Masaaki Magara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Masaaki Magara has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
F Esaka
1 shared publication- Fumitaka Esaka
Faculty of Science, Science University of Tokyo
1 shared publication H Nishimura
1 shared publicationK Watanabe
1 shared publicationK Yasuda
1 shared publication- Kazuo Watanabe
Department of Chemistry, Tokyo University of Science, 1-3 Kagurazaka, Shinjuku-ku, Tokyo 162-8601 Japan
1 shared publication
Latest Publications
- 6 August 2002
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 17 (9) , 1157-1160
Effect of alkali metals on the accuracy of isotope ratio measurement of uranium by ICP-MS
The effect of alkali metals on the accuracy of uranium isotope ratio measurements by inductively-coupled plasma sector field mass spectrometry (ICP-SFMS) was investigated. The isotope ratio measurements were performed on the isotopic reference materials, NBS SRM U-015 and U-350, in solutions containing various amounts of any one of Na, K and Rb. The mass bias of the instrument was corrected using an isotopic standard solution without alkali metals. The observed 235U/238U isotope ratios for SRM U-015 began to increase at around 1 μg g−1 for K and Rb, and at around 10 μg g−1 for Na. The deviations from the certified value at the concentration of 300 μg g−1 were evaluated to be 0.8%, 1.9% and 2.5% for Na, K and Rb, respectively. For SRM U-350, the 234U/238U, 235U/238U and 236U/238U isotope ratios were measured in various K concentrations. The deviation per unit mass at 300 μg g−1 K was evaluated as 0.56%.
- 6 August 2002
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 17 (9) , 1157-1160
Effect of alkali metals on the accuracy of isotope ratio measurement of uranium by ICP-MS
The effect of alkali metals on the accuracy of uranium isotope ratio measurements by inductively-coupled plasma sector field mass spectrometry (ICP-SFMS) was investigated. The isotope ratio measurements were performed on the isotopic reference materials, NBS SRM U-015 and U-350, in solutions containing various amounts of any one of Na, K and Rb. The mass bias of the instrument was corrected using an isotopic standard solution without alkali metals. The observed 235U/238U isotope ratios for SRM U-015 began to increase at around 1 μg g−1 for K and Rb, and at around 10 μg g−1 for Na. The deviations from the certified value at the concentration of 300 μg g−1 were evaluated to be 0.8%, 1.9% and 2.5% for Na, K and Rb, respectively. For SRM U-350, the 234U/238U, 235U/238U and 236U/238U isotope ratios were measured in various K concentrations. The deviation per unit mass at 300 μg g−1 K was evaluated as 0.56%.
- 1 July 2000
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 53 (1-2) , 87-90
Development of analytical techniques for ultra trace amounts of nuclear materials in environmental samples using ICP-MS for safeguards
- 1 July 2000
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 53 (1-2) , 87-90
Development of analytical techniques for ultra trace amounts of nuclear materials in environmental samples using ICP-MS for safeguards