Bi-component modeling of cerebrospinal fluid outflow using Time-SLIP MRI
Open Access
- 12 March 2026
- journal article
- research article
- Published by Springer Nature in Fluids and Barriers of the CNS
- Vol. 23 (1)
Abstract
Background: Understanding egress outflow of cerebrospinal fluid (CSF) is essential for exploring its role in brain health and its relationship to neurodegenerative diseases. Existing models often fail to capture the complex flow dynamics, particularly distinguishing rapid bulk flow from slower, perfusion-like components. This study aims to develop and validate a bi-component model that characterizes these distinct signal patterns using Time-Spatial Labeling Inversion Pulse (Time-SLIP) MRI data. Methods: A bi-component model is proposed by combining a Gaussian function (to represent fast bulk outflow) with a Г-variate function (representing slower, perfusion-like flow). Validation phantom studies were conducted using a sealed water phantom with computer-controlled bulk flow. In-vivo meninges images in eight healthy subjects were acquired on a clinical 3T MRI using Time-SLIP with 3D single-shot FSE. Signal Increase Ratio (SIR) from these experiments were fitted using the proposed bi-component model with fitting accuracy assessed using coefficient of determination (R 2 ), Sum of Squared estimate of Errors (SSE), and Root Mean Square Error (RMSE). Results: Phantom studies showed superior fitting of bulk fluid dynamics by the Gaussian component, confirmed by lower SSE, RMSE and higher R 2 . The in-vivo results demonstrated that the bi-component model provided a superior fit, capturing two distinct components of CSF outflow, which are hypothesized to correspond to fast bulk flow and a slower, perfusion-like component, which could be a mixture of CSF and interstitial fluid. Conclusion: The bi-component model enhances characterization of CSF egress outflow from intrinsic labeling by Time-SLIP, providing potential quantitative biomarkers for the assessment of neurodegenerative diseases.Keywords
This publication has 43 references indexed in Scilit:
- Clinical magnetic resonance imaging evaluation of glymphatic functionNMR in Biomedicine, 2024
- VICTR: Venous transit time imaging by changes in T1 relaxationMagnetic Resonance in Medicine, 2024
- Temperature dependence, accuracy, and repeatability of T1 and T2 relaxation times for the ISMRM/NIST system phantom measured using MR fingerprintingMagnetic Resonance in Medicine, 2021
- Black‐Blood Contrast in Cardiovascular MRIJournal of Magnetic Resonance Imaging, 2020
- The role of brain barriers in fluid movement in the CNS: is there a ‘glymphatic’ system?Acta Neuropathologica, 2018
- T 2 mapping of cerebrospinal fluid: 3 T versus 7 TMagnetic Resonance Materials in Physics, Biology and Medicine, 2017
- Impairment of paravascular clearance pathways in the aging brainAnnals of Neurology, 2014
- Oxygenation and hematocrit dependence of transverse relaxation rates of blood at 3TMagnetic Resonance in Medicine, 2007
- Determining the longitudinal relaxation time (T1) of blood at 3.0 TeslaMagnetic Resonance in Medicine, 2004
- Coronary Angiography with Magnetization‐Prepared T2 ContrastMagnetic Resonance in Medicine, 1995