Ning J. Yue
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ning J. Yue has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Bruce G. Haffty
Department of Radiation Oncology, Cancer Institute of New Jersey, University of Medicine and Dentistry of New Jersey-Robert Wood Johnson Medical School, New Brunswick, New Jersey
5 shared publications- Sharad Goyal
Department of Radiation Oncology, School of Medicine and Health Sciences, George Washington University, Washington, DC 20052, USA
5 shared publications Sung Kim
Department of Radiation Oncology, Cancer Institute of New Jersey, University of Medicine and Dentistry of New Jersey-Robert Wood Johnson Medical School, New Brunswick, New Jersey
4 shared publicationsJinghao Zhou
Department of Radiation Oncology, The Cancer Institute of New Jersey, UMDNJ-Robert Wood Johnson Medical School, New Brunswick, New Jersey
3 shared publicationsSalma Jabbour
Department of Radiation Oncology, UMDNJ‐Robert Wood Johnson Medical School, The Cancer Institute of New Jersey, New Brunswick, New Jersey 08903
3 shared publications- Atif J. Khan
Memorial Sloan Kettering Cancer Center, New York, NY
2 shared publications
Latest Publications
- 1 January 2013
- Published by Springer Nature
- p. 57-63
Brachytherapy: Low Dose Rate (LDR) Temporary Implants
- 1 January 2013
- Published by Springer Nature
- p. 57-63
Brachytherapy: Low Dose Rate (LDR) Temporary Implants
- 1 April 2011
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 79 (5) , 1549-1556
Intrafractional Target Motions and Uncertainties of Treatment Setup Reference Systems in Accelerated Partial Breast Irradiation
- 1 April 2011
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 79 (5) , 1549-1556
Intrafractional Target Motions and Uncertainties of Treatment Setup Reference Systems in Accelerated Partial Breast Irradiation
- 25 February 2010
- Published by Wiley in Medical Physics
- Vol. 37 (3) , 1298-1308
A 3D global‐to‐local deformable mesh model based registration and anatomy‐constrained segmentation method for image guided prostate radiotherapy
Purpose: In the external beam radiation treatment of prostate cancers, successful implementation of adaptive radiotherapy and conformal radiation dose delivery is highly dependent on precise and expeditious segmentation and registration of the prostate volume between the simulation and the treatment images. The purpose of this study is to develop a novel, fast, and accurate segmentation and registration method to increase the computational efficiency to meet the restricted clinical treatment time requirement in image guided radiotherapy.Methods: The method developed in this study used soft tissues to capture the transformation between the 3D planning CT (pCT) images and 3D cone‐beam CT (CBCT) treatment images. The method incorporated a global‐to‐local deformable mesh model based registration framework as well as an automatic anatomy‐constrained robust active shape model (ACRASM) based segmentation algorithm in the 3D CBCT images. The global registration was based on the mutual information method, and the local registration was to minimize the Euclidian distance of the corresponding nodal points from the global transformation of deformable mesh models, which implicitly used the information of the segmented target volume. The method was applied on six data sets of prostate cancer patients. Target volumes delineated by the same radiation oncologist on the pCT and CBCT were chosen as the benchmarks and were compared to the segmented and registered results. The distance‐based and the volume‐based estimators were used to quantitatively evaluate the results of segmentation and registration.Results: The ACRASM segmentation algorithm was compared to the original active shape model (ASM) algorithm by evaluating the values of the distance‐based estimators. With respect to the corresponding benchmarks, the mean distance ranged from −0.85 to 0.84 mm for ACRASM and from −1.44 to 1.17 mm for ASM. The mean absolute distance ranged from 1.77 to 3.07 mm for ACRASM and from 2.45 to 6.54 mm for ASM. The volume overlap ratio ranged from 79% to 91% for ACRASM and from 44% to 80% for ASM. These data demonstrated that the segmentation results of ACRASM were in better agreement with the corresponding benchmarks than those of ASM. The developed registration algorithm was quantitatively evaluated by comparing the registered target volumes from the pCT to the benchmarks on the CBCT. The mean distance and the root mean square error ranged from 0.38 to 2.2 mm and from 0.45 to 2.36 mm, respectively, between the CBCT images and the registered pCT. The mean overlap ratio of the prostate volumes ranged from 85.2% to 95% after registration. The average time of the ACRASM‐based segmentation was under 1 min. The average time of the global transformation was from 2 to 4 min on two 3D volumes and the average time of the local transformation was from 20 to 34 s on two deformable superquadrics mesh models.Conclusions: A novel and fast segmentation and deformable registration method was developed to capture the transformation between the planning and treatment images for external beam radiotherapy of prostate cancers. This method increases the computational efficiency and may provide foundation to achieve real time adaptive radiotherapy.
- 25 February 2010
- Published by Wiley in Medical Physics
- Vol. 37 (3) , 1298-1308
A 3D global‐to‐local deformable mesh model based registration and anatomy‐constrained segmentation method for image guided prostate radiotherapy
Purpose: In the external beam radiation treatment of prostate cancers, successful implementation of adaptive radiotherapy and conformal radiation dose delivery is highly dependent on precise and expeditious segmentation and registration of the prostate volume between the simulation and the treatment images. The purpose of this study is to develop a novel, fast, and accurate segmentation and registration method to increase the computational efficiency to meet the restricted clinical treatment time requirement in image guided radiotherapy.Methods: The method developed in this study used soft tissues to capture the transformation between the 3D planning CT (pCT) images and 3D cone‐beam CT (CBCT) treatment images. The method incorporated a global‐to‐local deformable mesh model based registration framework as well as an automatic anatomy‐constrained robust active shape model (ACRASM) based segmentation algorithm in the 3D CBCT images. The global registration was based on the mutual information method, and the local registration was to minimize the Euclidian distance of the corresponding nodal points from the global transformation of deformable mesh models, which implicitly used the information of the segmented target volume. The method was applied on six data sets of prostate cancer patients. Target volumes delineated by the same radiation oncologist on the pCT and CBCT were chosen as the benchmarks and were compared to the segmented and registered results. The distance‐based and the volume‐based estimators were used to quantitatively evaluate the results of segmentation and registration.Results: The ACRASM segmentation algorithm was compared to the original active shape model (ASM) algorithm by evaluating the values of the distance‐based estimators. With respect to the corresponding benchmarks, the mean distance ranged from −0.85 to 0.84 mm for ACRASM and from −1.44 to 1.17 mm for ASM. The mean absolute distance ranged from 1.77 to 3.07 mm for ACRASM and from 2.45 to 6.54 mm for ASM. The volume overlap ratio ranged from 79% to 91% for ACRASM and from 44% to 80% for ASM. These data demonstrated that the segmentation results of ACRASM were in better agreement with the corresponding benchmarks than those of ASM. The developed registration algorithm was quantitatively evaluated by comparing the registered target volumes from the pCT to the benchmarks on the CBCT. The mean distance and the root mean square error ranged from 0.38 to 2.2 mm and from 0.45 to 2.36 mm, respectively, between the CBCT images and the registered pCT. The mean overlap ratio of the prostate volumes ranged from 85.2% to 95% after registration. The average time of the ACRASM‐based segmentation was under 1 min. The average time of the global transformation was from 2 to 4 min on two 3D volumes and the average time of the local transformation was from 20 to 34 s on two deformable superquadrics mesh models.Conclusions: A novel and fast segmentation and deformable registration method was developed to capture the transformation between the planning and treatment images for external beam radiotherapy of prostate cancers. This method increases the computational efficiency and may provide foundation to achieve real time adaptive radiotherapy.
- 8 December 2009
- Published by Wiley in Medical Physics
- Vol. 37 (1) , 197-210
Object-constrained meshless deformable algorithm for high speed 3D nonrigid registration between CT and CBCT
High-speed nonrigid registration between the planning CT and the treatment CBCT data is critical for real time image guided radiotherapy (IGRT) to improve the dose distribution and to reduce the toxicity to adjacent organs. The authors propose a new fully automatic 3D registration framework that integrates object-based global and seed constraints with the grayscale-based "demons" algorithm. Clinical objects were segmented on the planning CT images and were utilized as meshless deformable models during the nonrigid registration process. The meshless models reinforced a global constraint in addition to the grayscale difference between CT and CBCT in order to maintain the shape and the volume of geometrically complex 3D objects during the registration. To expedite the registration process, the framework was stratified into hierarchies, and the authors used a frequency domain formulation to diffuse the displacement between the reference and the target in each hierarchy. Also during the registration of pelvis images, they replaced the air region inside the rectum with estimated pixel values from the surrounding rectal wall and introduced an additional seed constraint to robustly track and match the seeds implanted into the prostate. The proposed registration framework and algorithm were evaluated on 15 real prostate cancer patients. For each patient, prostate gland, seminal vesicle, bladder, and rectum were first segmented by a radiation oncologist on planning CT images for radiotherapy planning purpose. The same radiation oncologist also manually delineated the tumor volumes and critical anatomical structures in the corresponding CBCT images acquired at treatment. These delineated structures on the CBCT were only used as the ground truth for the quantitative validation, while structures on the planning CT were used both as the input to the registration method and the ground truth in validation. By registering the planning CT to the CBCT, a displacement map was generated. Segmented volumes in the CT images deformed using the displacement field were compared against the manual segmentations in the CBCT images to quantitatively measure the convergence of the shape and the volume. Other image features were also used to evaluate the overall performance of the registration. The algorithm was able to complete the segmentation and registration process within 1 min, and the superimposed clinical objects achieved a volumetric similarity measure of over 90% between the reference and the registered data. Validation results also showed that the proposed registration could accurately trace the deformation inside the target volume with average errors of less than 1 mm. The method had a solid performance in registering the simulated images with up to 20 Hounsfield unit white noise added. Also, the side by side comparison with the original demons algorithm demonstrated its improved registration performance over the local pixel-based registration approaches. Given the strength and efficiency of the algorithm, the proposed method has significant clinical potential to accelerate and to improve the CBCT delineation and targets tracking in online IGRT applications.
- 8 December 2009
- Published by Wiley in Medical Physics
- Vol. 37 (1) , 197-210
Object-constrained meshless deformable algorithm for high speed 3D nonrigid registration between CT and CBCT
High-speed nonrigid registration between the planning CT and the treatment CBCT data is critical for real time image guided radiotherapy (IGRT) to improve the dose distribution and to reduce the toxicity to adjacent organs. The authors propose a new fully automatic 3D registration framework that integrates object-based global and seed constraints with the grayscale-based "demons" algorithm. Clinical objects were segmented on the planning CT images and were utilized as meshless deformable models during the nonrigid registration process. The meshless models reinforced a global constraint in addition to the grayscale difference between CT and CBCT in order to maintain the shape and the volume of geometrically complex 3D objects during the registration. To expedite the registration process, the framework was stratified into hierarchies, and the authors used a frequency domain formulation to diffuse the displacement between the reference and the target in each hierarchy. Also during the registration of pelvis images, they replaced the air region inside the rectum with estimated pixel values from the surrounding rectal wall and introduced an additional seed constraint to robustly track and match the seeds implanted into the prostate. The proposed registration framework and algorithm were evaluated on 15 real prostate cancer patients. For each patient, prostate gland, seminal vesicle, bladder, and rectum were first segmented by a radiation oncologist on planning CT images for radiotherapy planning purpose. The same radiation oncologist also manually delineated the tumor volumes and critical anatomical structures in the corresponding CBCT images acquired at treatment. These delineated structures on the CBCT were only used as the ground truth for the quantitative validation, while structures on the planning CT were used both as the input to the registration method and the ground truth in validation. By registering the planning CT to the CBCT, a displacement map was generated. Segmented volumes in the CT images deformed using the displacement field were compared against the manual segmentations in the CBCT images to quantitatively measure the convergence of the shape and the volume. Other image features were also used to evaluate the overall performance of the registration. The algorithm was able to complete the segmentation and registration process within 1 min, and the superimposed clinical objects achieved a volumetric similarity measure of over 90% between the reference and the registered data. Validation results also showed that the proposed registration could accurately trace the deformation inside the target volume with average errors of less than 1 mm. The method had a solid performance in registering the simulated images with up to 20 Hounsfield unit white noise added. Also, the side by side comparison with the original demons algorithm demonstrated its improved registration performance over the local pixel-based registration approaches. Given the strength and efficiency of the algorithm, the proposed method has significant clinical potential to accelerate and to improve the CBCT delineation and targets tracking in online IGRT applications.
- 10 September 2008
- Published by Wiley in Medical Physics
- Vol. 35 (10) , 4375-4385
Optimization of couch translational corrections to compensate for rotational and deformable target deviations in image guided radiotherapy
The utilization of image‐guided radiotherapy (IGRT) technologies helps correct temporal and spatial deviations of the target volume relative to planned radiation beams. With the aid of these IGRT technologies, it becomes possible to better identify the target volume before and even during radiation treatment. However, since components of the detected deviations may be translational, rotational, and deformable, the question remains whether simple treatment‐couch translational movement can be optimized to compensate for these complicated deviations. Deviation of the target volume and changes in patient body shape from that acquired for treatment planning may further add to the variations from planned dose distribution. In this study, an optimization strategy is developed to investigate these issues. The optimization process involved the use of the hill climbing algorithm, the detected target volume and patient body shape, and the dose distribution based on acquired images at treatment. During the process, the planned dose distribution was iteratively adjusted to reflect the changes of depth and distance as the translational treatment couch movement was being optimized. The optimal treatment couch movement was considered achieved when the highest fraction of the detected target volume was covered by prescription dose. This optimization strategy was evaluated on clinical prostate cancer cases. For each of the cases, cone beam computed tomography (CBCT) images were acquired right after fiducial marker‐based kilovolt orthogonal imaging verification and setup adjustment. Based on the CBCT images, the clinical target volume at the treatment was delineated and the translational treatment‐couch movements were optimized with the developed strategy. The resultant dose coverage was compared to that without the optimization. The results showed that with the present strategy, rotational and deformable target deviations can be further compensated with translational couch correction.
- 10 September 2008
- Published by Wiley in Medical Physics
- Vol. 35 (10) , 4375-4385
Optimization of couch translational corrections to compensate for rotational and deformable target deviations in image guided radiotherapy
The utilization of image‐guided radiotherapy (IGRT) technologies helps correct temporal and spatial deviations of the target volume relative to planned radiation beams. With the aid of these IGRT technologies, it becomes possible to better identify the target volume before and even during radiation treatment. However, since components of the detected deviations may be translational, rotational, and deformable, the question remains whether simple treatment‐couch translational movement can be optimized to compensate for these complicated deviations. Deviation of the target volume and changes in patient body shape from that acquired for treatment planning may further add to the variations from planned dose distribution. In this study, an optimization strategy is developed to investigate these issues. The optimization process involved the use of the hill climbing algorithm, the detected target volume and patient body shape, and the dose distribution based on acquired images at treatment. During the process, the planned dose distribution was iteratively adjusted to reflect the changes of depth and distance as the translational treatment couch movement was being optimized. The optimal treatment couch movement was considered achieved when the highest fraction of the detected target volume was covered by prescription dose. This optimization strategy was evaluated on clinical prostate cancer cases. For each of the cases, cone beam computed tomography (CBCT) images were acquired right after fiducial marker‐based kilovolt orthogonal imaging verification and setup adjustment. Based on the CBCT images, the clinical target volume at the treatment was delineated and the translational treatment‐couch movements were optimized with the developed strategy. The resultant dose coverage was compared to that without the optimization. The results showed that with the present strategy, rotational and deformable target deviations can be further compensated with translational couch correction.
- 13 May 2008
- Published by Wiley in Medical Physics
- Vol. 35 (6Part1) , 2286-2293
Energy spectrum based calculation of the half and the tenth value layers for brachytherapy sources using a semiempirical parametrized mass attenuation coefficient formulism
As different types of radionuclides (e.g., source) are introduced for clinical use in brachytherapy, the question is raised regarding whether a relatively simple method exists for the derivation of values of the half value layer (HVL) or the tenth value layer (TVL). For the radionuclide that has been clinically used for years, such as and , the sources have been manufactured and marketed by several vendors with different designs and structures. Because of the nature of emission of low energy photons for these radionuclides, energy spectra of the sources are very dependent on their individual designs. Though values of the HVL or the TVL in certain commonly used shielding materials are relatively small for these low energy photon emitting sources, the question remains how the variations in energy spectra affect the HVL (or TVL) values and whether these values can be calculated with a relatively simple method. A more fundamental question is whether a method can be established to derive the HVL (TVL) values for any brachytherapy sources and for different materials in a relatively straightforward fashion. This study was undertaken to answer these questions. Based on energy spectra, a well established semiempirical mass attenuation coefficient computing scheme was utilized to derive the HVL (TVL) values of different materials for different types of brachytherapy sources. The method presented in this study may be useful to estimate HVL (TVL) values of different materials for brachytherapy sources of different designs and containing different radionuclides.
- 13 May 2008
- Published by Wiley in Medical Physics
- Vol. 35 (6Part1) , 2286-2293
Energy spectrum based calculation of the half and the tenth value layers for brachytherapy sources using a semiempirical parametrized mass attenuation coefficient formulism
As different types of radionuclides (e.g., source) are introduced for clinical use in brachytherapy, the question is raised regarding whether a relatively simple method exists for the derivation of values of the half value layer (HVL) or the tenth value layer (TVL). For the radionuclide that has been clinically used for years, such as and , the sources have been manufactured and marketed by several vendors with different designs and structures. Because of the nature of emission of low energy photons for these radionuclides, energy spectra of the sources are very dependent on their individual designs. Though values of the HVL or the TVL in certain commonly used shielding materials are relatively small for these low energy photon emitting sources, the question remains how the variations in energy spectra affect the HVL (or TVL) values and whether these values can be calculated with a relatively simple method. A more fundamental question is whether a method can be established to derive the HVL (TVL) values for any brachytherapy sources and for different materials in a relatively straightforward fashion. This study was undertaken to answer these questions. Based on energy spectra, a well established semiempirical mass attenuation coefficient computing scheme was utilized to derive the HVL (TVL) values of different materials for different types of brachytherapy sources. The method presented in this study may be useful to estimate HVL (TVL) values of different materials for brachytherapy sources of different designs and containing different radionuclides.
- 10 August 2007
- Published by Wiley in Medical Physics
- Vol. 34 (9) , 3500-3509
The effect of respiratory cycle and radiation beam‐on timing on the dose distribution of free‐breathing breast treatment using dynamic IMRT
In breast cancer treatment, intensity‐modulated radiation therapy (IMRT) can be utilized to deliver more homogeneous dose to target tissues to minimize the cosmetic impact. We have investigated the effect of the respiratory cycle and radiation beam‐on timing on the dose distribution in free‐breathing dynamic breast IMRT treatment. Six patients with early stage cancer of the left breast were included in this study. A helical computed tomography (CT) scan was acquired for treatment planning. A four‐dimensional computed tomography (4D CT) scan was obtained right after the helical CT scan with little or no setup uncertainty to simulate patient respiratory motion. After optimizing based on the helical CT scan, the sliding‐window dynamic multileaf collimator (DMLC) leaf sequence was segmented into multiple sections that corresponded to various respiratory phases per respiratory cycle and radiation beam‐on timing. The segmented DMLC leaf sections were grouped according to respiratory phases and superimposed over the radiation fields of corresponding 4D CT image set. Dose calculation was then performed for each phase of the 4D CT scan. The total dose distribution was computed by accumulating the contribution of dose from each phase to every voxel in the region of interest. This was tracked by a deformable registration program throughout all of the respiratory phases of the 4D CT scan. A dose heterogeneity index, defined as the ratio between and the prescription dose, was introduced to numerically illustrate the impact of respiratory motion on the dose distribution of treatment volume. A respiratory cycle range of and randomly distributed beam‐on timing were assigned to simulate the patient respiratory motion during the free‐breathing treatment. The results showed that the respiratory cycle period and radiation beam‐on timing presented limited impact on the target dose coverage and slightly increased the target dose heterogeneity. This motion impact tended to increase the variation of target dose coverage and heterogeneity between treatment fractions with different radiation beam‐on timing. The target dose coverage and heterogeneity were more susceptible to the radiation beam‐on timing for patients with long respiratory cycle (longer than ) and large breast motion amplitudes (larger than ). The same results could be found for respiratory cycle up to and respiratory motion amplitude up to . The heart dose distribution did not change significantly regardless of respiratory cycle and radiation beam‐on timing.
- 10 August 2007
- Published by Wiley in Medical Physics
- Vol. 34 (9) , 3500-3509
The effect of respiratory cycle and radiation beam‐on timing on the dose distribution of free‐breathing breast treatment using dynamic IMRT
In breast cancer treatment, intensity‐modulated radiation therapy (IMRT) can be utilized to deliver more homogeneous dose to target tissues to minimize the cosmetic impact. We have investigated the effect of the respiratory cycle and radiation beam‐on timing on the dose distribution in free‐breathing dynamic breast IMRT treatment. Six patients with early stage cancer of the left breast were included in this study. A helical computed tomography (CT) scan was acquired for treatment planning. A four‐dimensional computed tomography (4D CT) scan was obtained right after the helical CT scan with little or no setup uncertainty to simulate patient respiratory motion. After optimizing based on the helical CT scan, the sliding‐window dynamic multileaf collimator (DMLC) leaf sequence was segmented into multiple sections that corresponded to various respiratory phases per respiratory cycle and radiation beam‐on timing. The segmented DMLC leaf sections were grouped according to respiratory phases and superimposed over the radiation fields of corresponding 4D CT image set. Dose calculation was then performed for each phase of the 4D CT scan. The total dose distribution was computed by accumulating the contribution of dose from each phase to every voxel in the region of interest. This was tracked by a deformable registration program throughout all of the respiratory phases of the 4D CT scan. A dose heterogeneity index, defined as the ratio between and the prescription dose, was introduced to numerically illustrate the impact of respiratory motion on the dose distribution of treatment volume. A respiratory cycle range of and randomly distributed beam‐on timing were assigned to simulate the patient respiratory motion during the free‐breathing treatment. The results showed that the respiratory cycle period and radiation beam‐on timing presented limited impact on the target dose coverage and slightly increased the target dose heterogeneity. This motion impact tended to increase the variation of target dose coverage and heterogeneity between treatment fractions with different radiation beam‐on timing. The target dose coverage and heterogeneity were more susceptible to the radiation beam‐on timing for patients with long respiratory cycle (longer than ) and large breast motion amplitudes (larger than ). The same results could be found for respiratory cycle up to and respiratory motion amplitude up to . The heart dose distribution did not change significantly regardless of respiratory cycle and radiation beam‐on timing.
- 10 May 2007
- Published by Wiley in Medical Physics
- Vol. 34 (6Part1) , 1975-1982
On the assay of brachytherapy sources
In many of brachytherapy procedures, a large amount of radioactive sources are used to deliver desired doses to the target volume. It is both the federal regulation recommendation (US Nuclear Regulatory Commission, 10 CFR 35.432) and recommendations of the American Association of Physicists in Medicine (AAPM) [Kutcher et al., Med. Phys. 21, 581–618 (1994); Nath et al., Med. Phys. 24, 1557–1598 (1997)] that users independently verify the sources’ strength. Though the reports of AAPM Task Group 40 [Kutcher et al., Med. Phys. 21, 581–618 (1994)] and 56 [Nath et al., Med. Phys. 24, 1557–1598 (1997)] have made specific recommendations on the assay of brachytherapy sources, the relevant statistical significance of the recommendations remain unanswered. In this study, statistical theories were used and a method was presented to quantify the assay process of brachytherapy sources and to evaluate the recommendations. The results showed that the quality of a source assay process was dependent on the measured source strength deviation and number of assayed sources. Its dependence on the total number of sources becomes statistically insignificant if the total number is large enough. It was concluded that the assay process can be determined by the obtained assay information, instead of a preset percentage of total sources. It was further found that the use of manufacturer's stated strength value may possibly lead to bigger uncertainty in source strength accuracy, unless the manufacturer's stated strength is the measured mean value of all the ordered sources.
- 10 May 2007
- Published by Wiley in Medical Physics
- Vol. 34 (6Part1) , 1975-1982
On the assay of brachytherapy sources
In many of brachytherapy procedures, a large amount of radioactive sources are used to deliver desired doses to the target volume. It is both the federal regulation recommendation (US Nuclear Regulatory Commission, 10 CFR 35.432) and recommendations of the American Association of Physicists in Medicine (AAPM) [Kutcher et al., Med. Phys. 21, 581–618 (1994); Nath et al., Med. Phys. 24, 1557–1598 (1997)] that users independently verify the sources’ strength. Though the reports of AAPM Task Group 40 [Kutcher et al., Med. Phys. 21, 581–618 (1994)] and 56 [Nath et al., Med. Phys. 24, 1557–1598 (1997)] have made specific recommendations on the assay of brachytherapy sources, the relevant statistical significance of the recommendations remain unanswered. In this study, statistical theories were used and a method was presented to quantify the assay process of brachytherapy sources and to evaluate the recommendations. The results showed that the quality of a source assay process was dependent on the measured source strength deviation and number of assayed sources. Its dependence on the total number of sources becomes statistically insignificant if the total number is large enough. It was concluded that the assay process can be determined by the obtained assay information, instead of a preset percentage of total sources. It was further found that the use of manufacturer's stated strength value may possibly lead to bigger uncertainty in source strength accuracy, unless the manufacturer's stated strength is the measured mean value of all the ordered sources.