Comparison of Dosimetry Protocols for Electron Beam Radiotherapy Calibrations and Measurement Uncertainties
Open Access
Abstract
This paper presents guidelines for the calibration of radiation beams that were issued by the International Atomic Energy Agency (IAEA TRS 398), the American Association of Physicists in Medicine (AAPM TG 51) and the German task group (DIN 6800-2). These protocols are based on the use of an ionization chamber calibrated in terms of absorbed dose to water in a standard laboratory’s reference quality beam, where the previous protocols were based on air kerma standards. This study aims to determine uncertainties in dosimetry for electron beam radiotherapy using internationally established high-energy radiotherapy beam calibration standards. Methods: Dw was determined in 6-, 12- and 18 MeV electron energies under reference conditions using three cylindrical and two plane-parallel ion chambers in concert with the IAEA TRS 398, AAPM TG 51 and DIN 6800-2 absorbed dose protocols. From mean measured Dw values, the ratio TRS 398/TG 51 was found to vary between 0.988 and 1.004, while for the counterpart TRS 398/DIN 6800-2 and TG 51/DIN 6800-2, the variation ranges were 0.991–1.003 and 0.997–1.005, respectively. For the cylindrical chambers, the relative combined uncertainty (k = 1) in absorbed dose measurements was 1.44%, while for the plane-parallel chambers, it ranged from 1.53 to 1.88%. Conclusions: A high degree of consistency was demonstrated among the three protocols. It is suggested that in the use of the presently determined dose conversion factors across the three protocols, dose intercomparisons can be facilitated between radiotherapy centres.Keywords
Funding Information
- Imam Mohammad Ibn Saud Islamic University (RG-21-09-45.)
This publication has 10 references indexed in Scilit:
- Direct measurement of ionization chamber absorbed dose k factors in clinical electron beamsRadiation Measurements, 2020
- An on-site dosimetry audit for high-energy electron beamsPhysics and Imaging in Radiation Oncology, 2018
- A comparison of protocols for external beam radiotherapy beam calibrationsApplied Radiation and Isotopes, 2012
- Beam quality corrections for parallel-plate ion chambers in electron reference dosimetryPhysics in Medicine & Biology, 2012
- Reference Dosimetry according to the New German Protocol DIN 6800-2 and Comparison with IAEA TRS 398 and AAPM TG 51*Biomedical Imaging and Intervention Journal, 2011
- Study of the uncertainty in the determination of the absorbed dose to water during external beam radiotherapy calibrationJournal of Applied Clinical Medical Physics, 2008
- Absolute dose determination in high-energy electron beams: Comparison of IAEA dosimetry protocolsJournal of Medical Physics, 2008
- Bestimmung der Energiedosis in Wasser für hochenergetische Photonen- und Elektronenstrahlung – Vergleich verschiedener Dosimetrieprotokolle1,2Zeitschrift für Medizinische Physik, 2003
- AAPM's TG‐51 protocol for clinical reference dosimetry of high‐energy photon and electron beamsMedical Physics, 1999
- Code of Practice for high-energy photon therapy dosimetry based on the NPL absorbed dose calibration servicePhysics in Medicine & Biology, 1990