Sitah Alanazi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sitah Alanazi has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Karem. A. Mahmoud
Ural Federal University
3 shared publications - Mansour Almurayshid
King Abdulaziz City for Science and Technology (KACST), P.O. Box 6086, Riyadh 11442, Saudi Arabia
3 shared publications - Mohammad Wasef Marashdeh
Department of Physics, College of Sciences, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh, Saudi Arabia
3 shared publications - Mohammed Alsuhybani
King Abdulaziz City for Science and Technology (KACST), P.O. Box 6086, Riyadh 11442, Saudi Arabia
2 shared publications Mohannad Al-Hmoud
2 shared publications- Nawal Madkhali
Department of Physics, College of Science, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 11623, Saudi Arabia
2 shared publications
Latest Publications
- Open Access
Mechanical, Thermal and X-Ray Shielding Properties of Lead-Free Composites of HDPE Filled with Metal-Based Powders
The increasing utilization of radiation in medicine, industry, and water purification highlights the need for efficient radiation-protection materials. This study investigates lead-free polymer composites based on high-density polyethylene (HDPE) filled with four metallic fillers: tungsten carbide (WC), molybdenum carbide (MoC), tungsten (W), and molybdenum (Mo) at 15 wt%. The objective is to evaluate their potential as alternatives to lead for shielding ionizing radiation. Mechanical performance was examined through tensile testing, while thermal stability was assessed based on the residual mass. Radiation-attenuation behavior was analyzed through linear and mass attenuation coefficients (µ and µₘ), radiation protection efficiency (RPE), half-value layer (HVL), mean free path (MFP), buildup factors (B), and effective atomic number (Zeff) within the 47.9–248 keV energy range. The HDPE/W composite exhibited the greatest enhancement, with a mass attenuation coefficient (µₘ) 82.5% higher than that of pure HDPE, along with the highest linear attenuation coefficient (µ). Furthermore, tungsten-loaded samples achieved an RPE of 98.05% at 47.9 keV. The increased density, low B, and high Zeff values collectively contribute to superior shielding performance. These findings indicate that HDPE filled with WC, MoC, W, and Mo are promising lead-free candidates for low-energy X-ray shielding applications.
Open AccessMechanical, Thermal and X-Ray Shielding Properties of Lead-Free Composites of HDPE Filled with Metal-Based Powders
The increasing utilization of radiation in medicine, industry, and water purification highlights the need for efficient radiation-protection materials. This study investigates lead-free polymer composites based on high-density polyethylene (HDPE) filled with four metallic fillers: tungsten carbide (WC), molybdenum carbide (MoC), tungsten (W), and molybdenum (Mo) at 15 wt%. The objective is to evaluate their potential as alternatives to lead for shielding ionizing radiation. Mechanical performance was examined through tensile testing, while thermal stability was assessed based on the residual mass. Radiation-attenuation behavior was analyzed through linear and mass attenuation coefficients (µ and µₘ), radiation protection efficiency (RPE), half-value layer (HVL), mean free path (MFP), buildup factors (B), and effective atomic number (Zeff) within the 47.9–248 keV energy range. The HDPE/W composite exhibited the greatest enhancement, with a mass attenuation coefficient (µₘ) 82.5% higher than that of pure HDPE, along with the highest linear attenuation coefficient (µ). Furthermore, tungsten-loaded samples achieved an RPE of 98.05% at 47.9 keV. The increased density, low B, and high Zeff values collectively contribute to superior shielding performance. These findings indicate that HDPE filled with WC, MoC, W, and Mo are promising lead-free candidates for low-energy X-ray shielding applications.
- 16 December 2025
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics B
- Vol. 40 (03)
Modeling the electronic, optical, mechanical, and thermoelectric performance in TM-based ternary tellurides: First-principles investigation
Using density functional theory and Boltzmann transport calculations, this work presents an extensive first-principles study of the structural, electronic, optical, mechanical and thermoelectric properties of MgCdTe 2 and ZnCdTe 2 ternary tellurides. ZnCdTe 2 shows stronger interatomic bonding than MgCdTe 2 , demonstrated by its larger cohesive energy of [ ] [ ]eV/atom and formation energy of [ ] [ ]eV/atom. The TB-mBJ calculation gives a direct band gap of 2.47[ ]eV for MgCdTe 2 and 2.00[ ]eV for ZnCdTe 2 . Mechanically, the ZnCdTe 2 shows a stronger ductility with a greater Pugh ratio and the Poisson’s ratio, while the MgCdTe 2 shows greater Young’s modulus and the shear modulus, suggesting better stiffness and resistance to the deformation. The materials are observed as direct band gap materials, as noticed by their electronic structure calculations with the TB-mBJ. These materials also optically display considerable UV absorption. ZnCdTe 2 shows more noticeable energy loss features and greater absorption coefficients, validating their applications in the photovoltaics and the photodetectors. A ZT value of 0.10 at around 800[ ]K for ZnCdTe 2 works better compared with the MgCdTe 2 , with a greater Seebeck coefficient of [ ] [ ]V/K and greater electrical conductivity. Because of the excellent stability, optical performance and the thermoelectric effectiveness, ZnCdTe 2 precisely stands out as a more active multifunctional material.
- 16 December 2025
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics B
- Vol. 40 (03)
Modeling the electronic, optical, mechanical, and thermoelectric performance in TM-based ternary tellurides: First-principles investigation
Using density functional theory and Boltzmann transport calculations, this work presents an extensive first-principles study of the structural, electronic, optical, mechanical and thermoelectric properties of MgCdTe 2 and ZnCdTe 2 ternary tellurides. ZnCdTe 2 shows stronger interatomic bonding than MgCdTe 2 , demonstrated by its larger cohesive energy of [ ] [ ]eV/atom and formation energy of [ ] [ ]eV/atom. The TB-mBJ calculation gives a direct band gap of 2.47[ ]eV for MgCdTe 2 and 2.00[ ]eV for ZnCdTe 2 . Mechanically, the ZnCdTe 2 shows a stronger ductility with a greater Pugh ratio and the Poisson’s ratio, while the MgCdTe 2 shows greater Young’s modulus and the shear modulus, suggesting better stiffness and resistance to the deformation. The materials are observed as direct band gap materials, as noticed by their electronic structure calculations with the TB-mBJ. These materials also optically display considerable UV absorption. ZnCdTe 2 shows more noticeable energy loss features and greater absorption coefficients, validating their applications in the photovoltaics and the photodetectors. A ZT value of 0.10 at around 800[ ]K for ZnCdTe 2 works better compared with the MgCdTe 2 , with a greater Seebeck coefficient of [ ] [ ]V/K and greater electrical conductivity. Because of the excellent stability, optical performance and the thermoelectric effectiveness, ZnCdTe 2 precisely stands out as a more active multifunctional material.
- 5 November 2024
- Published by IOP Publishing in Physica Scripta
- Vol. 99 (12) , 125011
Preparation of bimetallic calcium chromatite nanocomposite using Stevia rebaudiana leaf extract for inducing apoptosis in human cancer cell lines
Despite the widespread industrial use of chromium-based compounds, there are concerns regarding their toxicity in biomedical applications. Herein, bimetallic calcium chromatite nanocomposite (CC) was prepared through green synthesis using Stevia rebaudiana leaf extract. A porous nanorod of CC was obtained through calcinations at 800 °C. The formation of CC was confirmed by SEM (scanning electron microscopy), EDAX (Energy-dispersive x-ray spectroscopy), HRTEM (High-resolution transmission electron microscopy), TGA (Thermal gravimetric analysis), and BET (Brunauer–Emmett–Teller). The cytotoxicity of the CC was evaluated by the MTT method against cancer lines (HeLa, U87, A549) and primary cell line (HUVEC). The IC50 value of CC against cancer cell lines was lower than the primary cell lines. The calculated specificity index was greater than one, indicating that this CC might target cancer cells without the use of a targeting moiety. Gene expression studies revealed that CC upregulated the proapoptotic gene, BAX and downregulated the anti-apoptotic gene, Bcl-2, to induce apoptosis. The KDR and VEGF genes responsible for angiogenesis were down-regulated, indicating that CC decreases angiogenesis to promote apoptosis. The findings suggest CC prepared using phytoextract could be considered an adjuvant cancer therapy treatment.
- 5 November 2024
- Published by IOP Publishing in Physica Scripta
- Vol. 99 (12) , 125011
Preparation of bimetallic calcium chromatite nanocomposite using Stevia rebaudiana leaf extract for inducing apoptosis in human cancer cell lines
Despite the widespread industrial use of chromium-based compounds, there are concerns regarding their toxicity in biomedical applications. Herein, bimetallic calcium chromatite nanocomposite (CC) was prepared through green synthesis using Stevia rebaudiana leaf extract. A porous nanorod of CC was obtained through calcinations at 800 °C. The formation of CC was confirmed by SEM (scanning electron microscopy), EDAX (Energy-dispersive x-ray spectroscopy), HRTEM (High-resolution transmission electron microscopy), TGA (Thermal gravimetric analysis), and BET (Brunauer–Emmett–Teller). The cytotoxicity of the CC was evaluated by the MTT method against cancer lines (HeLa, U87, A549) and primary cell line (HUVEC). The IC50 value of CC against cancer cell lines was lower than the primary cell lines. The calculated specificity index was greater than one, indicating that this CC might target cancer cells without the use of a targeting moiety. Gene expression studies revealed that CC upregulated the proapoptotic gene, BAX and downregulated the anti-apoptotic gene, Bcl-2, to induce apoptosis. The KDR and VEGF genes responsible for angiogenesis were down-regulated, indicating that CC decreases angiogenesis to promote apoptosis. The findings suggest CC prepared using phytoextract could be considered an adjuvant cancer therapy treatment.
- Open Access
Evaluating the Effects of Metallic Waste on the Structural and Gamma-Ray Shielding Properties of Epoxy Composites
The objective of the research is to develop novel materials that are both inexpensive and have a low density, while also being able to endure the transportation of γ-photons with low-to-medium energy levels. The outcome consisted of four epoxy resins that were strengthened with different quantities of heavy metallic waste. The density of the formed composites improved from 1.134 ± 0.022 g/cm3 to 1.560 ± 0.0312 g/cm3 when the waste content was raised from 0 to 40 weight percent. The theoretical investigation was determined using Monte Carlo (MCNP) simulation software, and the results of linear attenuation coefficient were justified experimentally in a low and medium energy range of 15–662 keV. The mass attenuation coefficient results in a low gamma energy range (15–122 keV) varied in between 3.175 and 0.159 cm2/g (for E-MW0 composite) and in between 8.212 and 0.164 cm2/g (for E-MW40 composite). The decrease in mass attenuation coefficient was detected in a medium gamma photon energy range (122–662 keV) with 0.123–0.082 cm2/g (for E-MW0 composite) and 0.121–0.080 cm2/g (for E-MW40 composite). The density of the enhanced composites influenced these parameters. As the metallic waste composition increased, the fabricated composites’ half-value thickness decreased. At 15 keV, the half-value thickness decreased from 0.19 to 0.05 cm. At 59 keV, it fell from 2.70 to 1.41 cm. At 122 keV, it fell from 3.90 to 2.72 cm. At 662 keV, it fell from 7.45 to 5.56 cm. This decrease occurred as the heavy metal waste concentration increased from 0 to 40 wt.%. The study indicates that as metallic waste concentrations rise, there is a rise in the effective atomic number and a decline in the buildup factors.
Open AccessEvaluating the Effects of Metallic Waste on the Structural and Gamma-Ray Shielding Properties of Epoxy Composites
The objective of the research is to develop novel materials that are both inexpensive and have a low density, while also being able to endure the transportation of γ-photons with low-to-medium energy levels. The outcome consisted of four epoxy resins that were strengthened with different quantities of heavy metallic waste. The density of the formed composites improved from 1.134 ± 0.022 g/cm3 to 1.560 ± 0.0312 g/cm3 when the waste content was raised from 0 to 40 weight percent. The theoretical investigation was determined using Monte Carlo (MCNP) simulation software, and the results of linear attenuation coefficient were justified experimentally in a low and medium energy range of 15–662 keV. The mass attenuation coefficient results in a low gamma energy range (15–122 keV) varied in between 3.175 and 0.159 cm2/g (for E-MW0 composite) and in between 8.212 and 0.164 cm2/g (for E-MW40 composite). The decrease in mass attenuation coefficient was detected in a medium gamma photon energy range (122–662 keV) with 0.123–0.082 cm2/g (for E-MW0 composite) and 0.121–0.080 cm2/g (for E-MW40 composite). The density of the enhanced composites influenced these parameters. As the metallic waste composition increased, the fabricated composites’ half-value thickness decreased. At 15 keV, the half-value thickness decreased from 0.19 to 0.05 cm. At 59 keV, it fell from 2.70 to 1.41 cm. At 122 keV, it fell from 3.90 to 2.72 cm. At 662 keV, it fell from 7.45 to 5.56 cm. This decrease occurred as the heavy metal waste concentration increased from 0 to 40 wt.%. The study indicates that as metallic waste concentrations rise, there is a rise in the effective atomic number and a decline in the buildup factors.
- Open Access
Fabrication, Structural Characterization, and Photon Attenuation Efficiency Investigation of Polymer-Based Composites
Experiments have assessed various polymer composites for radiation shielding in diverse applications. These composites are lighter and non-toxic when compared to lead (Pb), making them particularly effective in diagnostic imaging for shielding against low-energy photons. This study demonstrates the fabrication of four composites by combining a base material, specifically a high-density polyethylene (HDPE) polymer, with 10% and 20% silicon (Si) and silicon carbide (SiC), respectively. Additionally, 5% molybdenum (Mo) was incorporated into the composites as a heavy metal element. The composites obtained were fabricated into 20 disks with a uniform thickness of 2 mm each. Discs were exposed to radiation from a low-energy X-ray source (32.5–64.5 keV). The chemical and physical properties of composites were assessed. The shielding ability of samples was evaluated by determining the linear and mass attenuation coefficients (μ and μm), radiation protection efficiency (RPE), half-value layer (HVL), and mean free path (MFP). According to our findings, supplementing HDPE with additives improved the attenuation of beams. The μm values showed that composite X-ray shielding characteristics were enhanced with filler concentration for both Si and SiC. Polymer composites with micro-molecule fillers shelter X-rays better than polymers, especially at low energy. The HVL and MFB values of the filler are lower than those of the pure HDPE sample, indicating that less thickness is needed to shield at the appropriate energy. HC-20 blocked 92% of the incident beam at 32.5 keV. This study found that increasing the composite sample thickness or polymer filler percentage could shield against low-energy radiation.
Open AccessFabrication, Structural Characterization, and Photon Attenuation Efficiency Investigation of Polymer-Based Composites
Experiments have assessed various polymer composites for radiation shielding in diverse applications. These composites are lighter and non-toxic when compared to lead (Pb), making them particularly effective in diagnostic imaging for shielding against low-energy photons. This study demonstrates the fabrication of four composites by combining a base material, specifically a high-density polyethylene (HDPE) polymer, with 10% and 20% silicon (Si) and silicon carbide (SiC), respectively. Additionally, 5% molybdenum (Mo) was incorporated into the composites as a heavy metal element. The composites obtained were fabricated into 20 disks with a uniform thickness of 2 mm each. Discs were exposed to radiation from a low-energy X-ray source (32.5–64.5 keV). The chemical and physical properties of composites were assessed. The shielding ability of samples was evaluated by determining the linear and mass attenuation coefficients (μ and μm), radiation protection efficiency (RPE), half-value layer (HVL), and mean free path (MFP). According to our findings, supplementing HDPE with additives improved the attenuation of beams. The μm values showed that composite X-ray shielding characteristics were enhanced with filler concentration for both Si and SiC. Polymer composites with micro-molecule fillers shelter X-rays better than polymers, especially at low energy. The HVL and MFB values of the filler are lower than those of the pure HDPE sample, indicating that less thickness is needed to shield at the appropriate energy. HC-20 blocked 92% of the incident beam at 32.5 keV. This study found that increasing the composite sample thickness or polymer filler percentage could shield against low-energy radiation.
- Open Access
- 19 February 2024
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (7) , 2740-2747
The influence of Ni ion addition on the microstructure and gamma ray shielding ability of ferromagnetic CuFe2O4 ceramic material
- 19 February 2024
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (7) , 2740-2747
Open AccessThe influence of Ni ion addition on the microstructure and gamma ray shielding ability of ferromagnetic CuFe2O4 ceramic material
- Open Access
- 10 February 2024
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (7) , 2444-2451
Advanced radiation shielding materials: PbO2-doped zirconia ceramics synthesized through innovative sol-gel method
- 10 February 2024
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (7) , 2444-2451
Open AccessAdvanced radiation shielding materials: PbO2-doped zirconia ceramics synthesized through innovative sol-gel method
- Open Access
- 17 November 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (22) , 12456
Zn Doping Improves the Anticancer Efficacy of SnO2 Nanoparticles
Tin dioxide (SnO2) nanoparticles (NPs) can be applied in several ways due to their low cost, high surface-to-volume ratio, facile synthesis, and chemical stability. There is limited research on the biomedical application of SnO2-based nanostructures. This study aimed to investigate the role of Zn doping in relation to the anticancer potential of SnO2 NPs and to enhance the anticancer potential of SnO2 NPs through Z doping. Pure SnO2 and Zn-doped SnO2 NPs (1% and 5%) were prepared using a modified sol–gel route. XRD, TEM, SEM, EDX, UV-Vis, FTIR, and PL techniques were used to characterize the physicochemical properties of produced NPs. XRD analysis revealed that the crystalline size and phase composition of pure SnO2 increased after the addition of Zn. The spherical shape and homogenous distribution of these NPs were confirmed using TEM and SEM techniques. EDX analysis confirmed the Sn, Zn, and O elements in Zn-SnO2 NPs without impurities. Zn doping decreased the band gap energy of SnO2 NPs. The PL study indicated a reduction in the recombination rate of charges (electrons/holes) in SnO2 NPs after Zn doping. In vitro studies showed that the anticancer efficacy of SnO2 NPs increased with increasing levels of Zn doping in breast cancer MCF-7 cells. Moreover, pure and Zn-doped SnO2 NPs showed good cytocompatibility in HUVECs. This study emphasizes the need for additional investigation into the anticancer properties of Zn-SnO2 nanoparticles in various cancer cell lines and appropriate animal models.
- 17 November 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (22) , 12456
Open AccessZn Doping Improves the Anticancer Efficacy of SnO2 Nanoparticles
Tin dioxide (SnO2) nanoparticles (NPs) can be applied in several ways due to their low cost, high surface-to-volume ratio, facile synthesis, and chemical stability. There is limited research on the biomedical application of SnO2-based nanostructures. This study aimed to investigate the role of Zn doping in relation to the anticancer potential of SnO2 NPs and to enhance the anticancer potential of SnO2 NPs through Z doping. Pure SnO2 and Zn-doped SnO2 NPs (1% and 5%) were prepared using a modified sol–gel route. XRD, TEM, SEM, EDX, UV-Vis, FTIR, and PL techniques were used to characterize the physicochemical properties of produced NPs. XRD analysis revealed that the crystalline size and phase composition of pure SnO2 increased after the addition of Zn. The spherical shape and homogenous distribution of these NPs were confirmed using TEM and SEM techniques. EDX analysis confirmed the Sn, Zn, and O elements in Zn-SnO2 NPs without impurities. Zn doping decreased the band gap energy of SnO2 NPs. The PL study indicated a reduction in the recombination rate of charges (electrons/holes) in SnO2 NPs after Zn doping. In vitro studies showed that the anticancer efficacy of SnO2 NPs increased with increasing levels of Zn doping in breast cancer MCF-7 cells. Moreover, pure and Zn-doped SnO2 NPs showed good cytocompatibility in HUVECs. This study emphasizes the need for additional investigation into the anticancer properties of Zn-SnO2 nanoparticles in various cancer cell lines and appropriate animal models.
- Open Access
- 1 August 2023
- Published by Oxford University Press (OUP) in BJR|Open
- Vol. 5 (1) , 20220035
Response evaluation of two commercial thermoluminescence dosimeters (TLDs) against different parameters
Objectives: It is essential to study the dosimetric performance and reliability of personal dosimeters. This study examines and compares the responses of two commercial thermoluminescence dosimeters (TLDs), the TLD-100 and the MTS-N. Methods: We compared the two TLDs to various parameters such as energy dependence, linearity, homogeneity, reproducibility, light sensitivity (zero point), angular dependence, and temperature effects using the IEC 61066 standard. Results: The results acquired showed that both TLD materials show linear behavior as indicated by the quality of the fit. In addition, the angular dependence results for both detectors show that all dose responses are within the range of acceptable values. However, the TLD-100 outperformed the MTS-N in terms of light sensitivity reproducibility for all detectors together, while the MTS-N outperforms the TLD-100 for each detector independently and that showed TLD-100 has more stability than MTS-N. The MTS-N shows better batch homogeneity (10.84%) than TLD-100 (13.65%). The effect of temperature in signal loss was clearer at higher temperature 65°C and it was however below ±30%. Conclusions: The overall results for dosimetric properties determined in terms of dose equivalents for all combinations of detectors are satisfactory. The MTS-N cards have better results in the energy dependence, angular dependency, batch homogeneity and less signal fading, whereas the TLD-100 cards are less sensitive to light and more reproducible. Advances in knowledge: Although previous studies showed several types of comparisons between TLDs, they have used limited parameters and different data analysis. This study has dealt with more comprehensive characterization methods and examinations combining TLD-100 and MTS-N cards.
- 1 August 2023
- Published by Oxford University Press (OUP) in BJR|Open
- Vol. 5 (1) , 20220035
Open AccessResponse evaluation of two commercial thermoluminescence dosimeters (TLDs) against different parameters
Objectives: It is essential to study the dosimetric performance and reliability of personal dosimeters. This study examines and compares the responses of two commercial thermoluminescence dosimeters (TLDs), the TLD-100 and the MTS-N. Methods: We compared the two TLDs to various parameters such as energy dependence, linearity, homogeneity, reproducibility, light sensitivity (zero point), angular dependence, and temperature effects using the IEC 61066 standard. Results: The results acquired showed that both TLD materials show linear behavior as indicated by the quality of the fit. In addition, the angular dependence results for both detectors show that all dose responses are within the range of acceptable values. However, the TLD-100 outperformed the MTS-N in terms of light sensitivity reproducibility for all detectors together, while the MTS-N outperforms the TLD-100 for each detector independently and that showed TLD-100 has more stability than MTS-N. The MTS-N shows better batch homogeneity (10.84%) than TLD-100 (13.65%). The effect of temperature in signal loss was clearer at higher temperature 65°C and it was however below ±30%. Conclusions: The overall results for dosimetric properties determined in terms of dose equivalents for all combinations of detectors are satisfactory. The MTS-N cards have better results in the energy dependence, angular dependency, batch homogeneity and less signal fading, whereas the TLD-100 cards are less sensitive to light and more reproducible. Advances in knowledge: Although previous studies showed several types of comparisons between TLDs, they have used limited parameters and different data analysis. This study has dealt with more comprehensive characterization methods and examinations combining TLD-100 and MTS-N cards.
- Open Access
Comparison of Dosimetry Protocols for Electron Beam Radiotherapy Calibrations and Measurement Uncertainties
This paper presents guidelines for the calibration of radiation beams that were issued by the International Atomic Energy Agency (IAEA TRS 398), the American Association of Physicists in Medicine (AAPM TG 51) and the German task group (DIN 6800-2). These protocols are based on the use of an ionization chamber calibrated in terms of absorbed dose to water in a standard laboratory’s reference quality beam, where the previous protocols were based on air kerma standards. This study aims to determine uncertainties in dosimetry for electron beam radiotherapy using internationally established high-energy radiotherapy beam calibration standards. Methods: Dw was determined in 6-, 12- and 18 MeV electron energies under reference conditions using three cylindrical and two plane-parallel ion chambers in concert with the IAEA TRS 398, AAPM TG 51 and DIN 6800-2 absorbed dose protocols. From mean measured Dw values, the ratio TRS 398/TG 51 was found to vary between 0.988 and 1.004, while for the counterpart TRS 398/DIN 6800-2 and TG 51/DIN 6800-2, the variation ranges were 0.991–1.003 and 0.997–1.005, respectively. For the cylindrical chambers, the relative combined uncertainty (k = 1) in absorbed dose measurements was 1.44%, while for the plane-parallel chambers, it ranged from 1.53 to 1.88%. Conclusions: A high degree of consistency was demonstrated among the three protocols. It is suggested that in the use of the presently determined dose conversion factors across the three protocols, dose intercomparisons can be facilitated between radiotherapy centres.
Open AccessComparison of Dosimetry Protocols for Electron Beam Radiotherapy Calibrations and Measurement Uncertainties
This paper presents guidelines for the calibration of radiation beams that were issued by the International Atomic Energy Agency (IAEA TRS 398), the American Association of Physicists in Medicine (AAPM TG 51) and the German task group (DIN 6800-2). These protocols are based on the use of an ionization chamber calibrated in terms of absorbed dose to water in a standard laboratory’s reference quality beam, where the previous protocols were based on air kerma standards. This study aims to determine uncertainties in dosimetry for electron beam radiotherapy using internationally established high-energy radiotherapy beam calibration standards. Methods: Dw was determined in 6-, 12- and 18 MeV electron energies under reference conditions using three cylindrical and two plane-parallel ion chambers in concert with the IAEA TRS 398, AAPM TG 51 and DIN 6800-2 absorbed dose protocols. From mean measured Dw values, the ratio TRS 398/TG 51 was found to vary between 0.988 and 1.004, while for the counterpart TRS 398/DIN 6800-2 and TG 51/DIN 6800-2, the variation ranges were 0.991–1.003 and 0.997–1.005, respectively. For the cylindrical chambers, the relative combined uncertainty (k = 1) in absorbed dose measurements was 1.44%, while for the plane-parallel chambers, it ranged from 1.53 to 1.88%. Conclusions: A high degree of consistency was demonstrated among the three protocols. It is suggested that in the use of the presently determined dose conversion factors across the three protocols, dose intercomparisons can be facilitated between radiotherapy centres.