT and FPCT. The relative radiation dose was measured at the ocular lens for each modality. The implanted cochleae were then isolated and imaged with micro-CT which was used to assess electrode position. Images were reviewed and scored according to electrode array scalar compartment (ST, SV, scala media [SM]), intra-scalar position within each compartment (perimodiolar, mid modiolor, lateral wall) and for the presence of artifact by five readers blinded to the imaging method and approach for electrode insertion. FPCT showed less metallic CI artifact (p = 0.002) and decreased radiation dosage when compared with MDCT. Reviewers were able to identify the scalar compartment and intra-scalar position of all electrodes more accurately with FPCT than with MDCT (p < 0.001). FPCT more accurately resolves the scalar compartment and intra-scalar position of CI electrodes with reduced radiation exposure and metallic artifact than MDCT.
- 1 December 2016
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 37 (10) , 1646-1653
Flat-Panel CT for Cochlear Implant Electrode Imaging
Flat-panel computed tomography (FPCT) will allow more accurate localization of cochlear implants with decreased metallic artifact and decreased radiation dose when compared with multi-detector CT (MDCT). The measurement of scalar location and intra-scalar position of cochlear implantation (CI) electrodes using computed tomography (CT) is complicated by metallic image artifact and insufficient scalar resolution. FPCT has been shown to improve upon the resolution of MDCT while reducing artifact. Previous studies of FPCT imaging employed isolated temporal bones and did not compare FPCT with MDCT. A total of 11 CI electrodes (Flex-24, MED-EL Corp, Innsbruck, Austria) were intentionally placed into either the scala tympani (ST) or scala vestibule (SV) in whole cadaver heads and imaged with MDCT and FPCT. The relative radiation dose was measured at the ocular lens for each modality. The implanted cochleae were then isolated and imaged with micro-CT which was used to assess electrode position. Images were reviewed and scored according to electrode array scalar compartment (ST, SV, scala media [SM]), intra-scalar position within each compartment (perimodiolar, mid modiolor, lateral wall) and for the presence of artifact by five readers blinded to the imaging method and approach for electrode insertion. FPCT showed less metallic CI artifact (p = 0.002) and decreased radiation dosage when compared with MDCT. Reviewers were able to identify the scalar compartment and intra-scalar position of all electrodes more accurately with FPCT than with MDCT (p < 0.001). FPCT more accurately resolves the scalar compartment and intra-scalar position of CI electrodes with reduced radiation exposure and metallic artifact than MDCT.
- Open Access
- 18 February 2016
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 37 (7) , 1303-1309
C-Arm Conebeam CT Perfusion Imaging in the Angiographic Suite: A Comparison with Multidetector CT Perfusion Imaging
BACKGROUND AND PURPOSE: Perfusion imaging in the angiography suite may provide a way to reduce time from stroke onset to endovascular revascularization of patients with large-vessel occlusion. Our purpose was to compare conebeam CT perfusion with multidetector CT perfusion. MATERIALS AND METHODS: Data from 7 subjects with both multidetector CT perfusion and conebeam CT perfusion were retrospectively processed and analyzed. Two algorithms were used to enhance temporal resolution and temporal sampling density and reduce the noise of conebeam CT data before generating perfusion maps. Two readers performed qualitative image-quality evaluation on maps by using a 5-point scale. ROIs indicating CBF/CBV abnormalities were drawn. Quantitative analyses were performed by using the Sørensen-Dice coefficients to quantify the similarity of abnormalities. A noninferiority hypothesis was tested to compare conebeam CT perfusion against multidetector CT perfusion. RESULTS: Average image-quality scores for multidetector CT perfusion and conebeam CT perfusion images were 2.4 and 2.3, respectively. The average confidence score in diagnosis was 1.4 for both multidetector CT and conebeam CT; the average confidence scores for the presence of a CBV/CBF mismatch were 1.7 (κ = 0.50) and 1.5 (κ = 0.64). For multidetector CT perfusion and conebeam CT perfusion maps, the average scores of confidence in making treatment decisions were 1.4 (κ = 0.79) and 1.3 (κ = 0.90). The area under the visual grading characteristic for the above 4 qualitative quality scores showed an average area under visual grading characteristic of 0.50, with 95% confidence level cover centered at the mean for both readers. The Sørensen–Dice coefficient for CBF maps was 0.81, and for CBV maps, 0.55. CONCLUSIONS: After postprocessing methods were applied to enhance image quality for conebeam CT perfusion maps, the conebeam CT perfusion maps were not inferior to those generated from multidetector CT perfusion.
- 18 February 2016
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 37 (7) , 1303-1309
Open AccessC-Arm Conebeam CT Perfusion Imaging in the Angiographic Suite: A Comparison with Multidetector CT Perfusion Imaging
BACKGROUND AND PURPOSE: Perfusion imaging in the angiography suite may provide a way to reduce time from stroke onset to endovascular revascularization of patients with large-vessel occlusion. Our purpose was to compare conebeam CT perfusion with multidetector CT perfusion. MATERIALS AND METHODS: Data from 7 subjects with both multidetector CT perfusion and conebeam CT perfusion were retrospectively processed and analyzed. Two algorithms were used to enhance temporal resolution and temporal sampling density and reduce the noise of conebeam CT data before generating perfusion maps. Two readers performed qualitative image-quality evaluation on maps by using a 5-point scale. ROIs indicating CBF/CBV abnormalities were drawn. Quantitative analyses were performed by using the Sørensen-Dice coefficients to quantify the similarity of abnormalities. A noninferiority hypothesis was tested to compare conebeam CT perfusion against multidetector CT perfusion. RESULTS: Average image-quality scores for multidetector CT perfusion and conebeam CT perfusion images were 2.4 and 2.3, respectively. The average confidence score in diagnosis was 1.4 for both multidetector CT and conebeam CT; the average confidence scores for the presence of a CBV/CBF mismatch were 1.7 (κ = 0.50) and 1.5 (κ = 0.64). For multidetector CT perfusion and conebeam CT perfusion maps, the average scores of confidence in making treatment decisions were 1.4 (κ = 0.79) and 1.3 (κ = 0.90). The area under the visual grading characteristic for the above 4 qualitative quality scores showed an average area under visual grading characteristic of 0.50, with 95% confidence level cover centered at the mean for both readers. The Sørensen–Dice coefficient for CBF maps was 0.81, and for CBV maps, 0.55. CONCLUSIONS: After postprocessing methods were applied to enhance image quality for conebeam CT perfusion maps, the conebeam CT perfusion maps were not inferior to those generated from multidetector CT perfusion.
- Open Access
- 22 October 2015
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 37 (4) , 648-654
Low-Dose Volume-of-Interest C-Arm CT Imaging of Intracranial Stents and Flow Diverters
BACKGROUND AND PURPOSE: Volume-of-interest C-arm CT is a novel technique for imaging of intracranial high-contrast objects. We performed this study to evaluate the potential diagnostic value and radiation dose reduction of this technique for imaging of intracranial stents and flow diverters. MATERIALS AND METHODS: Twenty-seven patients were imaged with a VOI C-arm CT scan following treatment with a flow diverter or stent-assisted coiling. The radiation dose-area product was recorded for VOI scans. For comparison, the dose-area product from 30 previously acquired consecutive full-view DynaCTs was used. Thermoluminescence dosimetry by using 35 evenly distributed thermoluminescence dosimeters in an anthropomorphic head phantom was also performed by using both conventional full field and VOI acquisitions. Three observers were presented with VOI images for assessment of the potential diagnostic value. RESULTS: The dose-area product measurements showed an exposure reduction of 85% compared with the full field acquisitions used for comparison. The thermoluminescence dosimetry evaluations also showed a considerable dose reduction of 79.8% throughout the volume. For most of the evaluated cases, the observers thought that diagnostically useful information was provided by the VOI images (α = .810). Visualization of device details, such as the extent of opening, positioning, wall apposition, and aneurysm coverage, was judged of good diagnostic quality for most cases (88.9%–92.6%). CONCLUSIONS: In this study, VOI C-arm CT provided high-quality diagnostic images of intracranial stents and flow diverters at a dramatic reduction of radiation exposure. Image content was thought to add useful information. It is a promising method to assess device status during procedures and at follow-up.
- 22 October 2015
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 37 (4) , 648-654
Open AccessLow-Dose Volume-of-Interest C-Arm CT Imaging of Intracranial Stents and Flow Diverters
BACKGROUND AND PURPOSE: Volume-of-interest C-arm CT is a novel technique for imaging of intracranial high-contrast objects. We performed this study to evaluate the potential diagnostic value and radiation dose reduction of this technique for imaging of intracranial stents and flow diverters. MATERIALS AND METHODS: Twenty-seven patients were imaged with a VOI C-arm CT scan following treatment with a flow diverter or stent-assisted coiling. The radiation dose-area product was recorded for VOI scans. For comparison, the dose-area product from 30 previously acquired consecutive full-view DynaCTs was used. Thermoluminescence dosimetry by using 35 evenly distributed thermoluminescence dosimeters in an anthropomorphic head phantom was also performed by using both conventional full field and VOI acquisitions. Three observers were presented with VOI images for assessment of the potential diagnostic value. RESULTS: The dose-area product measurements showed an exposure reduction of 85% compared with the full field acquisitions used for comparison. The thermoluminescence dosimetry evaluations also showed a considerable dose reduction of 79.8% throughout the volume. For most of the evaluated cases, the observers thought that diagnostically useful information was provided by the VOI images (α = .810). Visualization of device details, such as the extent of opening, positioning, wall apposition, and aneurysm coverage, was judged of good diagnostic quality for most cases (88.9%–92.6%). CONCLUSIONS: In this study, VOI C-arm CT provided high-quality diagnostic images of intracranial stents and flow diverters at a dramatic reduction of radiation exposure. Image content was thought to add useful information. It is a promising method to assess device status during procedures and at follow-up.