Plaque modification and stabilization after paclitaxel-coated balloon treatment for de novo coronary lesions
- 30 January 2019
- journal article
- research article
- Published by Springer Nature in Heart and Vessels
- Vol. 34 (7) , 1113-1121
Abstract
This study aimed to assess the healing response, as evidenced through temporal morphological and functional changes, following paclitaxel-coated balloon (PCB) treatment of de novo coronary lesions. This retrospective, observational study, included patients with significant de novo coronary lesions who were treated with PCB and had serial angiographic, intravascular ultrasound virtual histology (IVUS-VH), fractional flow reserve (FFR) measurements, and optical coherence tomography (OCT) performed before balloon angioplasty (BA), after BA, and at 9-month follow-up. A total of 20 patients (21 lesions) were included in this study. After PCB treatment, IVUS showed significant increases in the mean vessel area (12.0 ± 2.2 mm2 to 13.8 ± 2.5 mm2, p = 0.023), and mean lumen area (5.6 ± 1.2 mm2 to 7.0 ± 1.5 mm2, p = 0.003). Coronary flow was restored after BA with an FFR value of 0.87 ± 0.04 which was sustained at 9-month follow-up with no significant decrease (0.83 ± 0.08, p = 0.329). Serial OCT analysis showed that at 9-month follow-up dissections after BA sealed in 14 lesions (67%), whilst the macrophages decreased from 10 (50%) to 7 (35%) lesions, and the cap thickness of plaque increased from 0.12 ± 0.06 mm to 0.17 ± 0.09 mm (p = 0.007). PCB treatment for de novo coronary lesions showed persistent anatomical and functional patency at mid-term follow-up. Plaque modification, vascular remodeling, and plaque stabilization were also observed during follow-up.Keywords
This publication has 27 references indexed in Scilit:
- Drug-Coated Balloons for the Prevention of Vascular RestenosisCirculation, 2010
- The Dynamic Nature of Coronary Artery Lesion Morphology Assessed by Serial Virtual Histology Intravascular Ultrasound Tissue CharacterizationJACC, 2010
- Clinical End Points in Coronary Stent TrialsCirculation, 2007
- In Vivo Intravascular Ultrasound-Derived Thin-Cap Fibroatheroma Detection Using Ultrasound Radiofrequency Data AnalysisJACC, 2005
- Polymer-based paclitaxel-eluting stents reduce in-stent neointimal tissue proliferationJACC, 2005
- Paclitaxel Balloon Coating, a Novel Method for Prevention and Therapy of RestenosisCirculation, 2004
- Long-term assessment of a novel biodegradable paclitaxel-eluting coronary polylactide stentEuropean Heart Journal, 2004
- Response of very small (2 mm) porcine coronary arteries to balloon angioplasty and stent implantationHeart, 2004
- Vascular Responses at Proximal and Distal Edges of Paclitaxel-Eluting StentsCirculation, 2004
- Coronary Plaque Classification With Intravascular Ultrasound Radiofrequency Data AnalysisCirculation, 2002