Optimization of the linear quantification range of an online trypsin digestion coupled liquid chromatography–tandem mass spectrometry (LC–MS/MS) platform
- 27 April 2017
- journal article
- research article
- Published by Taylor & Francis in Instrumentation Science & Technology
- Vol. 46 (1) , 102-114
Abstract
Tandem mass spectrometry (MS/MS)-based proteomic workflows with a bottom-up approach require enzymatic digestion of proteins to peptide analytes, usually by trypsin. Online coupling of trypsin digestion of proteins, using an immobilized enzyme reactor (IMER), with liquid chromatography (LC) and MS/MS is becoming a frequently used approach. However, finding IMER digestion conditions that allow quantitative analysis of multiple proteins with wide range of endogenous concentration requires optimization of multiple interactive parameters: digestion buffer flow rate, injection volume, sample dilution, and surfactant type/concentration. In this report, we present a design of experiment approach for the optimization of an integrated IMER-LC-MS/MS platform. With bovine serum albumin as a model protein, the digestion efficacy and digestion rate were monitored based on LC-MS/MS peak area count versus protein concentration regression. The optimal parameters were determined through multivariate surface response modeling and consideration of diffusion controlled immobilized enzyme kinetics. The results may provide guidance to other users for the development of quantitative IMER-LC-MS/MS methods for other proteins.Keywords
This publication has 15 references indexed in Scilit:
- Quantification of serum apolipoproteins A-I and B-100 in clinical samples using an automated SISCAPA–MALDI-TOF-MS workflowMethods, 2015
- Quantifying Protein Measurands by Peptide Measurements: Where Do Errors Arise?Journal of Proteome Research, 2015
- Accelerating Trypsin Digestion: The Immobilized Enzyme ReactorBioanalysis, 2014
- Metrological traceability in mass spectrometry-based targeted protein quantitation: A proof-of-principle study for serum apolipoproteins A-I and B100Journal of Proteomics, 2014
- Protein Digestion: An Overview of the Available Techniques and Recent DevelopmentsJournal of Proteome Research, 2013
- Multiple-Reaction Monitoring–Mass Spectrometric Assays Can Accurately Measure the Relative Protein Abundance in Complex MixturesClinical Chemistry, 2012
- A rapid method for cross‐species quantitation of apolipoproteins A1, B48 and B100 in plasma by ultra‐performance liquid chromatography/tandem mass spectrometryRapid Communications in Mass Spectrometry, 2011
- Simultaneous Quantification of Apolipoprotein A-I and Apolipoprotein B by Liquid-Chromatography–Multiple- Reaction–Monitoring Mass SpectrometryClinical Chemistry, 2010
- The application of ultra‐performance liquid chromatography/tandem mass spectrometry to the detection and quantitation of apolipoproteins in human serumRapid Communications in Mass Spectrometry, 2007
- A proteomic study of the apolipoproteins in LDL subclasses in patients with the metabolic syndrome and type 2 diabetesJournal of Lipid Research, 2005