Effect of alkali metals on the accuracy of isotope ratio measurement of uranium by ICP-MS
- 6 August 2002
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 17 (9) , 1157-1160
Abstract
The effect of alkali metals on the accuracy of uranium isotope ratio measurements by inductively-coupled plasma sector field mass spectrometry (ICP-SFMS) was investigated. The isotope ratio measurements were performed on the isotopic reference materials, NBS SRM U-015 and U-350, in solutions containing various amounts of any one of Na, K and Rb. The mass bias of the instrument was corrected using an isotopic standard solution without alkali metals. The observed 235U/238U isotope ratios for SRM U-015 began to increase at around 1 μg g−1 for K and Rb, and at around 10 μg g−1 for Na. The deviations from the certified value at the concentration of 300 μg g−1 were evaluated to be 0.8%, 1.9% and 2.5% for Na, K and Rb, respectively. For SRM U-350, the 234U/238U, 235U/238U and 236U/238U isotope ratios were measured in various K concentrations. The deviation per unit mass at 300 μg g−1 K was evaluated as 0.56%.Keywords
This publication has 21 references indexed in Scilit:
- Determination of thorium and uranium isotope ratios in low-concentration geological materials using a fixed multi-collector-ICP-MSJournal of Analytical Atomic Spectrometry, 2001
- Improving isotope ratio precision in inductively coupled plasma quadrupole mass spectrometry by common analyte internal standardizationJournal of Analytical Atomic Spectrometry, 2001
- Plutonium isotope ratio analysis at femtogram to nanogram levels by multicollector ICP-MSJournal of Analytical Atomic Spectrometry, 2001
- Effect of concomitant elements on the distribution of ions in inductively coupled plasma-mass spectroscopy. Part 1. Elemental ionsSpectrochimica Acta Part B: Atomic Spectroscopy, 2000
- Concentrations of 239Pu and 240Pu and Their Isotopic Ratios Determined by ICP-MS in Soils Collected from the Chernobyl 30-km ZoneEnvironmental Science & Technology, 2000
- Lead isotopic and elemental analysis of copper alloy statuettes by double focusing sector field ICP mass spectrometryJournal of Analytical Atomic Spectrometry, 2000
- Lead isotope ratio analysis by inductively coupled plasma sector field mass spectrometry (ICP-SMS) in soil digests of a depth profileJournal of Analytical Atomic Spectrometry, 2000
- A calculation method based on isotope ratios for the determination of dead time and its uncertainty in ICP-MS and application of the method to investigating some features of a continuous dynode multiplierJournal of Analytical Atomic Spectrometry, 1999
- Non-spectral interferences caused by a saline water matrix in quadrupole and high resolution inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1998
- Validation of the analytical linearity and mass discrimination correction model exhibited by a multiple collector inductively coupled plasma mass spectrometer by means of a set of synthetic uranium isotope mixturesJournal of Analytical Atomic Spectrometry, 1995