Mitsue Miyazaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mitsue Miyazaki has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
Vadim Malis
Department of Radiology, University of California San Diego, San Diego, USA
8 shared publications- Won C. Bae
Department of Radiology, University of California-San Diego, La Jolla, CA 92093, USA
8 shared publications - Vadim Malis
Department of Radiology, University of California - San Diego, San Diego, USA
7 shared publications Asako Yamamoto
Department of Radiology, Teikyo University, Tokyo, Japan
6 shared publicationsDiana Vucevic
Department of Radiology, University of California San Diego, San Diego, CA, USA
5 shared publications- Vadim Malis
Department of Radiology, University of California-San Diego, La Jolla, CA 92093, USA
5 shared publications
Latest Publications
- Open Access
- 22 September 2026
- Published by Springer Nature in Scientific Reports
Phantom-based evaluation of time-SLIP MRI for measuring spinal-canal Lagrangian drift
The pulsatile motion of cerebrospinal fluid (CSF) in the spinal canal includes a mean Lagrangian drift, representing the cumulative net displacement experienced by the fluid over each oscillatory cycle. Quantifying this motion in vivo is challenging because the associated velocities ( $$\sim $$ cm min $$\vphantom{0}^{-1})$$ are much smaller than those of the dominant oscillatory flow ( $$\sim $$ cm s $$\vphantom{0}^{-1}$$ ), limiting the applicability of conventional phase-contrast (PC) MRI. Here we assess the suitability of Time-Spatial Labeling Inversion Pulse MRI (Time-SLIP) for characterizing this motion using in vitro experiments in a spinal-canal phantom. The phantom consists of a flexible tube with a rigid insert forming an eccentric annular canal representative of the spinal subarachnoid space, driven by a 1 Hz sinusoidal flow mimicking cardiac-induced CSF pulsations. Oscillatory velocities were measured with PC-MRI, while net fluid displacement over successive cycles was quantified using Time-SLIP and compared with numerical simulations. The measurements reveal spatially varying Lagrangian drift directed caudally in narrow regions and cranially in wider regions of the annulus, with magnitude scaling with the square of the local stroke volume. These results demonstrate that Time-SLIP can quantify mean Lagrangian motion associated with pulsatile CSF flow.- 22 September 2026
- Published by Springer Nature in Scientific Reports
Open AccessPhantom-based evaluation of time-SLIP MRI for measuring spinal-canal Lagrangian drift
The pulsatile motion of cerebrospinal fluid (CSF) in the spinal canal includes a mean Lagrangian drift, representing the cumulative net displacement experienced by the fluid over each oscillatory cycle. Quantifying this motion in vivo is challenging because the associated velocities ( $$\sim $$ cm min $$\vphantom{0}^{-1})$$ are much smaller than those of the dominant oscillatory flow ( $$\sim $$ cm s $$\vphantom{0}^{-1}$$ ), limiting the applicability of conventional phase-contrast (PC) MRI. Here we assess the suitability of Time-Spatial Labeling Inversion Pulse MRI (Time-SLIP) for characterizing this motion using in vitro experiments in a spinal-canal phantom. The phantom consists of a flexible tube with a rigid insert forming an eccentric annular canal representative of the spinal subarachnoid space, driven by a 1 Hz sinusoidal flow mimicking cardiac-induced CSF pulsations. Oscillatory velocities were measured with PC-MRI, while net fluid displacement over successive cycles was quantified using Time-SLIP and compared with numerical simulations. The measurements reveal spatially varying Lagrangian drift directed caudally in narrow regions and cranially in wider regions of the annulus, with magnitude scaling with the square of the local stroke volume. These results demonstrate that Time-SLIP can quantify mean Lagrangian motion associated with pulsatile CSF flow. - Open Access
- 1 June 2026
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 46 (9) , 2251-2260
Meningeal CSF transport varies across parasagittal dura subregions with age in humans
Cerebrospinal fluid (CSF) transport along meningeal pathways contributes to brain fluid homeostasis and is thought to change with aging, yet quantitative, region-resolved measurements across lifespan remain limited. We hypothesized that meningeal CSF transport dynamics exhibit region-specific age associations rather than uniform decline. We applied non-contrast time-spatial labeling inversion pulse (Time-SLIP) MRI combined with a bi-component analytical model to characterize CSF transport dynamics in a healthy, activity-controlled cohort of 64 adults aged 19–86 years. Signal increase ratio time courses were decomposed into a fast Gaussian bulk-displacement and a slower Γ-variate perfusion-like component. Linear mixed-effects models were used to assess regional and age-related effects. Model fits were robust across all participants ( R 2 = 0.97). CSF transport metrics differed significantly across parasagittal dura subregions and the superior sagittal sinus. Age associations were heterogeneous: the perfusion-like component declined with age in upper parasagittal dura, increased in lower parasagittal regions, and remained relatively stable within the superior sagittal sinus. Additional timing and amplitude parameters exhibited region-specific age trajectories. These findings demonstrate regionally heterogeneous aging effects on meningeal CSF transport dynamics and suggest age-related redistribution rather than uniform decline, providing a noninvasive framework for assessing physiological remodeling of CSF transport with aging.
- 1 June 2026
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 46 (9) , 2251-2260
Open AccessMeningeal CSF transport varies across parasagittal dura subregions with age in humans
Cerebrospinal fluid (CSF) transport along meningeal pathways contributes to brain fluid homeostasis and is thought to change with aging, yet quantitative, region-resolved measurements across lifespan remain limited. We hypothesized that meningeal CSF transport dynamics exhibit region-specific age associations rather than uniform decline. We applied non-contrast time-spatial labeling inversion pulse (Time-SLIP) MRI combined with a bi-component analytical model to characterize CSF transport dynamics in a healthy, activity-controlled cohort of 64 adults aged 19–86 years. Signal increase ratio time courses were decomposed into a fast Gaussian bulk-displacement and a slower Γ-variate perfusion-like component. Linear mixed-effects models were used to assess regional and age-related effects. Model fits were robust across all participants ( R 2 = 0.97). CSF transport metrics differed significantly across parasagittal dura subregions and the superior sagittal sinus. Age associations were heterogeneous: the perfusion-like component declined with age in upper parasagittal dura, increased in lower parasagittal regions, and remained relatively stable within the superior sagittal sinus. Additional timing and amplitude parameters exhibited region-specific age trajectories. These findings demonstrate regionally heterogeneous aging effects on meningeal CSF transport dynamics and suggest age-related redistribution rather than uniform decline, providing a noninvasive framework for assessing physiological remodeling of CSF transport with aging.
- Open Access
- 4 April 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Multiparametric CEST and Z-spectrum analysis proton (ZAP) as biomarkers of human brain aging
Chemical exchange saturation transfer (CEST) has been investigated to capture specific hydroxyl, amine, and amide protons. Z-spectrum analysis protons (ZAP) technique quantifies relaxation times of relatively free- ( $$\:{T}_{\:\:2,f}^{ex}$$ ) and restricted exchange proton ( $$\:{T}_{\:\:2,r}^{ex}$$ ) pools, and their fractions (F f and F r ) from a wider frequency range. Aging is related to brain neurodegeneration. However, the relationship between brain aging and macromolecular exchange protons remains unclear. Here we investigated brain aging by combining CEST and ZAP for comprehensive assessment of the macromolecules as potential biomarkers. Forty-three healthy adults (65.6 ± 16.0 years; 24 females) underwent 3-T experiments. Gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) were automatically segmented, and regions of interest were drawn in hippocampus, substantia nigra, globus pallidus, putamen, caudate, and thalamus. Spearman’s rank correlation coefficient analysis revealed significant age-related increases in F f across WM, CSF, hippocampus, substantia nigra, globus pallidus, and putamen (all P < 0.05), along with elevated $$\:{T}_{\:\:2,f}^{ex}$$ in the cortical GM, WM, and thalamus (all P < 0.05). Amine signal in CSF decreased with age ( P = 0.049). These results suggest age-related macromolecular alterations, highlighting CEST-ZAP metrics as promising biomarkers for brain aging and neurodegeneration.- 4 April 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessMultiparametric CEST and Z-spectrum analysis proton (ZAP) as biomarkers of human brain aging
Chemical exchange saturation transfer (CEST) has been investigated to capture specific hydroxyl, amine, and amide protons. Z-spectrum analysis protons (ZAP) technique quantifies relaxation times of relatively free- ( $$\:{T}_{\:\:2,f}^{ex}$$ ) and restricted exchange proton ( $$\:{T}_{\:\:2,r}^{ex}$$ ) pools, and their fractions (F f and F r ) from a wider frequency range. Aging is related to brain neurodegeneration. However, the relationship between brain aging and macromolecular exchange protons remains unclear. Here we investigated brain aging by combining CEST and ZAP for comprehensive assessment of the macromolecules as potential biomarkers. Forty-three healthy adults (65.6 ± 16.0 years; 24 females) underwent 3-T experiments. Gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) were automatically segmented, and regions of interest were drawn in hippocampus, substantia nigra, globus pallidus, putamen, caudate, and thalamus. Spearman’s rank correlation coefficient analysis revealed significant age-related increases in F f across WM, CSF, hippocampus, substantia nigra, globus pallidus, and putamen (all P < 0.05), along with elevated $$\:{T}_{\:\:2,f}^{ex}$$ in the cortical GM, WM, and thalamus (all P < 0.05). Amine signal in CSF decreased with age ( P = 0.049). These results suggest age-related macromolecular alterations, highlighting CEST-ZAP metrics as promising biomarkers for brain aging and neurodegeneration. - Open Access
- 12 March 2026
- Published by Springer Nature in Fluids and Barriers of the CNS
- Vol. 23 (1)
Bi-component modeling of cerebrospinal fluid outflow using Time-SLIP MRI
Background: Understanding egress outflow of cerebrospinal fluid (CSF) is essential for exploring its role in brain health and its relationship to neurodegenerative diseases. Existing models often fail to capture the complex flow dynamics, particularly distinguishing rapid bulk flow from slower, perfusion-like components. This study aims to develop and validate a bi-component model that characterizes these distinct signal patterns using Time-Spatial Labeling Inversion Pulse (Time-SLIP) MRI data. Methods: A bi-component model is proposed by combining a Gaussian function (to represent fast bulk outflow) with a Г-variate function (representing slower, perfusion-like flow). Validation phantom studies were conducted using a sealed water phantom with computer-controlled bulk flow. In-vivo meninges images in eight healthy subjects were acquired on a clinical 3T MRI using Time-SLIP with 3D single-shot FSE. Signal Increase Ratio (SIR) from these experiments were fitted using the proposed bi-component model with fitting accuracy assessed using coefficient of determination (R 2 ), Sum of Squared estimate of Errors (SSE), and Root Mean Square Error (RMSE). Results: Phantom studies showed superior fitting of bulk fluid dynamics by the Gaussian component, confirmed by lower SSE, RMSE and higher R 2 . The in-vivo results demonstrated that the bi-component model provided a superior fit, capturing two distinct components of CSF outflow, which are hypothesized to correspond to fast bulk flow and a slower, perfusion-like component, which could be a mixture of CSF and interstitial fluid. Conclusion: The bi-component model enhances characterization of CSF egress outflow from intrinsic labeling by Time-SLIP, providing potential quantitative biomarkers for the assessment of neurodegenerative diseases.
- 12 March 2026
- Published by Springer Nature in Fluids and Barriers of the CNS
- Vol. 23 (1)
Open AccessBi-component modeling of cerebrospinal fluid outflow using Time-SLIP MRI
Background: Understanding egress outflow of cerebrospinal fluid (CSF) is essential for exploring its role in brain health and its relationship to neurodegenerative diseases. Existing models often fail to capture the complex flow dynamics, particularly distinguishing rapid bulk flow from slower, perfusion-like components. This study aims to develop and validate a bi-component model that characterizes these distinct signal patterns using Time-Spatial Labeling Inversion Pulse (Time-SLIP) MRI data. Methods: A bi-component model is proposed by combining a Gaussian function (to represent fast bulk outflow) with a Г-variate function (representing slower, perfusion-like flow). Validation phantom studies were conducted using a sealed water phantom with computer-controlled bulk flow. In-vivo meninges images in eight healthy subjects were acquired on a clinical 3T MRI using Time-SLIP with 3D single-shot FSE. Signal Increase Ratio (SIR) from these experiments were fitted using the proposed bi-component model with fitting accuracy assessed using coefficient of determination (R 2 ), Sum of Squared estimate of Errors (SSE), and Root Mean Square Error (RMSE). Results: Phantom studies showed superior fitting of bulk fluid dynamics by the Gaussian component, confirmed by lower SSE, RMSE and higher R 2 . The in-vivo results demonstrated that the bi-component model provided a superior fit, capturing two distinct components of CSF outflow, which are hypothesized to correspond to fast bulk flow and a slower, perfusion-like component, which could be a mixture of CSF and interstitial fluid. Conclusion: The bi-component model enhances characterization of CSF egress outflow from intrinsic labeling by Time-SLIP, providing potential quantitative biomarkers for the assessment of neurodegenerative diseases.
- Open Access
- 1 January 2026
- Published by Japanese Society for Magnetic Resonance in Medicine in Magnetic Resonance in Medical Sciences
- Vol. 25 (1)
Perfusion Signal Analysis Using Multi-pulsed Arterial Spin Labeling (mPASL) with Multiple Post-labeling Delays: Phantom Validation and Application to the Human Foot
Purpose: This study aims to extend the general kinetic model (GKM) for perfusion signal analysis using multi-pulsed arterial spin labeling (mPASL) acquisitions with multiple post-labeling delays (mPLD). The approach aims to improve accuracy and gain potential for broader experimental and clinical applications.Methods: The magnetization vector evolution of the mPASL technique was analyzed using sequence diagrams and numerical simulation, supplemented by static phantom experiments. The GKM was adapted to support different configurations of mPASL tagging pulses in “dark” and “bright” methods. The proposed approach was validated on a constant-flow phantom and applied to in-vivo foot perfusion measurements in a cohort of 5 healthy subjects.Results: Simulations showed that the ratio between “dark” and “bright” mPASL methods is determined by fluid T1 relaxation time, the number of selective pulses, and labeling efficiency. Experiments with a constant-flow phantom demonstrated that GKM with mPASL enables semi-quantitative perfusion analysis, providing high-temporal-resolution perfusion curves. Estimated perfusion coefficients of constant flow phantom were consistent across acquisitions (5.1% variation), confirming the robustness of the GKM extension for mPASL with multiple post-labeling delays. However, in-vivo results deviated from simulation and constant flow experiments, highlighting potential physiological complexities, and model limitations.Conclusion: Extending the GKM to mPASL acquisitions demonstrates reliable performance under controlled constant flow conditions. Phantom experiments confirmed the accuracy of the approach, while in-vivo measurements in feet revealed deviations from simulation and constant flow results, suggesting the need to account for physiological factors and potential model extension due to pulsatile flow.
- 1 January 2026
- Published by Japanese Society for Magnetic Resonance in Medicine in Magnetic Resonance in Medical Sciences
- Vol. 25 (1)
Open AccessPerfusion Signal Analysis Using Multi-pulsed Arterial Spin Labeling (mPASL) with Multiple Post-labeling Delays: Phantom Validation and Application to the Human Foot
Purpose: This study aims to extend the general kinetic model (GKM) for perfusion signal analysis using multi-pulsed arterial spin labeling (mPASL) acquisitions with multiple post-labeling delays (mPLD). The approach aims to improve accuracy and gain potential for broader experimental and clinical applications.Methods: The magnetization vector evolution of the mPASL technique was analyzed using sequence diagrams and numerical simulation, supplemented by static phantom experiments. The GKM was adapted to support different configurations of mPASL tagging pulses in “dark” and “bright” methods. The proposed approach was validated on a constant-flow phantom and applied to in-vivo foot perfusion measurements in a cohort of 5 healthy subjects.Results: Simulations showed that the ratio between “dark” and “bright” mPASL methods is determined by fluid T1 relaxation time, the number of selective pulses, and labeling efficiency. Experiments with a constant-flow phantom demonstrated that GKM with mPASL enables semi-quantitative perfusion analysis, providing high-temporal-resolution perfusion curves. Estimated perfusion coefficients of constant flow phantom were consistent across acquisitions (5.1% variation), confirming the robustness of the GKM extension for mPASL with multiple post-labeling delays. However, in-vivo results deviated from simulation and constant flow experiments, highlighting potential physiological complexities, and model limitations.Conclusion: Extending the GKM to mPASL acquisitions demonstrates reliable performance under controlled constant flow conditions. Phantom experiments confirmed the accuracy of the approach, while in-vivo measurements in feet revealed deviations from simulation and constant flow results, suggesting the need to account for physiological factors and potential model extension due to pulsatile flow.
- Open Access
Three-Station Non-Contrast MR Angiography of the Lower Extremities Using Standard and Centric Fresh Blood Imaging
Background: Peripheral artery disease (PAD) is a manifestation of atherosclerosis that affects the extremities, leading to reduced perfusion and functional impairment. Non-contrast magnetic resonance angiography (NC-MRA) provides a safe and quantitative approach for early detection of PAD without the risks associated with contrast agents. The purpose of this study was to demonstrate the application of standard and centric ky-kz FBI techniques for rapid three-station NC-MRA of the entire lower extremity. Methods: This prospective cross-sectional study compared standard three-station fresh blood imaging (sFBI) with centric ky-kz ordered fresh blood imaging (cFBI) sequences in 10 healthy subjects and 3 patients with PAD (age range: 23–79 years; 7 females) using a 3-Tesla magnetic resonance imaging (MRI) system. Both sequences were acquired at the iliac, femoral, and tibial stations. Image quality (0–4 scale), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were evaluated. Statistical analysis was performed using repeated-measures analysis of variance (ANOVA) with significance set at α = 0.05. Results: Image quality did not differ significantly between sFBI and cFBI (p = 1.0). The iliac station exhibited lower image quality than the femoral station (p < 0.01). In a PAD patient with an iliac stent, cFBI preserved good image quality in the femoral and tibial stations, whereas sFBI was affected by N/2 aliasing artifacts. Both methods failed to visualize the stented iliac segment. Compared to sFBI, cFBI yielded significantly lower SNR (p < 0.01) and CNR (p < 0.001) but reduced total scan time by approximately 40% (468 s vs. 291 s). Conclusions: Three-station non-contrast FBI MRA of the peripheral arteries is feasible. The cFBI sequence substantially shortens scan time without compromising diagnostic image quality, offering practical advantages for clinical implementation, improved patient comfort, and reduced motion artifacts.
Open AccessThree-Station Non-Contrast MR Angiography of the Lower Extremities Using Standard and Centric Fresh Blood Imaging
Background: Peripheral artery disease (PAD) is a manifestation of atherosclerosis that affects the extremities, leading to reduced perfusion and functional impairment. Non-contrast magnetic resonance angiography (NC-MRA) provides a safe and quantitative approach for early detection of PAD without the risks associated with contrast agents. The purpose of this study was to demonstrate the application of standard and centric ky-kz FBI techniques for rapid three-station NC-MRA of the entire lower extremity. Methods: This prospective cross-sectional study compared standard three-station fresh blood imaging (sFBI) with centric ky-kz ordered fresh blood imaging (cFBI) sequences in 10 healthy subjects and 3 patients with PAD (age range: 23–79 years; 7 females) using a 3-Tesla magnetic resonance imaging (MRI) system. Both sequences were acquired at the iliac, femoral, and tibial stations. Image quality (0–4 scale), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were evaluated. Statistical analysis was performed using repeated-measures analysis of variance (ANOVA) with significance set at α = 0.05. Results: Image quality did not differ significantly between sFBI and cFBI (p = 1.0). The iliac station exhibited lower image quality than the femoral station (p < 0.01). In a PAD patient with an iliac stent, cFBI preserved good image quality in the femoral and tibial stations, whereas sFBI was affected by N/2 aliasing artifacts. Both methods failed to visualize the stented iliac segment. Compared to sFBI, cFBI yielded significantly lower SNR (p < 0.01) and CNR (p < 0.001) but reduced total scan time by approximately 40% (468 s vs. 291 s). Conclusions: Three-station non-contrast FBI MRA of the peripheral arteries is feasible. The cFBI sequence substantially shortens scan time without compromising diagnostic image quality, offering practical advantages for clinical implementation, improved patient comfort, and reduced motion artifacts.
- 10 September 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (1) , 220-221
Editorial for “Simultaneous Visualization of the Carotid and Subclavian Arteries Using Non‐Contrast–Enhanced MR Angiography With a 3D Fast Field Echo Sequence and Time‐Spatial Labeling Inversion Pulse: A Comparison With 3D Time‐of‐Flight MR Angiography”
- 10 September 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (1) , 220-221
Editorial for “Simultaneous Visualization of the Carotid and Subclavian Arteries Using Non‐Contrast–Enhanced MR Angiography With a 3D Fast Field Echo Sequence and Time‐Spatial Labeling Inversion Pulse: A Comparison With 3D Time‐of‐Flight MR Angiography”
- Open Access
- 1 January 2025
- Published by Japanese Society for Magnetic Resonance in Medicine in Magnetic Resonance in Medical Sciences
- Vol. 24 (4)
Fast Non-contrast MR Angiography Using a Zigzag Centric ky – kz k-space Trajectory and Exponential Refocusing Flip Angles with Restoration of Longitudinal Magnetization
Purpose: Fresh blood imaging (FBI) utilizes physiological blood signal differences between diastole and systole, causing a long acquisition time. The purpose of this study is to develop a fast FBI technique using a centric ky – kz k-space trajectory (cFBI) and an exponential refocusing flip angle (eFA) scheme with fast longitudinal restoration.Methods: This study was performed on 8 healthy subjects and 2 patients (peripheral artery disease and vascular disease) with informed consent, using a clinical 3-Tesla MRI scanner. A numeric simulation using extended phase graph (EPG) and phantom studies of eFA were carried out to investigate the restoration of longitudinal signal by lowering refocusing flip angles in later echoes. cFBI was then acquired on healthy subjects at the popliteal artery station to assess the effect of varying high/low flip ratios on the longitudinal restoration effects. In addition, trigger-delays of cFBI were optimized owing to the long acquisition window in zigzag centric ky – kz k-space trajectory. After optimizations, cFBI images were compared against standard FBI (sFBI) images in terms of scan time, motion artifacts, Nyquist N/2 artifacts, blurring, and overall image quality. We also performed two-way repeated measures analysis of variance.Results: cFBI with eFA achieved nearly a 50% scan time reduction compared to sFBI. The high/low flip angle of 180/2 degrees with lower refocusing pulses shows fast longitudinal restoration with the highest blood signals, yet also more sensitive to the background signals. Overall, 180/30 degrees images show reasonable blood signal recovery while minimizing the background signal artifacts. After the trigger delay optimization, maximum intensity projection image of cFBI after systole-diastole subtraction demonstrates less motion and N/2 artifacts than that of sFBI.Conclusion: Together with eFA for fast longitudinal signal restoration, the proposed cFBI technique achieved a 2-fold reduction in scan time and improved image quality without major artifacts.
- 1 January 2025
- Published by Japanese Society for Magnetic Resonance in Medicine in Magnetic Resonance in Medical Sciences
- Vol. 24 (4)
Open AccessFast Non-contrast MR Angiography Using a Zigzag Centric ky – kz k-space Trajectory and Exponential Refocusing Flip Angles with Restoration of Longitudinal Magnetization
Purpose: Fresh blood imaging (FBI) utilizes physiological blood signal differences between diastole and systole, causing a long acquisition time. The purpose of this study is to develop a fast FBI technique using a centric ky – kz k-space trajectory (cFBI) and an exponential refocusing flip angle (eFA) scheme with fast longitudinal restoration.Methods: This study was performed on 8 healthy subjects and 2 patients (peripheral artery disease and vascular disease) with informed consent, using a clinical 3-Tesla MRI scanner. A numeric simulation using extended phase graph (EPG) and phantom studies of eFA were carried out to investigate the restoration of longitudinal signal by lowering refocusing flip angles in later echoes. cFBI was then acquired on healthy subjects at the popliteal artery station to assess the effect of varying high/low flip ratios on the longitudinal restoration effects. In addition, trigger-delays of cFBI were optimized owing to the long acquisition window in zigzag centric ky – kz k-space trajectory. After optimizations, cFBI images were compared against standard FBI (sFBI) images in terms of scan time, motion artifacts, Nyquist N/2 artifacts, blurring, and overall image quality. We also performed two-way repeated measures analysis of variance.Results: cFBI with eFA achieved nearly a 50% scan time reduction compared to sFBI. The high/low flip angle of 180/2 degrees with lower refocusing pulses shows fast longitudinal restoration with the highest blood signals, yet also more sensitive to the background signals. Overall, 180/30 degrees images show reasonable blood signal recovery while minimizing the background signal artifacts. After the trigger delay optimization, maximum intensity projection image of cFBI after systole-diastole subtraction demonstrates less motion and N/2 artifacts than that of sFBI.Conclusion: Together with eFA for fast longitudinal signal restoration, the proposed cFBI technique achieved a 2-fold reduction in scan time and improved image quality without major artifacts.
- Open Access
- 9 September 2024
- Published by MDPI AG in Journal of Imaging
- Vol. 10 (9) , 223
Peripheral Non-Contrast MR Angiography Using FBI: Scan Time and T2 Blurring Reduction with 2D Parallel Imaging
Non-contrast magnetic resonance angiography (NC-MRA), including fresh blood imaging (FBI), is a suitable choice for evaluating patients with peripheral artery disease (PAD). We evaluated standard FBI (sFBI) and centric ky-kz FBI (cFBI) acquisitions, using 1D and 2D parallel imaging factors (PIFs) to assess the trade-off between scan time and image quality due to blurring. The bilateral legs of four volunteers (mean age 33 years, two females) were imaged in the coronal plane using a body array coil with a posterior spine coil. Two types of sFBI and cFBI sequences with 1D PIF factor 5 in the phase encode (PE) direction (in-plane) and 2D PIF 3 (PE) × 2 (slice encode (SE)) (in-plane, through-slice) were studied. Image quality was evaluated by a radiologist, the vessel’s signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured, and major vessel width was measured on the coronal maximum intensity projection (MIP) and 80-degree MIP. Results showed significant time reductions from 184 to 206 s on average when using sFBI down to 98 to 162 s when using cFBI (p = 0.003). Similar SNRs (averaging 200 to 370 across all sequences and PIF) and CNRs (averaging 190 to 360) for all techniques (p > 0.08) were found. There was no significant difference in the image quality (averaging 4.0 to 4.5; p > 0.2) or vessel width (averaging 4.1 to 4.9 mm; p > 0.1) on coronal MIP due to sequence or PIF. However, vessel width measured using 80-degree MIP demonstrated a significantly wider vessel in cFBI (5.6 to 6.8 mm) compared to sFBI (4.5 to 4.7 mm) (p = 0.022), and in 1D (4.7 to 6.8 mm) compared to 2D (4.5 to 5.6 mm) (p < 0.05) PIF. This demonstrated a trade-off in T2 blurring between 1D and 2D PIF: 1D using a PIF of 5 shortened the acquisition window, resulting in sharper arterial blood vessels in coronal images but significant blur in the 80-degree MIP. Two-dimensional PIF for cFBI provided a good balance between shorter scan time (relative to sFBI) and good sharpness in both in- and through-plane, while no benefit of 2D PIF was seen for sFBI. In conclusion, this study demonstrated the usefulness of FBI-based techniques for peripheral artery imaging and underscored the need to strike a balance between scan time and image quality in different planes through the use of 2D parallel imaging.
- 9 September 2024
- Published by MDPI AG in Journal of Imaging
- Vol. 10 (9) , 223
Open AccessPeripheral Non-Contrast MR Angiography Using FBI: Scan Time and T2 Blurring Reduction with 2D Parallel Imaging
Non-contrast magnetic resonance angiography (NC-MRA), including fresh blood imaging (FBI), is a suitable choice for evaluating patients with peripheral artery disease (PAD). We evaluated standard FBI (sFBI) and centric ky-kz FBI (cFBI) acquisitions, using 1D and 2D parallel imaging factors (PIFs) to assess the trade-off between scan time and image quality due to blurring. The bilateral legs of four volunteers (mean age 33 years, two females) were imaged in the coronal plane using a body array coil with a posterior spine coil. Two types of sFBI and cFBI sequences with 1D PIF factor 5 in the phase encode (PE) direction (in-plane) and 2D PIF 3 (PE) × 2 (slice encode (SE)) (in-plane, through-slice) were studied. Image quality was evaluated by a radiologist, the vessel’s signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured, and major vessel width was measured on the coronal maximum intensity projection (MIP) and 80-degree MIP. Results showed significant time reductions from 184 to 206 s on average when using sFBI down to 98 to 162 s when using cFBI (p = 0.003). Similar SNRs (averaging 200 to 370 across all sequences and PIF) and CNRs (averaging 190 to 360) for all techniques (p > 0.08) were found. There was no significant difference in the image quality (averaging 4.0 to 4.5; p > 0.2) or vessel width (averaging 4.1 to 4.9 mm; p > 0.1) on coronal MIP due to sequence or PIF. However, vessel width measured using 80-degree MIP demonstrated a significantly wider vessel in cFBI (5.6 to 6.8 mm) compared to sFBI (4.5 to 4.7 mm) (p = 0.022), and in 1D (4.7 to 6.8 mm) compared to 2D (4.5 to 5.6 mm) (p < 0.05) PIF. This demonstrated a trade-off in T2 blurring between 1D and 2D PIF: 1D using a PIF of 5 shortened the acquisition window, resulting in sharper arterial blood vessels in coronal images but significant blur in the 80-degree MIP. Two-dimensional PIF for cFBI provided a good balance between shorter scan time (relative to sFBI) and good sharpness in both in- and through-plane, while no benefit of 2D PIF was seen for sFBI. In conclusion, this study demonstrated the usefulness of FBI-based techniques for peripheral artery imaging and underscored the need to strike a balance between scan time and image quality in different planes through the use of 2D parallel imaging.
- Open Access
- 4 September 2024
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 37 (6) , 1119-1120
Correction to: Motion robust coronary MR angiography using zigzag centric ky–kz trajectory and high-resolution deep learning reconstruction
- 4 September 2024
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 37 (6) , 1119-1120
Open AccessCorrection to: Motion robust coronary MR angiography using zigzag centric ky–kz trajectory and high-resolution deep learning reconstruction