A 3D global‐to‐local deformable mesh model based registration and anatomy‐constrained segmentation method for image guided prostate radiotherapy
- 25 February 2010
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 37 (3) , 1298-1308
Abstract
Purpose: In the external beam radiation treatment of prostate cancers, successful implementation of adaptive radiotherapy and conformal radiation dose delivery is highly dependent on precise and expeditious segmentation and registration of the prostate volume between the simulation and the treatment images. The purpose of this study is to develop a novel, fast, and accurate segmentation and registration method to increase the computational efficiency to meet the restricted clinical treatment time requirement in image guided radiotherapy.Methods: The method developed in this study used soft tissues to capture the transformation between the 3D planning CT (pCT) images and 3D cone‐beam CT (CBCT) treatment images. The method incorporated a global‐to‐local deformable mesh model based registration framework as well as an automatic anatomy‐constrained robust active shape model (ACRASM) based segmentation algorithm in the 3D CBCT images. The global registration was based on the mutual information method, and the local registration was to minimize the Euclidian distance of the corresponding nodal points from the global transformation of deformable mesh models, which implicitly used the information of the segmented target volume. The method was applied on six data sets of prostate cancer patients. Target volumes delineated by the same radiation oncologist on the pCT and CBCT were chosen as the benchmarks and were compared to the segmented and registered results. The distance‐based and the volume‐based estimators were used to quantitatively evaluate the results of segmentation and registration.Results: The ACRASM segmentation algorithm was compared to the original active shape model (ASM) algorithm by evaluating the values of the distance‐based estimators. With respect to the corresponding benchmarks, the mean distance ranged from −0.85 to 0.84 mm for ACRASM and from −1.44 to 1.17 mm for ASM. The mean absolute distance ranged from 1.77 to 3.07 mm for ACRASM and from 2.45 to 6.54 mm for ASM. The volume overlap ratio ranged from 79% to 91% for ACRASM and from 44% to 80% for ASM. These data demonstrated that the segmentation results of ACRASM were in better agreement with the corresponding benchmarks than those of ASM. The developed registration algorithm was quantitatively evaluated by comparing the registered target volumes from the pCT to the benchmarks on the CBCT. The mean distance and the root mean square error ranged from 0.38 to 2.2 mm and from 0.45 to 2.36 mm, respectively, between the CBCT images and the registered pCT. The mean overlap ratio of the prostate volumes ranged from 85.2% to 95% after registration. The average time of the ACRASM‐based segmentation was under 1 min. The average time of the global transformation was from 2 to 4 min on two 3D volumes and the average time of the local transformation was from 20 to 34 s on two deformable superquadrics mesh models.Conclusions: A novel and fast segmentation and deformable registration method was developed to capture the transformation between the planning and treatment images for external beam radiotherapy of prostate cancers. This method increases the computational efficiency and may provide foundation to achieve real time adaptive radiotherapy.Keywords
Funding Information
- Varian Medical Systems
This publication has 32 references indexed in Scilit:
- Automated registration of large deformations for adaptive radiation therapy of prostate cancerMedical Physics, 2009
- Cancer Statistics, 2008CA: A Cancer Journal for Clinicians, 2008
- A gradient feature weighted Minimax algorithm for registration of multiple portal images to 3DCT volumes in prostate radiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- A material sensitivity study on the accuracy of deformable organ registration using linear biomechanical modelsa)Medical Physics, 2006
- A feasibility study to investigate the use of thin-plate splines to account for prostate deformationPhysics in Medicine & Biology, 2005
- Entropy-based dual-portal-to-3-DCT registration incorporating pixel correlationIEEE Transactions on Medical Imaging, 2003
- A Minimax Entropy Registration Framework for Patient Setup Verification in RadiotherapyComputer Aided Surgery, 1999
- A minimax entropy registration framework for patient setup verification in radiotherapyComputer Aided Surgery, 1999
- Motion measurements in low-contrast X-ray imagery1998
- Active Shape Models-Their Training and ApplicationComputer Vision and Image Understanding, 1995